HomeMy WebLinkAboutS-101 - INDEX AND STRUCTURAL NOTESDRAWING LIST
SHEET
DESCRIPTION
SET
DATE
S-101
INDEX AND STRUCTURAL NOTES
ISSUED FOR PERMIT
2019.03.04
S-102
STRUCTURAL NOTES(CONT.)
ISSUED FOR PERMIT
2019.03.04
S-103
SCHEDULES
ISSUED FOR PERMIT
2019.03.04
S-104
SCHEDULES (CONT.)
ISSUED FOR PERMIT
2019.03.04
S-105
SCHEDULES (CONT.)
ISSUED FOR PERMIT
2019.03.04
S-201.1
FOUNDATION PLAN
ISSUED FOR PERMIT
2019.03.04
S-201.2
1ST FLOOR WALL AND COLUMN PLAN
ISSUED FOR PERMIT
2019.03.04
S-202.1
2ND FLOOR STEEL FRAMING PLAN
ISSUED FOR PERMIT
2019.03.04
S-202.2
2ND FLOOR FRAMING PLAN
ISSUED FOR PERMIT
2019.03.04
S-202.2A
PRECAST PLANK LOADING PLAN
ISSUED FOR PERMIT
2019.03.04
S-202.3
2ND FLOOR WALL AND COLUMN PLAN
ISSUED FOR PERMIT
2019.03.04
S-203.1
3RD FLOOR FRAMING PLAN
ISSUED FOR PERMIT
2019.03.04
S-203.2
3RD FLOOR WALL AND COLUMN PLAN
ISSUED FOR PERMIT
2019.03.04
S-204.1
4TH FLOOR FRAMING PLAN
ISSUED FOR PERMIT
2019.03.04
S-204.2
4TH FLOOR WALL AND COLUMN PLAN
ISSUED FOR PERMIT
2019.03.04
S-205.1
5TH FLOOR FRAMING PLAN
ISSUED FOR PERMIT
2019.03.04
S-205.2
5TH FLOOR WALL AND COLUMN PLAN
ISSUED FOR PERMIT
2019.03.04
S-206.1
ROOF FRAM ING PLAN
ISSUED FOR PERMIT
2019.03.04
S-206.2
ROOF PARAPET PLAN
ISSUED FOR PERMIT
2019.03.04
S-207
ROOF COMPONENT & CLADDING
ISSUED FOR PERMIT
2019.03.04
S-301
WINDOW& DOOR WIND PRESSURE
ISSUED FOR PERMIT
2019.03.04
S-302
WINDOW& DOOR WIND PRESSURE
ISSUED FOR PERMIT
2019.03.04
S401
BUILDING SECTION
ISSUED FOR PERMIT
2019.03.04
S402
BUILDING SECTION
ISSUED FOR PERMIT
2019.03.04
S-501
WALL SECTION
ISSUED FOR PERMIT
2019.03.04
S-502
CANOPY AND TRELLIS DETAIL
ISSUED FOR PERMIT
2019.03.04
S-601
TYPICAL DETAILS
ISSUED FOR PERMIT
2019.03.04
SE03
TYPICAL DETAILS
ISSUED FOR PERMIT
2019.03.04
S-604
TYPICAL DETAILS
ISSUED FOR PERMIT
2019.03.04
5805
TYPICAL DETAILS
ISSUED FOR PERMIT
2019.03.04
LEGEND
+ CONCRETE STEM WALL
ICF STEM WALL
WOOD SHEAR WALL
WOOD BEAR WALL
CMU WALL
ICF WALL
PARAPETWALL
0 WALL OPENING BELOW
DETAIL NUMBER
S# S
SHEET ON WHICH
DETAIL IS SHOWN
SHEET ON WHICH
DETAIL IS CALLED OUT
SECTION LETTER
S# SHEET WHICH
SECTIONN ISIS SHOWN
�# COLUMN AT OR ABOVE FLOOR LEVEL
® FOOTING TYPE
ARCH
AFF.
ALUM
A.O.R
BM.
BOTT.
BP.
BRG.
BILK
BFE.
BW.
CLR.
C&C.
CONIC
COL.
CONN
CMU.
CJ.
CL.
CONT.
D IA.
DWG.
DEC.
DIM.
D.L.
ELEV.
EA.
EMBED PL
ELEC.
EQ.
EXP.
EXT.
EJ.
E.O.R.
FTG.
FLR.
FIN.
GA.
GALV.
GT.
HORIZ.
HWS.
