Loading...
HomeMy WebLinkAboutTLR-026 ENERGYIECC 2009 Performance Compliance Property Organization 14434 TALLYN WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: STANTON(WC) Michael Hill Community: TALLYNS RIDGE 26 Builder TLR026 (AS DESIGNED) FISCHER HOMES TALLYNS RIDGE 26 Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,903 $297 $414 $2,614 $1,388 $0 $4,002 Requirements C4405.3 Performance-based compliance passes by 3.0% R402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C-M, Energy Solutions As Designed $1,849 $273 $414 $2,536 $1,388 $0 $3,924 Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 711119 at 9:45 AM Ekotrope RATER - Version 3.1.0.2206 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14434 TALLYN WAY I�JPTO Pl CARMEL, IN 46074 Builder: FISCHER HOMES Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-30 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.29 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 348.0 CFM @ 25Pa Total Duct Leakage 464.0 CFM @ 25Pa Heating Furnace • Natural Gas • 96.1 AFUE Cooling Air Conditioner • Electric • 14 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 711119 at 9:45 AM Ekotrope RATER - Version 3.1.0.2206 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14434 TALLYN WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: STANTON(WC) Michael Hill Community: TALLYNS RIDGE 26 Builder TLR026 (AS DESIGNED) FISCHER HOMES TALLYNS RIDGE 26 General Building Information Conditioned Area (sq ft) 5,813 Conditioned Volume (cubic ft) 53,057 Insulated Shell Area (sq ft) 10,595 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT(2,016 s.f., 224 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor El Name: OVER GARAGE (154 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I El Name: OVER AMB (36 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 165, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 59, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 10.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB (2,570 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 14434 TALLYN WAY TSI Energy Solutions CARMEL, IN 46074 317-846-4655 Model: STANTON(WC) Michael Hill Community: TALLYNS RIDGE 26 Builder TLR026 (AS DESIGNED) FISCHER HOMES TALLYNS RIDGE 26 El Name: CONDIAMB 2X6 (315 s.f.) R-0.41 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (531 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIATTIC (328 s.f.) R-0.205 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist Name: CONDIAMB (259 s.f.) R: 11.691 Name: CONDIGAR (59 s.f.) R: 11.691 Name: CONDIATTIC (105 s.f.) R: 11.691 Roof El Name: SECOND (2,206 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist Property 14434 TALLYN WAY CARMEL, IN 46074 Model: STANTON(WC) Community: TALLYNS RIDGE 26 TLR026 (AS DESIGNED) TALLYNS RIDGE 26 Glazing Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Inspection Status Results are projected El Name: FRONT (155 s.f.), U:0.310, SHGC: 0.26, Orientation: EAST Name: BACK (291 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST E] Name: BACK 2X6 (53 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST El Name: BACKSLIDER (40 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST E] Name: RIGHT SIDE (114 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH El Name: RIGHT SLIDER (40 s.f.), U:0.290, SHGC: 0.33, Orientation: NORTH El Name: RIGHT BSMT (5 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH El Name: LEFT SIDE (92 s.f.), U:0.310, SHGC: 0.29, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment M Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 96.1 AFUE E] Air conditioner (2) • Electric • 100% Cooling Load @ 14 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control C-M, Energy Solutions 3 Energy Code Inspection Checklist Property Organization Inspection Status 14434 TALLYN WAY TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: STANTON(WC) Michael Hill Community: TALLYNS RIDGE 26 Builder TLR026 (AS DESIGNED) FISCHER HOMES TALLYNS RIDGE 26 ElTest Status: Blower -door