Loading...
HomeMy WebLinkAboutP-208 - 4TH FLOOR SANITARY _ VENT PLAN1 2 TTT I I T T T T T 0 1TT 4 5 6 17 8 100 1I 19 TT K K (TYP CAL) IFF— — 1 — — — — PI— PTAC-2 PTAC-2 PI PI t y — — — — — — — — — — 7 PTAC-1 III+ PTAC-1 PTAC-1 PTAG1 PTAC-1 PTAC-1 S�2 —Pinc1 — PTAC-1 QUEEN/ _ QUEEN/ _ QUEEN/ QUEEN/ _ CUSTOM CUSTOM KING KING STUDIO QUEEN QUEEN QUEEN QUEEN QUEEN/QUEEN I KINGSTUDIOKINGSTUDIO KING STUDIO JJ ONE STUDIO STUDIO STUDIO STUDIO STUDIO 4� tlEDROOM "RD S03 407 49 44A KING ONE • 006 -07 oe -os -10 BEDROOM O7 a III -O7 02 I -03 -05 -O6 '07 -08 -09 -10 421 YS -01 -02 ti a -0 -OS a -OB a -07 a 09 a 70 a NK-01 WC A R-07 ..� STQRAGEF��Mj TIFF I I „ 431 4 — I = --T —I — IZAV--01 01 — I— — — — — — CORk 1 — 1 — 1 — —1 11 1 — — 1 — —1 �J -3 _ S R-01 _ _ _ _ "RD SHR-01 SHR-07 "RD 400 4" D 4RD 4"RD - ICE M 428 WCL-0 Shi SNK-01 L-0 WC SNK-07 ELE 1 D D 10 27 a 20 a 78 a ELECTRICA 76 a -74 a 72 a U — I — 22 — 1 — — — — r — -78 -75 -74 -73 72 KIN -01 22 21 20 5-1 18 -17 ah fLE'bHf 429 78 -75 -74 5-73 -72 I 103 ST4S #1 CUS OM KING KING STUDIO KING STUDIO KING STUDIO KING STUDIO KING STUDIO ELEVATOR KING STUDIO KING STUDIO KING STUDIO KING STUDIO KINGSTUDIO — — �S LABBa` H USEKEEPING0»�»I 1 4 0 1 1 — � — PTAC-2 _ PTAG7 Pi— PTAG7 — PTAG1 — —PTAC-1 — PTAC-1 _ PTAG7 — PTAC-1 PI— PI_ A.1 A 7 - __ -T- - rT A�--' 302 (TYP CAL) `--�� I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 2 3 3.1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 100 19 20 21 O4TH FLOOR SANITARY& VENT PLAN 1/811 = 11.011 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City Bf Camel AM�G'U \n' x DATE: 07/22/19 GENERALNOTES 1 "JOIST OR TRUSS FRAM ER TO ADJ UST TH E TRUSS AN D JOIST LOCATIONS AS N EED ED TO AVOID PLUMBING CONFLICTS BUT IN NO WAY TRUSS OR TJI TO BE PLACED WITH A SPACING LARGER THAN SPECIFIED". SANITARY & VENT KEYNOTES (TYPICAL FLOOR) Tag Text 1v CONDENSATE RISER DOWN, SEE LOWER FLOOR PLANS FOR CONTINUATION. ROUTE EACH CONDENSATE VERTICAL RISER TO CONNECT TO STORM LINE. GC TO COORDINATE CONNECTION & ENSURE SLOPE OF 1/8"FT FOR THE HORIZONTAL RUN OF PIPE. TYPICAL FOR ALL PTAC UNITS CONDENSATE DRAINAGE UNLESS NOTED OTHERWISE. BAS E4 BASE4 2901 CLINT MOORE ROAD, #114 BOCA RATON, FLORIDA 33496 888.901.8008 www.base-4.com RICARDO J. MUNIZ-GUILLET, AIA 5453 NW 106TH DR CORAL SPRINGS, FL 33076 MEP ENGINEER GARRY VERMAAS PhD, PE 2183 S BERRYS CHAPEL ROAD FRANKLIN, TN 37069 Seal: 1 W VF QP��'\si EHh� 1 12 o ATE OF s& oNAL DATE: 20180300 GARRY WIJA .PhD. PE Owner: 1�11 ri� �I THE WITNESS GROUP 600 ENTERPRISES DRIVE LEWIS CENTER,OH 513-623-9430 HOME©SUITES BY HILTON CARMEL, INDIANA PROTOTYPE VERSION-V2.22016 REVISION: MAY 2016 ISSUE NO.1 DELTA I ISSUED DATE I DESCRIPTION 1 PO 2019.03.04 ISSUED FOR PERMIT CURRENTISSUE ISSUED FOR PERMIT CURRENT ISSUE DATE 2019.03.04 DRAWN BY SPB CHECKED BY GWV PROJECT NO, 134-134-1705 SHEET NAME 4TH FLOOR SANITARY & VENT PLAN DRAWINGS NO. P=208