HomeMy WebLinkAboutTLR-026 ENERGYIECC 2009 Performance Compliance
Property Organization
14434 TALLYN WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Model: STANTON(WC) Michael Hill
Community: TALLYNS RIDGE 26
Builder
TLR026 (AS DESIGNED) FISCHER HOMES
TALLYNS RIDGE 26
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,903
$297
$414
$2,614
$1,388
$0
$4,002
Requirements
C4405.3
Performance-based compliance passes by 3.0%
R402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGG
402.5
Area -weighted average fenestration 11 -11 -Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
$1,849
$273
$414
$2,536
$1,388
$0
$3,924
Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 3%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 711119 at 9:45 AM
Ekotrope RATER - Version 3.1.0.2206
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
14434 TALLYN WAY
I�JPTO Pl
CARMEL, IN 46074
Builder: FISCHER HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor R-30
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U -Value: 0.31, SHGC: 0.29
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 348.0 CFM @ 25Pa
Total Duct Leakage 464.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 96.1 AFUE
Cooling Air Conditioner • Electric • 14 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date: 711119 at 9:45 AM
Ekotrope RATER - Version 3.1.0.2206
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
14434 TALLYN WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Model: STANTON(WC) Michael Hill
Community: TALLYNS RIDGE 26
Builder
TLR026 (AS DESIGNED) FISCHER HOMES
TALLYNS RIDGE 26
General Building Information
Conditioned Area (sq ft) 5,813
Conditioned Volume (cubic ft) 53,057
Insulated Shell Area (sq ft) 10,595
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT(2,016 s.f., 224 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GARAGE (154 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
El Name: OVER AMB (36 s.f.)
R-0 continuous insulation, R-30 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 165, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 59, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 10.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (2,570 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property organization
14434 TALLYN WAY TSI Energy Solutions
CARMEL, IN 46074 317-846-4655
Model: STANTON(WC) Michael Hill
Community: TALLYNS RIDGE 26
Builder
TLR026 (AS DESIGNED) FISCHER HOMES
TALLYNS RIDGE 26
El Name: CONDIAMB 2X6 (315 s.f.)
R-0.41 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (531 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIATTIC (328 s.f.)
R-0.205 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (259 s.f.)
R: 11.691
Name: CONDIGAR (59 s.f.)
R: 11.691
Name: CONDIATTIC (105 s.f.)
R: 11.691
Roof
El Name: SECOND (2,206 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property
14434 TALLYN WAY
CARMEL, IN 46074
Model: STANTON(WC)
Community: TALLYNS RIDGE 26
TLR026 (AS DESIGNED)
TALLYNS RIDGE 26
Glazing
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Inspection Status
Results are projected
El Name: FRONT (155 s.f.), U:0.310, SHGC: 0.26, Orientation: EAST
Name: BACK (291 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
E] Name: BACK 2X6 (53 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
El Name: BACKSLIDER (40 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
E] Name: RIGHT SIDE (114 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH
El Name: RIGHT SLIDER (40 s.f.), U:0.290, SHGC: 0.33, Orientation: NORTH
El Name: RIGHT BSMT (5 s.f.), U:0.310, SHGC: 0.29, Orientation: NORTH
El Name: LEFT SIDE (92 s.f.), U:0.310, SHGC: 0.29, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
M Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 96.1 AFUE
E] Air conditioner (2) • Electric • 100% Cooling Load @ 14 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
C-M,
Energy Solutions
3
Energy Code Inspection Checklist
Property Organization Inspection Status
14434 TALLYN WAY TSI Energy Solutions Results are projected
CARMEL, IN 46074 317-846-4655
Model: STANTON(WC) Michael Hill
Community: TALLYNS RIDGE 26
Builder
TLR026 (AS DESIGNED) FISCHER HOMES
TALLYNS RIDGE 26
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4,421 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 348.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 464.0 CFM @ 25Pa
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM251100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25/ 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage t= 4 CFM25/ 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25/ 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
Building Summary
Property
Organization Inspection Status
14434 TALLYN WAY
TSI Energy Solutions Results are projected
CARMEL, IN 46074
317-846-4655
Model: STANTON(WC)
Michael Hill
Community: TALLYNS RIDGE 26
Enclosing
CONDIAMB R-10 Draped, 4Pt
Builder
TLR026 [AS DESIGNED]
FISCHER HOMES
TALLYNS RIDGE 26
CONDIGAR R-10 Draped, 4Pt
Genera?Building Information
8 59
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
5;813
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu. ft.]