CONCRETE BEAM
r a . CMU COLUMN
CONCRETE COLUMN
0 STEEL COLUMN
FLOOROPENING
Ao REVISION NUMBER
MOMENT CONNECTION
`��� PINNED (NON -MOMENT
CONNECTION REVISION NUMBER
OCOLUMN THROUGH FLOOR LEVEL
# 1 COLUMN BELOW FLOOR LEVEL
ABBREVIATIONS
ARCHITECTURAL
ABOVE FINISHED FLOOR
ALUMINUM
ARCHITECT OF RECORD
BEAM
BOTTOM
BASE PLATE
BEARING
BLOCK
BASE FLOOR ELEVATION
BEAR WALL
CLEAR
COMPONENTS AND CLADDING
CONCRETE
COLUMN
CONNECTION
CONCRETE MASONRY UNIT
CONTROL JOINT
CENTER LINE
CONTINUOUS
DIAMETER
DRAWING
DEGREES
DIMENSION
DEAD LOAD
ELEVATION
EACH
EMBED PLATE
ELECTRICAL
EQUAL
EXPANSION
EXTERIOR
EXPANSION JOINT
ENGINEER OF RECORD
FOOTING
FLOOR
FINISH
GAUGE
GALVANIZED
GIRDER TRUSS
HORIZONTAL
HEADED WELDING STUD
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
x
DATE: 07/22/19
FINISH FLOOR LEVEL
STRUCTURAL LEVEL
IN. INCH
LONG. LONGITUDINAL
L.L. LIVE LOAD
MIN.
MINIMUM
MAX.
MAXIMUM
MONO.
MONOLITHIC
MTL.
METAL
Ml
MANUFACTURER
NO. NUMBER
N.T.S. NOT TO SCALE
NOM. NOMINAL
O.C. ON CENTER
OH OVERHEAD
PL. PLATE
RCC.
REINFORCED CEMENT
CONCRETE
REINF.
REINFORCING
REQ.
REQUIRED
REF.
REFERENCE
REV.
REVISED (REVISION)
S.O.G.
SLAB -ON -GRADE
SEOR.
STRUCTURAL ENGINEER OF
RECORD
STD.
STANDARD
SIM.
SIMILAR
SEC.
SECTION
SPEC.
SPECIFICATIONS
STRUCT.
STRUCTURAL
STL.
STEEL
SW,
SHEAR WALL
T.O.
TOP OF
TYP.
TYPICAL
TRANS.
TRANSVERSE
THK.
THICKNESS
T/SLAB.
TOP OF SLAB
RMIKO�lP14111 911011A10A :ie
17q:7�7q:71[NA�
W/
WITH
W.W.F.
WELDED WIRE FABRIC
WB.
WOOD BEAM
W.L.
WIND LOAD
1 MIL. 1/1000 INCH
STRUCTURAL NOTES AND SPECIFICATIONS
MEAN ROOF HEIGHT
55'-111/2"
NUMBER OF STORIES (PARTIAL UNDERGROUND)
5(0)
FOUNDATION TYPE
TRENCH FOOTING
(STEM WALL)
FLOOR SYSTEM (2ND FLOOR)
HOLLOW CORE PLANK
(3RD TO 5TH FLOOR)
24" DEEP OPEN WEB TRUSS
ROOF SYSTEM (ROOF)
30" DEEP OPEN WEB TRUSS
DESIGN LOADS
DEAD LOAD
THE FOLLOWING SUPERIMPOSED DEAD LOADS (SELFWEIGHT INCLUDED)
ROOF (OVER GUEST ROOM)
22 PSF.
ROOF (OVER CORRIDOR AND COMMON AREA)
23 PSF.
ROOM (TYPICAL FLOOR)
27 PSF.
ROOM (2ND FLOOR)
106 PSF.
CORRIDOR AND COMMON AREA (TYPICAL FLOOR)
28 PSF.
STAIR
90 PSF.
LIVE LOAD
THE FOLLOWING LIVE LOADS HAVE BEEN UTILIZED
FLOOR
i) ROOM
40 PSF.
it) CORRIDORS SERVING PUBLIC ROOM
100 PSF.
in) LAUNDRY
100 PSF.
IV) STORAGE
125 PSF.
Y) MECHANICAL
125 PSF.
VI) ELECTRICAL
125 PSF.
ROOF
20 PSF.
STAIR
100 PSF.
CORRIDORS
40 PSF.
ELEVATOR MACHINE ROOM
150 PSF.
ELEVATOR LOBBY
100 PSF.
HOUSE KEEPING
100 PSF.
ICE ROOM
150 PSF.
P11111l1a[•E?
