HomeMy WebLinkAbout205JGB - Sewer PermitSuite A
incamenuer
SANITARY SEWER PERMIT
999913346
Permit Type
Final
Subdivision
Jacksons Grant
Project WO
2017-1339
Section Number
4
Project Name
Jacksons Grant Section 4
Lot Number
205
Project Developer
Jackson's Grant Real Estate Company
Address Number
12232
Lift Station
26 Jacksons Grant
Address 2
Treatment Plant
MIX
Street
Hobby Horse Drive
Parcel Acreage
0.23
City
Carmel
EDU in Gallons
310
Zip Code
46032
County
Hamilton
Local Sewer Charge - District Contribution 0.00
Builder
Wedgewood Building Company
Plan Review and Inspection 0.00
Application Fee
150.00
Phone Number
317-669-6315
EDU Fee
19D8.00
Owner
Interceptor Fee
0.00
Phone Number
Other Fees
0.00
-
Fees Due
2058.00
Occupant
Invoice Number
Phone Number
PLEASE NOTE: Installation of building sewer shall be per the specifications of the TnCo Regional Sewer Utility (see
reverse) and any conditions noted below. All installations shall be inspected by TriCo personnel during "open trench"
phase and before backfilling with stone to twelve inches above the pipe. NO footing or foundation drains, or other
sources of ground or stormwater, shall be permitted to enter TriCo's sanitary sewer system. TriCo will assume no
liability for drains which are below the grade level of the nearest downstream manhole nor for laterals which are
extended beneath driveways or sidewalks. The permit holder (property owner, developer or builder) will be
responsible for damages to TriCo's sewer system. This includes damages to manholes, castings, manhole lids and
the like; caused by construction activity on the building site which is the subject of this permit.
Inspections by TriCo are MANDATORY and shall be arranged by contacting TriCo's office at 844-9200 24 hours in
advance. All new construction will be placed on billing two months after connection has been made or when water is
connected, whichever comes first.
The building has: Main ID: JG856JG867
Grease Trap Slab Foundation
Grease Interceptor Crawl Space Manhole IDs USMH JG -856 l JG -857 DSMH
Grit Interceptor Basement YES Lid Elevation 861.76y 861.88
Grinder Station First Floor Elevation
864.10 864.10
Water Service City of Carmel Basement Elevation 854.10/ 854.10
Cekula6'on is based on both Manhole Litl Ekvafions antl fhe elevation olthe First Floor 2.34 2.22 FLS
Per Ordinance 9-13-99 and the elevations provided, the substructure shall be plumbed by: Ejector Pump Only
TnCo currently requires that an IM inspection is performed and a Certificate of Compliance is issued prior to occupancy /
sale of a property. Please review attached Ill Permit.
Manholes shall remain accessible at all times. Buried manholes will be corrected by the Developer/Owner.
The proper class of cleanout must be installed every 100 feet of lateral pipe measured from sewer main to structure.
The terms of the conditional permit, if any, are listed below.
_ Plans have been submitted.
All fees have been paid.
_ No additional permits required.
_ No manhole core permit required.
The facility is not classified as a FOG facility.
By signing below, I attest that I ai
Builder / Owner Signature
Printed Name IrQit1 1—J o+, 1 P
Approved
antl ag ee
Phone Number --1 (vS- L-3 q —Q05D
Permit is val4for ONgYEAR from the date issued. Permit valid only with
SUMMARY OF LATERAL INSTALLATION REQUIREMENTS
1. Only one building may connect to the sewer main per lateral unless otherwise approved by TriCo.
2. Foundation chains, sump drains, downspouts and other stone water drains shall never be connected to the sanitary sewer.
Site dewatering systems shall never be discharged to the sanitary sewer.
3. The existing sewer line from the building to the septic tank may only be reused if it is located under a building addition, patio,
parch or paved driveway, and the line passes an air test that is observed by TnCo. Contact TnCo for more information about
air testing requirements. The property owner is responsible for testing costs.
4. TriCo shall inspect all new laterals or lateral repairs in their entirety. Final connection to the sanitary sewer must be observed
by Trico. The property owner or contractor must notify Tri prior to backfilling. Inspections must be scheduled at least 24
hours in advance. If an inspection fails and subsequent inspections are required, or if the contractor is not on s"de for the
scheduled inspection, a $100 fee will be assessed and must be paid prior to scheduling the reinspection.
5. Septic system contents or effluent shall never be discharged to the sanitary sewer. Be advised that your county health
department regulates septic systems. Upon connection to sanitary sewer, a septic tank must typically be abandoned,
pumped clean, and filled completely with earthen material, Contact your county health department for more information on
septic system and abandonment requirements, and to notify the department of any abandonment.
