Loading...
HomeMy WebLinkAboutP-206 - 3RD FLOOR SANITARY _ VENT PLAN3 3.1 4 5 I I I I I & — —� I — tI I I I I — — - — — PTAC-1 PTAC-1 CUSTOM Kill J ONE BEDROOM 301 >01 a I -01 1 O7 �I11{�Ifll� U I awl I� III�IBrrriliu I� RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Car�m��ed AVTG'DDBVAWML_��//\\���� X DATE: 07/22/19 6 7 8 9 10 11 12 13 14 15 i6 17 18 100 19 20 21 I I I I I I I I I I I I I I I I (TVP CAL) -302 K I J 1 PTAC-2 PTAC-2 PTAG2 PTAC-2 PTAC-2 t PTAC-1 PTAG7 PTAG7 PTAC-7 PTAC-1 PTAC-1 — — — — — — QUEEN/ ACC. QUE II QUEEN/ _ QUEEN/ _ QUEEN/ QUEEN _ _ QUEEN_ KING STUDIO _ _ _ _ _ _ F STUDIO QUEEN QUEEN QUEEN STUDIO STUDIO KING STUDIO KING STUDIO CONNECTING 77 a -77 3 303 STUDIO STUDIO STUDIO CONNECTING CONNECTING 315 317 319 KING ONE -77 305 307 309 311 313 BE -03 -os -os s-oT -oe os to CONNECTING -02 -09 -� -05 -06 -07 -06 -09 -70 321 -02 03 a -04 05 a 06 a S-17 a -09 a -7O a LAV-07 W -01 NK-01 TORAGE L13 (I FF 331 1 SHR-01 CORR. I I I I I I I I "RD SHR-01 SHRSHR-011 `RD ----- O 4 D _"RD ----- O 4 D 4"RD 4"1 — — — D w p 1 ICE - „I, .. I, 1 Q �irh I I1. I II ' - .11, wK. 1 Icy �I 1 I I�14 IN= BI�IAIIt I. J� � I -- -7` I I 1�' �7 �7 II I' ;i1 m .. ..pSTUDIOSTUDIOpSTUDIOpSTUDIOpELEVATOR � 302 30 I I I I I I I I I I I I I I I I 3 3.1 4 5 6 7 8 9 10 O3RD FLOOR SANITARY & VENT PLAN 1/811 = 11-011 GENERAL NOTES 1 "JOIST OR TRUSS FRAMER TO ADJUST THE TRUSS AND JOIST LOCATIONS AS NEEDED TO AVOID PLUMBING CONFLICTS BUT IN NO WAY TRUSS OR TJI TO BE PLACED WITH A SPACING LARGER THAN SPECIFIED". SANITARY & VENT KEYNOTES (TYPICAL FLOOR) Tag Text 10 CONDENSATE RISER DOWN, SEE LOW ER FLOOR PLANS FOR CONTINUATION. ROUTE EACH CONDENSATE VERTICAL RISER TO CONNECT TO STORM LINE. GC TO COORDINATE CONNECTION & ENSURE SLOPE OF 1/S"FT FOR THE HORIZONTAL RUN OF PIPE. TYPICAL FOR ALL PTAC UNITS CONDENSATE DRAINAGE UNLESS NOTED OTHE RW ISE. BAS E'' BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF/� QP ...s i EH"4 e1` Fo'. 1 12 o ATE a OF roNAL DATE: 2018030/1 OARRY VERMAAe. PhD. HE Owner: r 1: ,,,-14 /W Q� �1 1� �I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.2201fi REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 PO 2019.03.04 ISSUED FOR PERMIT CURRENT ISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SPB CHECKED BY GWV PROJECT NO B4-134-1705 SHEET NAME 3RD FLOOR SANITARY & VENT PLAN DRAWINGS NO. P=206