THE FOLLOWING WIND LOAD DESIGN PARAMETERS HAVE BEEN UTILIZED:
ALL STRUCTURAL ELEMENTS, EXPOSED TO WIND, HAVE BEEN DESIGNED PER THE GUIDELINES OF THE
ASCE 7-10 BUILDING CODE WITH THE FOLLOWING DESIGN VALUES:
WIND SPEED 115MPH
EXPOSURE C
RISK CATEGORY (ASCE 7-10) II
Kid 0.85 FOR MWFRS
Kid 0.85 FOR C&C
INTERNAL PRESSURE COEFFICIENTS(ENCLOSED) f0.18
ZONE 5
ZONE M aE&
ON`Oa
- ZONE 5
W IDTH OF PRESSURE COEFFICIENT ZONE, a: 7'-4"
VERTICAL PRESSURE FOR ZONE 4&5 FOR MINIMAL AREA 10SF = 69.67 PSF
FLAT ROOF
SEISMIC LOAD
THE FOLLOWING SEISMIC LOAD DESIGN PARAMETERS HAVE BEEN UTILIZED:
OCCUPANCY CATEGORY II
SPECTRAL RESPONSE ACCELERATION AT PERIOD OF SHORT PERIODS(Ss) 0.147g
SPECTRAL RESPONSE ACCELERATION AT PERIOD OF I-SEC(Si) 0.082g
SPECTRAL RESPONSE COEFFICIENT (Sds) 0.118g
SPECTRAL RESPONSE COEFFICIENT (Sol) 0.092g
SITE CLASS C
SEISMIC DESIGN CATEGORY B
SEISMIC IMPORTANCE FACTOR(le) 1.0
BASIC SEISMIC -FORCE -RESISTING SYSTEM LIGHT FRAMED WALLS SHEATED
WITH WOOD STRUCTURAL
PANELS ABOVE WITH ORDINARY
REINF. CON. SHEAR WALLS AT
GROUND FLOOR
DESIGN BASE SHEAR 309 KIPS
ANALYSIS PROCEDURE EQUIVALENT LATERAL
LATERAL PROCEDURE
RESPONSE MODIFICATION COEFFICIENT 2
LONG PERIOD TRANSITION PERIOD 12 SEC
SNOW LOAD
THE FOLLOWING SNOW LOADS HAVE BEEN UTILIZED:
GROUND SNOW LOAD (Pg) 20 PSF.
FLAT ROOF SNOW LOADS(Pi 12.6 PSF.
SNOW EXPOSURE FACTOR (08) 0.9
SNOW IMPORTANCE FACTOR (Is) 1.0
THERMAL FACTOR(CI) 1.0
GOVERNING CODES
2014 INDIANA BUILDING CODE (IBC2012)
ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
ACI 318 -11 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY
ACI 530 -11 BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES
AISC 360 - 10 EDITION _RFD - MANUAL OF STEEL CONSTRUCTION LOAD & RESISTANCE FACTOR DESIGN
NDS 2012 NATION DESIGN SPECIFICATION FOR WOOD CONSTRUCTION ALLOWABLE STRESS DESIGN
STEEL DECK INSTITUTE DIAPHRAGM DESIGN MANUAL SECOND EDITION
AISI-2007 NORTH AMERICAN SPECIFICATION FOR THE DESIGN COLD -FORMED STEEL STRUCTURAL MEMBERS
GENERAL NOTES
TO THE BEST OF OUR KNOWLEDGE, THE STRUCTURAL DRAWINGS AND SPECIFICATIONS COMPLY WITH THE
APPLICABLE REQUIREMENTS OF THE GOVERNING STATE AND LOCAL BUILDING CODES.
CONSTRUCTION IS TO COMPLY WITH THE REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ALL OTHER
APPLICABLE FEDERAL, STATE AND LOCAL CODES, STANDARDS, ORDINANCES REGULATIONS AND LAWS.
ALL INFORMATION CONTAINED IN THE DIGITAL FILES OR COPIES OF THE STRUCTURAL DRAWINGS ARE
INSTRUMENTS OF SERVICE OF THE ARCHITECT/ENGINEER AND SHALL NOT BE USED FOR OTHER PROJECTS,
ADDITIONS TO THE PROJECT OR THE COMPLETION OF THIS PROJECT BY OTHERS WITHOUT THE EXPRESSED
WRITTEN CONSENT OF THE SEOR.