tested House is air -sealed as to achieve 4,421 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 348.0 CFM @ 25 Pa Total Duct Leakage is specified in Ekotrope at 464.0 CFM @ 25Pa Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM251100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25/ 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage t= 4 CFM25/ 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25/ 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes Building Summary Property Organization Inspection Status 14434 TALLYN WAY TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: STANTON(WC) Michael Hill Community: TALLYNS RIDGE 26 Enclosing CONDIAMB R-10 Draped, 4Pt Builder TLR026 [AS DESIGNED] FISCHER HOMES TALLYNS RIDGE 26 CONDIGAR R-10 Draped, 4Pt Genera?Building Information 8 59 Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;813 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 53;457 Total Units in Building 1 Residence Type Single family detached Floor Number Top Model STANTON(WC) Community TALLYNS RIDGE 26 Climate Zone 5A C-M, Energy Solutions Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-10 Draped, 4Pt 1 8 165 Exposed Exterior Conditioned Space CONDIGAR R-10 Draped, 4Pt 1 8 59 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R -value Cavity R -value Effective Insulation R - Continuous Insulation Continuous Insulation value Top Bottom R-10 Draped_ Oft D 4 No N?A NIA 1000 Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Masonry Area Area Location Enclosing BSMT Uninsulated 224 Below Grade 0 0 2:016.0 R2 Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame/ Other No 0 0 0 No ID. DD 1 Building Summary Library Type Surface Calor Surface Area Property Organization Inspection Status C-MEnergy Solutions 14434 TALLYN WAY TSI Energy Solutions Results are projected G1 R-19 BATT, T -PLY CARMEL, IN 46074 317-846-4655 Exposed Exterior CONDIATTIC Model: STANTON[WC] Michael Hill Surface Area Location Community: TALLYNS RIDGE 26 G1 R-15, OSB Builder Exposed Exterior CONDIATTIC TLR026 [AS DESIGNED] FISCHER HOMES Attic CONDIGAR TALLYNS RIDGE 26 G1 R-15, OSB Framed Floor Unconditioned, attached garage Name Library Type Carpet R Floor Grade Surface Area Location OVER AMB R-30, GR1 Name Effective Insulation R -value 1.23 Above Grade 36.0 T Exposed Exterior OVER GARAGE R-30, GR1 154.0 T Unconditioned, attached 1.23 Above Grade garage Framed Floor Library List Library Type Surface Calor Surface Area Name Effective R -value G1 R-15 BATT, T- PLY Medium -• » 27.493 CONDIAMB 2X6 G1 R-19 BATT, T -PLY Rim Joist i 315.0 HY Exposed Exterior CONDIATTIC Name Library Type Surface Area Location CONDIAMB G1 R-15, OSB 259.0 fF Exposed Exterior CONDIATTIC G1 R-15, OSB 105.0 fl, Attic CONDIGAR G1 R-15, OSB 59.0 fF Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R -value G1 R-15, OSB 11.691 ii Name Library Type Surface Calor Surface Area Location CONDIAMB G1 R-15 BATT, T- PLY Medium 2.570.0 P[' Exposed Exterior CONDIAMB 2X6 G1 R-19 BATT, T -PLY Medium 315.0 HY Exposed Exterior CONDIATTIC G1 R-15 BATT, T -PLY Medium 328.0 ft' Attic 2 Building Summary Property 14434 TALLYN WAY CARMEL, IN 46074 Model: STANTON[WC] Community: TALLYNS RIDGE 26 TLR026 [AS DESIGNED] TALLYNS RIDGE 26 Name Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Library Type Inspection Status Results are projected Surface Calor Surface Area C-MEnergy Solutions Location CONDIGAR G1 R-15 Gar Walls Medium 531.0 fts Unconditioned, attached garage Wall Library List Name Effective R -value G1 R-15 BATT, T -PLY 12.842 G1 R-15 Gar Walls 11.972 G1 R-19 BATT, T -PLY 17278 Glazing Name Library Type Wall Assignment Foundation Wall Assignment Overhang Depth Overhang Ft Top To Overhang Ft To Bottom Orientation Surface Area BACK U-.31, SHGC-29 CONDIAMB 0 0 0 West 291.0 R2 BACK 2X6 U-.31, SHGC-.29 CONDIAMB 2X6 0 0 0 West 53.0 fF BACK SLIDER U-29, SHGG.33 CONDIAMB 0 0 ❑ West 40.0 f' FRONT U-.31, SHGC-26 CONDIAMB 0 0 ❑ East 155.0 fts LEFT SIDE U-.31, SHGG29 CONDIAMB 0 0 0 South 92.0 ft RIGHT BSMT U-.31, SHGG29 