HomeMy WebLinkAboutCLAY CORNER 43 - CC043 (AS DESIGNED)IECC 2009 Performance Compliance Property 1525 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON (A) Community: CLAY CORNER 43 CC043 (AS DESIGNED) CLAY CORNER 43 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,731 $271 $386 $2,388 $907 $0 $3,295 Requirements C-M, Energy Solutions As Designed $1,691 $235 $386 $2,311 $907 $0 $3,218 C4405.3 Performance-based compliance passes by 32% R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 3.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 6114119 at 8:22 AM Ekotrope RATER - Version 3.1.0.2195 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. �J PTO Pi 1525 JENSEN DR CARMEL, IN 46032 Builder: LENNAR HOMES Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.32 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 255.0 CFM @ 25Pa Total Duct Leakage 408.0 CFM @ 25Pa Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 6114119 at 8:22 AM Ekotrope RATER - Version 3.1.0.2195 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 1525 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (A) Community: CLAY CORNER 43 Builder LENNAR HOMES CC043 (AS DESIGNED) CLAY CORNER 43 General Building Information Conditioned Area (sq ft) 5,121 Conditioned Volume (cubic ft) 46,922 Insulated Shell Area (sq ft) 9,961 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT (2,093 s.f.) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 192, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 20, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB 2X4 (2,312 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I [ Name: CONDIAMB 2X6 (440 s.f.) R-3 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 1525 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (A) Community: CLAY CORNER 43 Builder LENNAR HOMES CC043 (AS DESIGNED) CLAY CORNER 43 Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (463 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (241 s.f.) R: 13.575 Name: CONDIGAR (20 s.f.) R: 10.876 Name: CONDIATTIC (82 s.f.) R: 13.575 Roof El Name: SECOND (1,853 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I El Name: SLOPED (369 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected C-M, Energy Solutions 2 Energy Code Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 1525 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (A) Community: CLAY CORNER 43 Builder LENNAR HOMES CC043 (AS DESIGNED) CLAY CORNER 43 E] Name: FRONT (145 s.f.), U:0.310, SHGC: 0.29, Orientation: SOUTH E] Name: FRONT GD (24 s.f.), U:0.290, SHGC: 0.33, Orientation: SOUTH El Name: BACK 2X6 (90 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH El Name: LEFT SIDE (48 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST El Name: LEFT SIDE 2X6 (45 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST El Name: LEFT SIDE GD (18 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST 11 Name: RIGHT SIDE (93 s.f.), U:0.310, SHGC: 0.32, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 3,910 CFM50 (5.00 ACH50) or less at final blower -door test. 3 Energy Code Inspection Checklist Property 1525 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON (A) Community: CLAY CORNER 43 CC043 (AS DESIGNED) CLAY CORNER 43 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Infiltration Requirements for IECC in Climate Zone 5 Inspection Status Results are projected 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 255.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 408.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 1525 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (A) 1 Community: CLAY CORNER 43 Builder Exposed Exterior LENNAR HOMES CC043 [AS DESIGNED] 1 CLAY CORNER 43 20 GenerAuilding Information Conditioned Space Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;121 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 46;922 Total Units in Building 1 Residence Type Single family detached Floor Number value Model PENNINGTON (A) Community CLAY CORNER 43 Climate Zone 5A Foundation Wall C-M, Energy Solutions Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4ft 1 8 192 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4ft 1 8 20 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R -value Cavity R -value Effective Insulation R - Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped_ Oft D 4 No N?A NIA 11.00 Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Masonry Area Area Location Enclosing BSMT Uninsulated 212 Below Grade 0 0 2,093.0 sq. ft. Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completely Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No ID. DD 1 Building Summary Property Organization 1525 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [A] Exposed Exterior Community: CLAY CORNER 43 Builder 82.0 s9. ft. LENNAR HOMES CC043 [AS DESIGNED] G1 R-13, OSB CLAY CORNER 43 Exposed Exterior ■ Framed Floor Framed Floor Library List Rim Joist Inspection Status Results are projected C-M, Energy Solutions Name Library Type Surface Area Location CONDIAMB G1 R-13, R-3.0 24 1. 