DIG ITAL FILES AND COPIES OF THE STRUCTURAL DRAWINGS REMAIN THE PROPERTY OF THE SEOR AND IN NO
CASE SHALL THEIR TRANSFER BE CONSIDERED A SALE.
DIGITAL FILES OR COPIES OF THE STRUCTURAL DRAWINGS ARE NOT CONTRACT DOCUMENTS.
WITH ARCHITECTURAL DRAWINGS BEFORE COMMENCING CONSTRUCTION.
TO VERIFY DIMENSIONS, LOCATIONS OF DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, BOLT
SETTINGS SLEEVES ETC. STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH ARCHITECTURAL,
MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS.
DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY.
DIMENSIONS IN THE DIGITAL FILES MAY NOT BE ALTERED FOR PRESENTATION PURPOSES.
IN THE EVENT OF A CONFLICT, NOTIFY THE SEOR.
ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE
CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A
DIFFERENT DETAIL IS SHOWN.
VERIFY ALL DIMENSIONS, ELEVATIONS, SIZE AND LOCATION OF WALL OPENINGS, COLUMNS AND SLAB FINISHES
ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL OR PLUMBING EQUIPMENT
SHALL BE VERIFIED WITH EQUIPMENT PURCHASED BEFORE PROCEEDING WITH STRUCTURAL WORK AFFECTED.
PENETRATIONS OF ANY STRUCTURAL MEMBER NOT SHOWN ON THE STRUCTURAL DRAWINGS WILL NOT BE
ALLOWED W ITHOUT W RITTEN APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD. CONTRACTOR SHALL
SUBMIT TO THE STRUCTURAL ENGINEER FOR APPROVAL A DRAWING DETAILING THE OPENING LOCATIONS AND
SIZE PRIOR TO CONSTRUCTION.
CHANGES TO THE SIZE OR LOCATION OF STRUCTURAL MEMBERS WITHOUT WRITTEN INSTRUCTIONS FROM THE
STRUCTURAL ENGINEER OF RECORD IS PROHIBITED.
SEE PROJECT SPECIFICATIONS (WHEN APPLICABLE) FOR TESTING.
CONTRACTOR RESPONSIBILITIES
CONTRACTOR SHALL OBTAIN LATEST SET OF DRAWINGS INCLUDING ANY REVISIONS BEFORE STARTING
CONSTRUCTION.
IT IS ASSUMED THATTHE CONTRACTOR HAS READ AND UNDERSTANDS THE NOTES AND DESIGN INTENT
CONTAINED HEREIN.
THE CONTRACTOR SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE STARTING WORK.
THE CONTRACTOR SHALLACCEPT FULL RESPONSIBILITY FOR ANY ERRORS OR OMISSIONS NOT REPORTED
IMMEDIATELY IN WRITING TO THIS ENGINEER.
CONTRACTORS WHO DISCOVER DISCREPANCIES, OMISSIONS OR VARIATIONS IN THE CONTRACT
DOCUMENTS DURING BIDDING SHALL IMMEDIATELY NOTIFY THE SEOR. THE SEOR WILL RESOLVE THE
CONDITION AND ISSUE A WRITTEN CLARIFICATION.
ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER IN WRITING
PRIOR TO PROCEEDING WITH THE AFFECTED PART OF THE WORK.
THE FRANCHISE BRAND STANDARDS DESIGN DOCUMENT SHALL BE CONSIDER AS AN INTEGRAL PART OF
THE CONSTRUCTION DOCUMENTS CONTRACTORS SHALL ENSURE THEY OBTAIN, READ AND FAMILIARIZE
THEMSELVES WITH THE BRAND STANDARD DOCUMENT BEFORE BIDDING AND ALSO THROUGHOUT THE
CONSTRUCTION STAGES. IF THERE ARE ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS
AND THE FRANCHISE BRAND STANDARDS. THE CONTRACTOR SHALL ISSUE AN RFI TO THE AOR AND EOR.
THE GENERAL CONTRACTOR SHALL COORDINATE ALL CONTRACT DOCUMENTS WITH FIELD
CONDITIONS/DIMENSIONS AND PROJECT SHOP DRAWINGS PRIOR TO CONSTRUCTION.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS AND JOBSITE
SAFETY INCLUDING ALL OSHA REQUIREMENTS.