6. The following materials are acceptable for use in gravity sewer lateral installation or repair:
PVC pipe: SDR 35 or SDR 26, ASTM D3034, 6° diameter
PVC pipe, pressure rated: SDR 21, ASTM D2241, 6' diameter
PVC restrained joint pipe for directional drilling: Certaflo Greenline SDR 21, ASTM D2241, 6' diameter
All gasketed joints shall meet ASTM D3212
All fittings shall be SDR26 or better
Ductile iron mechanical joint things with proper hardware
SDR 26 Basketed repair sleeves or Indiana Seal shear guard
Fernco and similar flexible couplings are only acceptable in certain circumstances and shall not be used without
prior approval from ThCo
Cleanouts: 6' threaded PVC caps
Bedding: Use #8 crushed stone or fractured face aggregate
The following materials are acceptable for use in low-pressure sewer lateral installation or repair:
HDPE pipe for directional drilling: DR 11 IPS, 1.25' diameter, PE4710
Connections shall be made via electrofusion or using polypropylene or stainless steel compression fittings
Electrofusion high volume tapping tee, rated 200 psi, PE4710
1.25' IPS full port 1/4 tum fusible PE ball valve, rated 200 psi
Threaded swing check valve, 315 stainless steel, rated 200 psi
Contact TriCo for acceptable pump station materials, equipment, pumps and other requirements
7. For gravity and low-pressure systems, the line leaving the building shall not exceed Tin length before a cleanout must be
added and the line is transitioned to 6' diameter SDR 35 PVC pipe. Glued joints are not allowed after 3'. No additional glued
fittings are allowed between the building and the transition/cleanout For all gravity lines, cleanouts shall not be spaced more
than 100' apart between the building and the sewer main. See TriCo's standard drawings for more information on cleanout
installation.
S. Bedding material shall be placed from at least 6 inches below to 12 inches above the pipe surface. The trench shall be a
minimum of 18' wide with at least 6' of clearance on both sides of the pipe. Material shall be placed over the pipe and tracer
wire after inspection. Soft, unstable or unsuitable material found below and near the lateral, including any fill or foundation
backfill material, must be removed and replaced with #8 stone. The contractor is solely responsible for establishing stable
pipe bedding conditions.
9. #10 -AWG solid copper tracer wire shall be laid on top of and run the entire length of the lateral. All splicing of tracer wire
shall use 31A splice kit model DBR/Y-6, King Innovation Dryconn Direct Bury Lug Aqua catalog #90220, or ThCo approved
10. Laterals shall be installed at least 20' from water wells unless PVC pressure grade pipe is used. Any proposed installation
requiring pressure pipe shall be reviewed by THGo prior to installation. Where a transition is made between SDR 35 pipe and
pressure grade SDR 21 pipe, a ductile iron gasketed mechanical couplings must be used.
11. Laterals less than 5' deep shall be at least 24' from the property line. Laterals more than 5' deep shall be at least 36' from
the property line. Where the lateral runs in close proximity to the property line the property comers must be accurately
staked by a professional land surveyor prior to inspection.
12. Laterals running parallel to a building or structure shall beat least 36' from the face of a crawl space or slab on grade
foundation and 60' from the face of a basement foundation wall. Spacing requirements also apply with respect to the
ancillary structure's foundation depth. Ancillary structures (e.g. window wells) and other utilities shall not be placed over or
near the lateral. TnCo may adjust requirements where future access to the lateral may be obstructed by other utilities. The
contractor should call to discuss further if he/she believes this could be an issue.
13. All infrastructure connected to Tril sewer system may be tested, inspected, or televised at TriCo's discretion, and must
remain accessible and properly maintained.
14. Call 811 or 1-800-382-5544 before you dig. For more information go to www. indiana811.org.
TriCo Regional Sewer Utility
10701 North College Avenue Suite A
Indianapolis, Indiana 46280
Phone (317)-844-9200 Fax (317)-844-9203
Revised 031192019
n WEDGEWOOO BUILDING COMPANY LLC 12089
32 FIRST STREET COM ft*
CARMEL, INDIANA 46032
(317) 8698312 7157IPQ
07116/2019
s
PAY i
TOTRE TriCo Regional Sewer Utility 2,058.00 7
ORDER OF
Two Thousand Fifty-Eight and 00/100•••••«••••••••••••••••••••••••••••••••••••••..•••••••»••»••••••.•••.••»•••••••»•• DOLLARS
TnCo Regional Sewer Utility
PO Box 40638 8
Indianapolis IN 46240
MEMO w7nowzeo n� pE �!