CONDIAMB 0 0 ❑ North 5.0 R2 RIGHT SIDE U-.31, SHGG29 CONDIAMB 0 0 0 North 114.0 ft' RIGHT SLIDER U-29, SHGG.33 CONDIAMB 0 0 0 North 40.0 ft' Glazing Library List Name Shgc U -factor U-29, SHGC-.33 0.33 0290 U-.31, SHGC-26 026 0.310 U-.31, SHGC-29 029 0.310 Building Summary Property 14434 TALLYN WAY CARMEL, IN 46074 Model: STANTON[WC] Community: TALLYNS RIDGE 26 TLR026 [AS DESIGNED] TALLYNS RIDGE 26 Skyligh Skylight Library List Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder FISCHER HOMES Inspection Status Results are projected C-M, Energy Solutions Opaque Door �.A FM 0 Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 0.9 0.75 Medium 20.0 T Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 ft' Exposed Exterior GARAGE Steel Door CONDIGAR 0.9 0.75 Medium 18.0 fr Exposed Exterior Opaque Door Library List Name Effective U factor Steel Door 0.182 Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location �.f.] Tiles SECOND R-38 Blown, GRi 2,206 No Medium 2,206.0 f[s Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value R-38 Blown, GRi No 38268 4 Building Summary Property Organization C-MEnergy Solutions Inspection Status 14434 TALLYN WAY TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4656 Model: STANTON[WC] Michael Hill Community: TALLYNS RIDGE 26 Builder TLR026 [AS DESIGNED] FISCHER HOMES TALLYNS RIDGE 26 Whole House Infiltration Infiltration Measurement Type Shelter Class 5 ACH at 50 Pa Blower -door tested 4 Mechanical Ventilation Lighting % Interior Fitiorescent % Interior LED Lighting % Exteriar Fluorescent °% Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting Lighting Lighting Lighting t❑ ❑ 0 ❑ ❑ ❑ Onsite Generation None Present Onsite Generation Library List None Present Solar Generation Solar Generation Library List Building Summary Property Organization Inspection Status 14434 TALLYN WAY TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4656 Hot Water Efficiency Model: STANTON(WC) Michael Hill 50 Community: TALLYNS RIDGE 26 15.4 Recovery Efficiency 0.98 Builder el Type TLR026 (AS DESIGNED) FISCHER HOMES Forced Air TALLYNS RIDGE 26 PSC (Single Speed) ating Efficiency Conditioning Equipmen ating Capacity [kBtulh] 96 Name Library Type Heating Percent Load Co( Air conditioner (2) quipment Type: GSX14048 GSX14048 0% I Fuel4red air GMSS961005CN 100% distribution (1) IWater Heating (3) ENT 50 100 0% 1 Equipment Type: ENT 50 100 Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 quipment Type: GMSS961005CN el Type Natural Gas stribution Type Forced Air otor Type [EAE PSC (Single Speed) ating Efficiency 96.1 AFUE ating Capacity [kBtulh] 96 e default EAE No [kWh] 1;077 quipment Type: GSX14048 Fuel Type Electric Distribution Type Forced Air Motor Type PSC (Single Speed) Cooling Efficiency 14 SEER Cooling Capacity [kBtulh] 45 C-M, Energy Solutions g Percent Load Hot Water 100% 0% 0% 0% 0% 100% 6 Building Summary Property C-MEnergy Solutions Organization Inspection Status 14434 TALLYN WAY TSI Energy Solutions Results are projected CARMEL, IN 46074 317-846-4655 Model: STANTON(WC) Michael Hill Community: TALLYNS RIDGE 26 Builder TLR026 [AS DESIGNED] FISCHER HOMES TALLYNS RIDGE 26 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution (1) Cooling Equipment Air conditioner (2) Sq. Feet Served 5813 # Return Grilles 4 Supply Duct R Value 30 Return Duct R Value 30 Supply Duct Area r] 1177.1 Return Duct Area [ft2] 872 Duct Leakage to Outdoors (CFM25) 348 Total Leakage 464 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 80 Percent Return Area 86 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 20 Percent Return Area 20 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rCeiling Fan W Has Ceiling Fan No Cfm Per Watt 101 7 Building Summary Property 14434 TALLYN WAY CARMEL, IN 46074 Model: STANTON[WC] Community: TALLYNS RIDGE 26 TLR026 [AS DESIGNED] TALLYNS RIDGE 26 Water DistributionMM Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder FISCHER HOMES Standard No 134 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year "M � C-M, Energy Solutions ,