THE CONTRACTOR SHALL PROTECTADJACENT PROPERTY, HIS OWN WORK AND THE PUBLIC FROM HARM.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO
INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS WORK INCLUDES THE
ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOW NS. WHEREVER
THE CONTRACTOR IS UNSURE OF THESE REQUIREMENTS, THE CONTRACTOR SHALL RETAIN A QUALIFIED
STATE LICENSED PROFESSIONAL ENGINEER TO DESIGN AND INSPECT THE TEMPORARY BRACING AND
STABILITY OF THE STRUCTURE.
THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE.
PRIOR TO COMPLETION, THE RESPONSIBILITY FOR STABILITY AND TEMPORARY BRACING IS THE
RESPONSIBILITY OF THE CONTRACTOR.
THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
REQUIREMENTS (INCLUDING SLAB -ON -GRADE THICKNESS) TO HANDLE CONSTRUCTION LOADS.
THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL EXCAVATION AND SHORING
PROCEDURES AND PROTECTION OF ADJACENT PROPERTY, STREETS AND UTILITIES IN ACCORDANCE WITH
LOCAL BUILDING DEPARTMENT.
WHEN PERFORMING WORK BELOW GRADE, CARE SHALL BE TAKEN TO AVOID DAMAGING ANY EXISTING
UTILITIES.
ALL UNKNOWN UTILITIES DISCOVERED DURING CONSTRUCTION SHALL BE BROUGHT TO THE ATTENTION OF
THE ARCHITECT. ANY DAMAGE TO THE EXISTING UTILITIES SHALL BE IMMEDIATELY REPORTED TO ALL
AFFECTED PARTIES INCLUDING THE ARCHITECT.
SHOP DRAWINGS AND OTHER SUBMITTALS
CONSULT WITH THE DESIGN PROFESSIONAL CONTRACT FOR SUBMITTALS TO BE REVIEWED. ITEMS
NOT SPECIFICALLY INCLUDED IN SAID CONTRACT W ILL NOT BE REVIEWED.
THE STRUCTURAL FRAMING SHOWN IS SCHEMATIC IN NATURE. THE SUPPORTING STRUCTURE HAS
BEEN DESIGNED UNDER THE ASSUMPTION THAT THE FRAMING SCHEME SHOWN WILL CLOSELY
PARALLEL FINAL SUPERSTRUCTURE LAYOUT.
THE CONTRACTOR SHALL PROVIDE SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS
(PREPARED BY A QUALIFIED STATE LICENSED PROFESSIONAL ENGINEER) FOR APPROVAL PRIOR TO
RELEASE FOR FABRICATION.
THE REVIEW OF SHOP DRAWINGS IS REQUIRED AS THE ENGINEER CHECKS BEAM, WALL, COLUMN AND
FOOTING CAPACITIES AGAINST KNOWN LOADING. FAILURE TO PROVIDE SHOP DRAWINGS PRIOR TO
FABRICATION OR CONSTRUCTION OF SUPPORTING ELEMENTS MAY RESULT IN ADDITIONAL
ENGINEERING COSTS DURING CONSTRUCTION.
THE CONTRACTOR SHALL SUPPLY THE ENGINEER WITH DIGITAL COPIES OF THE COMPLETE SHOP
DRAWING AND CALCULATION SUBMITTAL WITH THE UNDERSTANDING THAT UP TO (5) BUSINESS DAYS
ARE NECESSARY FOR THE REVIEW PERIOD.
SUBMIT SPECIFIC COMPONENTS, SUCH AS COLUMNS, FOOTINGS ETC, IN A SINGLE PACKAGE. SUBMIT
SIMILAR FLOORS TOGETHER.
ON THE FIRST SUBMITTAL, CLEARLY FLAG AND CLOUD ALL DIFFERENCES FROM THE CONTRACT
DOCUMENTS
ON RESUBMIT, FLAG AND CLOUD ALL CHANGES AND ADDITIONS TO PREVIOUS SUBMITTAL; ONLY
CLOUDED ITEMS WILL BE REVIEWED.
SUBMITTALS FOR SPECIAL STRUCTURAL LOAD -CARRYING ITEMS THATARE REQUIRED BY CODES OR
STANDARDS TO RESIST FORCES MUST BE PREPARED BY, OR UNDER THE DIRECT SUPERVISION OF A
DELEGATED QUALIFIED STATE LICENSED PROFESSIONAL ENGINEER. EXAMPLES INCLUDE PRE-
ENGINEERED ROOF AND FLOOR TRUSSES, PRECAST CONCRETE, OPEN WEB STEEL JOISTS, EXTERIOR
ENCLOSURE SYSTEMS AND SHORING AND RESHORING.