53;457
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Top
Model
STANTON(WC)
Community
TALLYNS RIDGE 26
Climate Zone
5A
C-M,
Energy Solutions
Foundation Wall
Name Library Type
Height Above Grade
Depth Below Grade Perimeter
Location
Enclosing
CONDIAMB R-10 Draped, 4Pt
1
8 165
Exposed Exterior
Conditioned Space
CONDIGAR R-10 Draped, 4Pt
1
8 59
Exposed Exterior
Conditioned Space
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top To
Is Fully Insulated Continuous R -value
Cavity R -value Effective Insulation R -
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-10 Draped_ Oft D
4
No N?A
NIA
1000
Slab
Name Library Type
Perimeter Floor Grade
Carpet R Exposed Surface
Masonry Area
Area Location
Enclosing
BSMT Uninsulated
224 Below Grade 0 0 2:016.0 R2 Exposed Exterior
Conditioned
Space
Slab Library Lis
Name Wall Construction
Slab Completel Underslab Perimeter Perimeter
Thermal Break
Effective R -value
Type
Insulated. Insulation
Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Wood Frame/ Other
No
0 0 0
No
ID. DD
1
Building Summary
Library Type
Surface Calor
Surface Area
Property
Organization
Inspection Status
C-MEnergy Solutions
14434 TALLYN WAY
TSI Energy Solutions
Results are projected
G1 R-19 BATT, T -PLY
CARMEL, IN 46074
317-846-4655
Exposed Exterior
CONDIATTIC
Model: STANTON[WC]
Michael Hill
Surface Area
Location
Community: TALLYNS RIDGE 26
G1 R-15, OSB
Builder
Exposed Exterior
CONDIATTIC
TLR026 [AS DESIGNED]
FISCHER HOMES
Attic
CONDIGAR
TALLYNS RIDGE 26
G1 R-15, OSB
Framed Floor
Unconditioned, attached garage
Name Library Type
Carpet R
Floor Grade
Surface Area Location
OVER AMB R-30, GR1
Name
Effective Insulation R -value
1.23
Above Grade
36.0 T Exposed Exterior
OVER GARAGE R-30, GR1
154.0 T Unconditioned, attached
1.23
Above Grade
garage
Framed Floor Library List
Library Type
Surface Calor
Surface Area
Name
Effective R -value
G1 R-15 BATT, T- PLY
Medium
-• »
27.493
CONDIAMB 2X6
G1 R-19 BATT, T -PLY
Rim Joist i
315.0 HY
Exposed Exterior
CONDIATTIC
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-15, OSB
259.0 fF
Exposed Exterior
CONDIATTIC
G1 R-15, OSB
105.0 fl,
Attic
CONDIGAR
G1 R-15, OSB
59.0 fF
Unconditioned, attached garage
Rim Joist Library List
Name
Effective Insulation R -value
G1 R-15, OSB
11.691
ii
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-15 BATT, T- PLY
Medium
2.570.0 P['
Exposed Exterior
CONDIAMB 2X6
G1 R-19 BATT, T -PLY
Medium
315.0 HY
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, T -PLY
Medium
328.0 ft'
Attic
2
Building Summary
Property
14434 TALLYN WAY
CARMEL, IN 46074
Model: STANTON[WC]
Community: TALLYNS RIDGE 26
TLR026 [AS DESIGNED]
TALLYNS RIDGE 26
Name
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Library Type
Inspection Status
Results are projected
Surface Calor
Surface Area
C-MEnergy Solutions
Location
CONDIGAR G1 R-15 Gar Walls
Medium
531.0 fts
Unconditioned, attached garage
Wall Library List
Name
Effective R -value
G1 R-15 BATT, T -PLY
12.842
G1 R-15 Gar Walls
11.972
G1 R-19 BATT, T -PLY
17278
Glazing
Name Library Type Wall
Assignment Foundation Wall
Assignment
Overhang Depth Overhang Ft
Top
To Overhang Ft To
Bottom
Orientation
Surface Area
BACK U-.31, SHGC-29
CONDIAMB
0
0 0
West
291.0 R2
BACK 2X6 U-.31, SHGC-.29 CONDIAMB 2X6
0
0 0
West
53.0 fF
BACK SLIDER U-29, SHGG.33
CONDIAMB
0
0 ❑
West
40.0 f'
FRONT U-.31, SHGC-26
CONDIAMB
0
0 ❑
East
155.0 fts
LEFT SIDE U-.31, SHGG29
CONDIAMB
0
0 0
South
92.0 ft
RIGHT BSMT U-.31, SHGG29
CONDIAMB
0
0 ❑
North
5.0 R2
RIGHT SIDE U-.31, SHGG29
CONDIAMB
0
0 0
North
114.0 ft'
RIGHT SLIDER U-29, SHGG.33
CONDIAMB
0
0 0
North
40.0 ft'
Glazing Library List
Name
Shgc
U -factor
U-29, SHGC-.33
0.33
0290
U-.31, SHGC-26
026
0.310
U-.31, SHGC-29
029
0.310
Building Summary
Property
