Loading...
HomeMy WebLinkAbout205JGB - Energy CertHOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 12232 Hobby Horse Drive, Carmel, IN by Wedgewood Building Co., LLC. exceeds the minimum requirements for the 2009 International Energy Conservation Code The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.7 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Building Features Ceiling Flat R-38.0 Duct NA Sealed Attic: NA Duct Leakage to Outside: 260.00 CFM @ 25 Pascals Vaulted Ceiling NA Total Duct Leakage: 548.00 CFM @ 25 Pascals Above Grade Walls R-18.0 Infiltration: Htg: 6.00 Clg: 6.00 ACH50 Foundation Walls R-13.0 Window U-Value: 0.300, SHGC: 0.290 Exposed Floor NA Heating Fuel-fired air distribution, Natural gas, 95.0 AFUE. Slab R-0.0 Edge, R-0.0 Under Cooling Air conditioner, Electric, 14.0 SEER. Water Heating Conventional, Natural gas, 0.70 EF, 50.0 Gal. Name Ian Carstairs Signature Organization IC Energy Services Date 9 July 2019