A DELEGATED ENGINEER IS DEFINED AS A QUALIFIED STATE LICENSED PROFESSIONAL ENGINEER
WHO SPECIALIZES IN AND UNDERTAKES THE DESIGN OF STRUCTURAL COMPONENTS OR STRUCTURAL
SYSTEMS INCLUDED IN A SPECIFIC SUBMITTAL PREPARED FOR THIS PROJECT AND IS AN EMPLOYEE
OR OFFICER OF OR CONSULTANT TO. THE CONTRACTOR OR FABRICATOR RESPONSIBLE FOR THE
SUBMITTAL. THE DELEGATED ENGINEER SHALL SIGN, SEAL AND DATE THE SUBMITTAL, INCLUDING
CALCULATIONS AND DRAWINGS.
THE TRADE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT
THE JOB SITES, FOR TOLERANCES, CLEARANCES, QUANTITIES, FABRICATION PROCESSES AND
TECHNIQUES OF CONSTRUCTION, COORDINATION OF THE WORK WITH OTHER TRADES AND FULL
COMPLIANCE WITH THE CONTRACT DOCUMENTS.
THE GENERAL CONTRACTOR/CONSTRUCTION MANAGER SHALL REVIEW AND APPROVE SUBMITTALS
AND SHALL SIGN AND DATE EACH DRAWING PRIOR TO SUBMITTING TO THE SEOR. THIS APPROVAL IS
TO CONFIRM THAT THE SUBMITTAL IS COMPLETE, COMPLIES WITH THE SUBMITTAL REQUIREMENTS
AND IS COORDINATED WITH FIELD DIMENSIONS, OTHER TRADES, ERECTION SEQUENCING AND
CONTRACTIBILITY.
THE STRUCTURAL ENGINEER REVIEWS SUBMITTALS TO CONFIRM THAT THE SUBMITTAL IS IN
GENERAL CONFORMANCE WITH THE DESIGN CONCEPT PRESENTED IN THE CONTRACT DOCUMENTS.
QUANTITIES AND DIMENSIONS ARE NOT CHECKED. NOTATIONS ON SUBMITTALS DO NOT AUTHORIZE
CHANGES TO THE CONTRACT SUM. CHECKING OF THE SUBMITTAL BY THE STRUCTURAL ENGINEER
SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR DEVIATIONS FROM THE CONTRACT
DOCUMENTS AND FROM ERRORS OR OMISSIONS IN THE SUBMITTAL.
IN ADDITION TO THE ABOVE, THE STRUCTURAL ENGINEER'S REVIEW OF THE DELEGATED ENGINEER
SUBMITTALS IS LIMITED TO VERIFYING THAT THE SPECIFIED STRUCTURAL SUBMITTAL HAS BEEN
FURNISHED, SIGNED AND SEALED BY THE DELEGATED ENGINEER AND THAT THE DELEGATED
ENGINEER HAS UNDERSTOOD THE DESIGN INTENT AND USED THE SPECIFIED STRUCTURAL CRITERIA
AND SOUND ENGINEERING JUDGEMENT IN PREPARATION OF THE SUBMITTAL. NO DETAILED CHECK
OF CALCULATIONS WILL BE MADE. THE DELEGATED ENGINEER IS SOLELY RESPONSIBLE FOR HIS/HER
DESIGN, INCLUDING BUT NOT LIMITED TO THE ACCURACY OF HIS/HER CALCULATIONS AND
COMPLIANCE WITH THE APPLICABLE CODES AND STANDARDS.
THE USE OF DIGITAL FILES OR COPIES OF THE STRUCTURAL DRAWINGS SHALL NOT IN ANY WAY
RELIEVE THE CONTRACTOR'S RESPONSIBILITY FOR PROPER CHECKING AND COORDINATION OF
DIMENSIONS, DETAILS, SIZES AND QUANTITIES OF MATERIALS AS REQUIRED FOR THE PREPARATION
OF COMPLETE AND ACCURATE SHOP DRAWINGS.
THE CONTRACTOR SHALL REVISE REFERENCES TO CONTRACT DOCUMENT SHEET NUMBERS AND
SECTION MARKS AND SHALL REMOVE INFORMATION THAT IS NOT REQUIRED FOR THEIR WORK FROM
THE DIGITAL FILES OR COPIES OF THE STRUCTURAL DRAWINGS, INCLUDING THE TITLE BLOCK.