0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13, R-3.0 82.0 s9. ft. Attic CONDIGAR G1 R-13, OSB 20.0 sq. ft. Exposed Exterior Rim Joist Library Lis Medium 440.0 sq. ft. Exposed Exterior Name Effective Insulation R -value Medium 463.0 sq. ft. G1 R-13, OSB 10.876 G1 R-13 Gar Walls Medium G1 R-13, R-3.0 13.575 2 Name Library Type Surface Calor Surface Area Location CONDIAMB 2X4 G1 R-13 BATT, R-3.0 Medium 2,312.0 sq. ft. Exposed Exterior CONDIAMB 2X6 G1 R-19, R-3.0 2X6 Medium 440.0 sq. ft. Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 463.0 sq. ft. Attic CONDIGAR G1 R-13 Gar Walls Medium 180.0 sq. ft. Llnoonddioned, attached garage 2 Building Summary Property 1525 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [A] Community: CLAY CORNER 43 CC043 [AS DESIGNED] CLAY CORNER 43 Wall Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 G1 R-19, R-3.0 2X6 20217 Glazing Inspection Status Results are projected C-M, Energy Solutions Name Library Type Wall Assignment Foundation Wall Overhang Depth Assignment Overhang Ft To Top Overhang Ft To Bottom Orientation Surface Area BACK 2X6 111-.31, SHGG.32 CONDIAMB 2X6 0 0 0 North 90.0 sq. ft FRONT 111-.31, SHGG29 CONDIAMB 2X4 0 0 0 South 145.0 sq. R. FRONT GD U-29, SHGG.33 CONDIAMB 2X4 0 0 0 South 24.0 sq. fL LEFT SIDE 111-.31, SHGG.32 CONDIAMB 2X4 0 0 0 West 48.0 sq. fL LEFT SIDE 2X6 111-.31, SHGG.32 CONDIAMB 2X4 0 0 0 West 45.0 sq. ft LEFT SIDE GD U-29, SHGG.33 CONDIAMB 2X4 0 0 0 West 18.0 sq. ft RIGHT SIDE 111-.31, SHGG.32 CONDIAMB 2714 0 0 0 East 93.0 sq. ft Glazing Library List Name Shg c U -factor U-.29, SHGC-.33 0.33 0290 U-.31, SHGC-29 0.29 0.310 U-.31, SHGC-.32 0.32 0.310 Skylight None Present 9 Building Summary Property 1525 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [A] Community: CLAY CORNER 43 CC043 [AS DESIGNED] CLAY CORNER 43 Skylight Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Opaque Door Name Library Type Wall Assignmen, FRONT Steel Door CONDIAMB 2704 GARAGE Steel Door CONDIGAR Assign ment Opaque Door Library List JL Name Effective U -factor Steel Door 0.182 C-M Energy Solutions Inspection Status Results are projected r Surface Area Location Ab sorpta n ce 0.9 0.75 Medium 20.0 sq_ tt Exposed Exterior 0.9 0.75 Medium 18.0 sq_ ft Exposed Exterior Roof Insulation M= Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location Vt.] Tiles SECOND R-38 Blown, GR1 7,853 No Medium 1,853.0 sq. fL Attic SLOPED R-30 Vaulted, GR1 369 No Medium 369.0 sq. R Attic Roof Insulation Library List _ Name Has Radiant Barrier R-30 Vaulted. Gri l No R-38 Blown. GR1 No Effective R value 27.186 38268 M Building Summary Property Organization C-MEnergy Solutions Inspection Status 1525 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [A] Community: CLAY CORNER 43 Builder LENNAR HOMES CC043 [AS DESIGNED] CLAY CORNER 43 Whole House Infiltration Infiltration Measurement Type Shelter Class 5 ACH at 50 Pa Blower -door tested 4 Mechanical Ventilation Lighting % Interior Fitiorescent % Interior LED Lighting % Exteriar Fluorescent °% Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting ❑ 100 0 70❑ ❑ 100 Onsite Generation None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List Building Summary Property Organization Inspection Status 1525 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons PSG (Single Speed) Model: PENNINGTON (A) 95.5 AFUE Heating Capacity [kBtulh] Community: CLAY CORNER 43 Builder No EAE [kWh] LENNAR HOMES Equipment Type: CA13NA042 CC043 [AS DESIGNED] Fuel Type Electric CLAY CORNER 43 Forced Air Motor Type Conditioning Equipment Cooling Efficiency 13 SEER Name Library Type Heating Percent Load Co( Air conditioner Equipment Type: RE350* CA13NA042 0% I Fuel -fired air 9155A4206OS17 100% distribution IWater Heating RE350" 0% 1 Equipment Type: 915SA4206OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5 AFUE Heating Capacity [kBtulh] 58 Use default EAE No EAE [kWh] 636 Equipment Type: CA13NA042 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 46 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 C-M, Energy Solutions g Percent Load Hot Water 100% 0% 0% 0% 0% 100% Building Summary Property C-MEnergy Solutions Organization Inspection Status 1525 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [A] Community: CLAY CORNER 43 Builder LENNAR HOMES CC043 [AS DESIGNED] CLAY CORNER 43 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 5121 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 20 Supply Duct Area [sq. ft.] 1382.67 Return Duct Area [sq. ft_] 1024.2 Duct Leakage to Outdoors (CFM25) 255 Total Leakage 408 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rCeiling Fan W Has Ceiling Fan No Cfm Per Watt 101 7 Building Summary Property 1525 JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [A] Community: CLAY CORNER 43 CC043 [AS DESIGNED] CLAY CORNER 43 Water Distribution MM Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 75 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � C-M, Energy Solutions ,