14434 TALLYN WAY
CARMEL, IN 46074
Model: STANTON[WC]
Community: TALLYNS RIDGE 26
TLR026 [AS DESIGNED]
TALLYNS RIDGE 26
Skyligh
Skylight Library List
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
�.A
FM
0
Name
Library Type Wall Assignment Foundation Wall
Emittance
Solar
Surface Color
Surface Area
Location
Assignment
Ab sorpta nce
FRONT
Steel Door CONDIAMB
0.9
0.75
Medium
20.0 T
Exposed Exterior
GARAGE
Steel Door CONDIGAR
0.9
0.75
Medium
18.0 ft'
Exposed Exterior
GARAGE
Steel Door CONDIGAR
0.9
0.75
Medium
18.0 fr
Exposed Exterior
Opaque Door Library List
Name Effective U factor
Steel Door 0.182
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
�.f.] Tiles
SECOND R-38 Blown, GRi 2,206 No Medium 2,206.0 f[s Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
R-38 Blown, GRi No 38268
4
Building Summary
Property
Organization
C-MEnergy Solutions
Inspection Status
14434 TALLYN WAY
TSI Energy Solutions
Results are projected
CARMEL, IN 46074
317-846-4656
Model: STANTON[WC]
Michael Hill
Community: TALLYNS RIDGE 26
Builder
TLR026 [AS DESIGNED]
FISCHER HOMES
TALLYNS RIDGE 26
Whole House Infiltration
Infiltration
Measurement Type
Shelter Class
5 ACH at 50 Pa
Blower -door tested
4
Mechanical Ventilation
Lighting
% Interior Fitiorescent % Interior LED Lighting % Exteriar Fluorescent °% Exterior LED Lighting % Garage Fluorescent % Garage LED Lighting
Lighting Lighting Lighting
t❑ ❑ 0 ❑ ❑ ❑
Onsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation
Solar Generation Library List
Building Summary
Property
Organization
Inspection Status
14434 TALLYN WAY
TSI Energy Solutions
Results are projected
CARMEL, IN 46074
317-846-4656
Hot Water Efficiency
Model: STANTON(WC)
Michael Hill
50
Community: TALLYNS RIDGE 26
15.4
Recovery Efficiency
0.98
Builder
el Type
TLR026 (AS DESIGNED)
FISCHER HOMES
Forced Air
TALLYNS RIDGE 26
PSC (Single Speed)
ating Efficiency
Conditioning Equipmen
ating Capacity [kBtulh]
96
Name
Library Type
Heating Percent Load Co(
Air conditioner (2)
quipment Type: GSX14048
GSX14048
0%
I Fuel4red air GMSS961005CN 100%
distribution (1)
IWater Heating (3) ENT 50 100 0%
1
Equipment Type: ENT 50 100
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
quipment Type: GMSS961005CN
el Type
Natural Gas
stribution Type
Forced Air
otor Type
[EAE
PSC (Single Speed)
ating Efficiency
96.1 AFUE
ating Capacity [kBtulh]
96
e default EAE
No
[kWh]
1;077
quipment Type: GSX14048
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSC (Single Speed)
Cooling Efficiency
14 SEER
Cooling Capacity [kBtulh]
45
C-M,
Energy Solutions
g Percent Load Hot Water
100%
0%
0%
0%
0% 100%
6
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
14434 TALLYN WAY
TSI Energy Solutions Results are projected
CARMEL, IN 46074
317-846-4655
Model: STANTON(WC)
Michael Hill
Community: TALLYNS RIDGE 26
Builder
TLR026 [AS DESIGNED]
FISCHER HOMES
TALLYNS RIDGE 26
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution (1)
Cooling Equipment
Air conditioner (2)
Sq. Feet Served
5813
# Return Grilles
4
Supply Duct R Value
30
Return Duct R Value
30
Supply Duct Area r]
1177.1
Return Duct Area [ft2]
872
Duct Leakage to Outdoors (CFM25)
348
Total Leakage
464
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
80
Percent Return Area
86
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
20
Percent Return Area
20
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan W
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
14434 TALLYN WAY
CARMEL, IN 46074
Model: STANTON[WC]
Community: TALLYNS RIDGE 26
TLR026 [AS DESIGNED]
TALLYNS RIDGE 26
Water DistributionMM
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
317-846-4655
Michael Hill
Builder
FISCHER HOMES
Standard
No
134
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