EXCAVATION AND BACKFILL
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING
LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND
UTILITIES IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT AND
OSHA REGULATIONS.
DO NOT EXCAVATE WITHIN ONE FOOT OF THE ANGLE OF REPOSE OF ANY SOIL BEARING FOUNDATION
UNLESS THE FOUNDATION IS PROPERLY PROTECTED AGAINST SETTLEMENT.
DO NOT BACKFILL AGAINSTANY FOUNDATION WALL UNTIL 7 DAYS AFTER THE WALLS ARE BRACED BY
THE STRUCTURE OR ARE TEMPORARILY BRACED.
DO NOT BACKFILL CANTILEVERED RETAINING WALLS UNTIL CONCRETE REACHES 75% OF THE
SPECIFIED 28 DAY STRENGTH.
DO NOT BACKFILL UNTIL COMPLETION OF INSTALLATION AND INSPECTION OF ANY WATERPROOFING.
VAPOR BARRIER
WATERPROOF MEMBRANES (OVERLAPPED 6" AT JOINTS) WITH A PERMEANCE OF LESS THAN 0.3
PERMS IN ACCORDANCE WITH ASTM E-96 SHALL BE PROVIDED UNDER INTERIOR SLABS.
NO FREE WATER STANDING ON EITHER THE SUBGRADE OR ANY MUDDY OR SOFT SPOT IS ALLOWED.
ANY STRUCTURAL MEMBER PENETRATING SLAB ON GRADE IS TO BE ISOLATED WITH 1/2" THICK PRE -
MOLDED JOINT FILLER COMPLYING WITH ASTM D-1752, TYPE 1.
FOR INTERIOR SLABS PLACE 6 MIL POLYETHYLENE SHEATHING BETWEEN SOIL AND BOTTOM OF SLAB.
SHEETING IS NOT REQUIRED BELOW EXTERIOR CONCRETE SLABS.
SLABS ON GRADE
REFER TO GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION MORE THAN 12" BELOW THE
BOTTOM OF THE SLAB.
ABOVE SUBGRADE, USE FILL CONTAINING NOT MORE THAN 10 % PASSING 200 SIEVE AND MAXIMUM 1
INCH DIAMETER.
FILL SHALL BE COMPACTED TO 95 % OF MAXIMUM DRY DENSITY AS DETERMINED BY MODIFIED
PROCTOR ASTM D-1557.
EACH LAYER OF FILL SHALL NOT EXCEED 6" LOOSE THICKNESS. COMPACT PRIOR TO PLACEMENT OF
THE NEXT LAYER. FILL PLACEMENTAND COMPACTION SHALL BE MONITORED AND ACCEPTED BY THE
TESTING AGENCY.
TAKE A MINIMUM OF ONE FIELD DENSITY TEST (ASTM D-1556 OR D-2922) FOR EACH 2,500 SQUARE
FEET OF EACH LAYER. THE TESTING AGENCY SHALL RANDOMLY SELECT TEST LOCATIONS.
USE 4" THICK SLABS ON GRADE REINFORCED WITH 6 X 6 / 10 X 10 WELDED WIRE REINFORCEMENT
SUPPLIED IN FLAT SHEETS ONLY. USE CHAIRS TO SUPPORT WIRE FABRIC IN THE CENTER OF SLAB.
PLACE CONCRETE IN LONG -STRIP CONSTRUCTION METHOD. PROVIDE CRACK CONTROL JOINTS AT 10
FEET MAXIMUM TO LIMITAREAS BETWEEN JOINTS TO 100 SQ. FT. IN ALL FLOATING SLABS ON GRADE.
LOCATE TO CONFORM TO BAY SPACING WHENEVER POSSIBLE, ADD CRACK CONTROL JOINTS AT RE-
ENTRANT CORNERS WHICH TEND TO INVITE CRACKS.
IN SIDEWALKS AND WALKWAYS, LOCATE ISOLATION JOINTS AT 20 FT. O.C. MAXIMUM SCORE AND
TOOL BETWEEN ISOLATION JOINTS IN EQUAL BAYS OF 5 FT. OR LESS.
SEE THE ARCHITECTURAL DRAWINGS FOR SLAB ON GRADE DEPRESSIONS AND OTHER
REQUIREMENTS.
CONTRACTION, EXPANSION AND CONSTRUCTION JOINTS
ALL JOINT PLANS ARE CONSIDERED MEANS AND METHODS AND THE CONTRACTOR SHALL SUBMIT JOINT
PLANS TO THE SEOR FOR APPROVAL.