Sewer Permit
11.01208900 1:0749037191; 101626765811•
TriCo Regional Sewer Utility
to/u1 N, college Avenue Suite A
Indianapolis, Indiana 46260
phone 317-844-9200 fax 317-844-9203 www.Mw.eco
Residential
I & 1 permit Ordinance 12-08-08
Lateral Location
Water Type
Owner/Occupant Information
Address Number
12232
Owner
Address 2
Cleanout
First Name
Street
Hobby Horse Drive
Last Name
City
Carmel
Phone Number
State
IN
Mobile Number
Zip Code
46032
Fax Number
Subdivision
Jacksons Grant
Email Address
Section Number
4
Lot Number
205
Permit Information
Owner Address if iDiHerent
Address Number
Address 2
Street
City
State
Zip Code
Builder Information
Builder Wedgewood _Building Company
Phone Number 317-6696315
Facility Features and Addition Information
Slab Foundation
Square Footage
Crawl Space
Water Type
City of Carmel
Basement
YES
Basement Status
Ejector Pump Only
Cleanout
YES
Main ID
JG856-JGB57
Ejector Pump
YES
Lift Station
26 Jacksons Grant
Sump Pump
YES
Grinder Station
Program Specifications
• This program requires prior to the sale/occupance of a property that the property owneribuilder notify TriCo and
schedule an inspection. The inspection will verify that:
• Downspouts are not connected to the sanitary sewer
• The sump pump is not connected to the sanitary sewer
• Cleanout caps are in place and watertight
• No yard drains are connected to the sanitary sewer
• There are no sinkholes or other indications that the sewer lateral is leaking
• 5 Ton or greater HVAC units do not dishcarge condenstion to the sanitary sewer.
• If deficiencies are found, the property owner will be notified and must make corrections immediately. The property
owner will need to schedule a follow up inspection. If a certificate of compliance is not issued within 30 days of the
change in ownership, a sewer surcharge of $20 per month will be assessed and added to the sewer bill.
Owner I Occupant Signature:
�j LIP -k Lk R Date:
Approved By: Qui J1• J 14 d Date:
JACKSON'LUAMS S GRANT PLOT PLAN
IN W 2018- CREEK n
INST.g2018-009549 I1 N
LOT #205 — SECTION 4 f PREPARED FOR
CITY OF CARMEL, INDIANA WEDGEWOOD BUILDING COMPANY
12232 HOBBY HORSE DRIVE
LOT SIZE:
9,937 SO.FT.
GONG. DRIVEWAY:
992± SOFT.
PUBLIC WALK:
257± SOFT.
PRIVATE WALK:
O± SOFT.
SEEDING:
2.697* SOFT.
SOD:
315± SO.YD.
A
{' a
/Q. No. °t
* �LS20300026i
STATE OF
i ( , Ao `T
c. n
U.E.
SUMP DRAJN�
slue
tAY POSCX ifsY
LINE
♦ 17eY vW
LOT #205
9,937 S.F. N
L PROPOSED e N
9 RESIDENCE #
F.F. - RB4.,' MAN
ew.T-BB 1' RFMAlty ES
'9,aoo
AT' A&
naY n e.
PROP. 8
DRIAE
SSE
' SIDEWALK
b.b
nl
�f
HOBBY HORSE DRI
w H 1
M
M
NOTE-
- MIME ENTRY TO CONFORM MIN GTY OF CARMEL STANDARDS
- THE LOCATIONS, DIMENSION$ AND MOTH ALONG THE PROPOSED PUBLIC SIDEWALK WERE SCALED
OR TAKEN FROM ENGINEERING CONSTRUCTON PLANS PREPARED BY OTHERS OR AS PROWDED.
- VERIFY SANITARY LATERAL LOCAnON PRIOR TO CONSTRI CION
- IT SHALL SE THE REEPO SIBIIJW OF NE BUILDEN/CCNIMCTOR TO VERIFY THE BUILDING
000.0 — PROPOSED GRADE DIMENSIONS, BUILDING LOCAIONS. THE LGGAnON OF OTHER PQinrENT FEATURES AND
FIEVAA NIS PRIOR TO THE START OF CONSTRUCGON. TIff INTENDED USE OF THIS PLOT P'LW IS
000.0 — EXISTING GRADE FOR SECURING WILDING PERMITS ONLY AND SHALL NOT BE USED FOR ANY OTHER PIJ P
,lN1, ruNRInV11GMrYWf,RT,Nf. ... Y'T I D. o7/Ts/,vI SFAtr- " a ]o'
JWJ7L & LAND SURVEYING SERVTCBS
i /�fl116500h.Rm4stilwlDooafl9
JOB# 12-473
REV.:
ZONED: BRIOGEMONT
F.F.E. HSE: 864.1'
NoRrg P1,ovc(n7)aal475e
ZONING: 5/10' SIDE
F.F.E. GAR: 862.8'
v w,,,ea,rn<ro�R�r�o„ Fee: (317)441' 6z
H.nvl:'hOvfylyumonhiv6v.com
20' REAR
F.F.E. BSM'T: 854.1'