CONTRACTION JOINTS (ALSO KNOWN AS CONTROL JOINTS) ARE INTENDED TO CREATE WEAKENED
PLANES IN THE CONCRETE AND REGULATE THE LOCATION OF CRACKS.
THE MAXIMUM JOINT SPACING SHOULD BE 24 TO 36 TIMES THE THICKNESS OF THE SLAB NOT
EXCEEDING 15 FEET.
ALL PANELS SHOULD BE SQUARE OR NEARLY SQUARE. THE LENGTH SHOULD NOT EXCEED 1.5 TIMES
THE WIDTH. AVOID L-SHAPED PANELS.
FOR CONTRACTION JOINTS, THE JOINT GROOVE SHOULD HAVE A MINIMUM DEPTH OF 1/4 THE
THICKNESS OF THE SLAB, BUT NOT LESS THAN 1 INCH.
CONVENTIONAL SAW -CUT JOINTS SHOULD BE RUN WITHIN 4 TO 12 HOURS AFTER THE CONCRETE HAS
BEEN FINISHED.
EXPANSION JOINTS (ALSO KNOWN AS ISOLATION JOINTS) SEPARATE SLABS FROM OTHER PARTS OF THE
STRUCTURE.
USE PREMOLDED JOINT FILLER FOR ISOLATION JOINTS TO SEPARATE SLABS FROM BUILDING WALLS OR
FOOTINGS.
TO ISOLATE COLUMNS FROM SLABS, FORM CIRCULAR OR SQUARE RECESS, DO NOT FILL RECESSES
UNTIL AFTER THE FLOOR HAS HARDENED.
CONSTRUCTION JOINTS (ALSO KNOWN AS COLD JOINTS) ARE SURFACES WHERE TWO SUCCESSIVE
PLACEMENTS OF CONCRETE MEET.
CONSTRUCTION JOINTS ARE NOT PERMITTED UNLESS THE DETAIL HAS BEEN APPROVED BY THE SEOR.
CONCRETE DESIGN HAS BEEN PERFORMED IN ACCORDANCE WITH ACI 318 BUILDING CODE REQUIREMENTS
FOR STRUCTURAL CONCRETE.
CONCRETE CONSTRUCTION TECHNIQUES SHALL CONFORM TO THE "SPECIFICATIONS FOR STRUCTURAL
CONCRETE FOR BUILDINGS" (ACI 301).
WHEN APPLICABLE (INCLUDED IN THE DESIGN CONTRACT), CONTRACTOR SHALL SUBMIT PROPOSED MIX
DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT.
CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 301 AND ASTM C-94 FOR MEASURING,
MIXING, TRANSPORTING ETC.
THE OWNER SHALL CONTRACT AN INDEPENDENT TESTING LABORATORY TO PERFORM CONCRETE
CYLINDER TESTS AS FOLLOWS: FOUR CYLINDER TESTS FOR ANY 50 CUBIC YARDS OF CONCRETE POURED,
OR THREE CYLINDER TEST PER ANY DAYS POUR LESS THAN 50 CUBIC YARDS. ONE CYLINDER SHALL BE
TESTED AT 7 DAYS AND TWO AT 28 DAYS.
Am
BASE 4
BASE4
2901 CLINT MOORE ROAD, #114
BOCA RATON, FLORIDA 33496
888.901.8008 www.base4mm
RICARDO J. MUNIZ-GUILLET,AIA
5453 NW 106TH DR
CORAL SPRINGS, FL 33076
Seal:
Cr: p\Bi Eq 3A
�•e" Fd��9c
NO.
11 OZ 0]`96
S�ATE�./(OQ'
ol✓% OF
SSS/ONAL
B�
ADAM GINSBURG, PE
w.y
Owner:
THE WITNESS GROUP
600 ENTERPRISES DRIVE
LEWIS CENTER,OH
513.623.9430
HOME
CARMEL,INDIANA
PROTOTYPE VERSION-V2.22016
REVISION: MAY 2016
I NSOUE
DELTA
DATE WUE
DESCRIPTION
1
SO
2019.03.04
ISSUED FOR
PERMIT
CURRENT ISSUE
ISSUED FOR PERMIT
CURRENT ISSUE DATE
2019.03.04
DRAWN BY
Ti
CHECKED BY
AJG
PROJECT NO,
64-134-1705
SHEET NAME
INDEX AND
STRUCTURAL
NOTES
DRAWINGS NO.
S-101