Loading...
HomeMy WebLinkAboutA010WILLIAM L.KAUF H OL Z ARCHITECTSCALE: 3/4" = 1'-0"812"APPROXIMATE LINE OF 3'-0" OVERDIG UNDISTURBED SOIL #4 RE-BAR @ 24" o.c. - SET BARS BELOW SLAB - EXTEND RE-BAR 2" INTO FOUNDATION WALL - PROVIDE TIGHT/FRICTION FIT OR EPOXY T/ FDN. WALL 6" 1'-4"212"6"thk. CONCRETE PATIO - w/12" x 6" FIBER EXPANSION JOINT MAT'L @ FDN. WALL T/ SUBFLOOR 2x12 FLOOR SYSTEM T/ FINISH GRADE FACE ALL EXPOSED SIDES OF PATIO - 2x12 FLOOR SYSTEM SECTION - PATIO @ FULL GRADE SCALE: 3/4" = 1'-0" - 2x10 FLOOR SYSTEM4" 812" 1'-4" 412"APPROXIMATE LINE OF 3'-0" OVERDIG UNDISTURBED SOIL #4 RE-BAR @ 24" o.c. - SET BARS BELOW SLAB - EXTEND RE-BAR 2" INTO FOUNDATION WALL - PROVIDE TIGHT/FRICTION FIT OR EPOXY 4"thk. CONCRETE PATIO - w/12" x 4" FIBER EXPANSION JOINT MAT'L @ FDN. WALL T/ SUBFLOOR T/ FDN. WALL 2x10 FLOOR SYSTEM T/ FINISH GRADE FACE ALL EXPOSED SIDES OF PATIO SECTION - PATIO @ FULL GRADE SCALE: @ GARAGE SERVICE DOOR 3/4" = 1'-0" T/ GARAGE SLAB 1"REFER TOPLANFOR DEPTHOF POUR-THRUSECTION - WEATHERLIP 1" WEATHERLIP @ SERVICE DOOR HOLD T/ GARAGE FDN. WALL DOWN FOR SLAB POUR-THRU - REFER TO PLAN FOR DEPTH 1" 01 02 03 04 05 06 07 BLOCKS ONLY AT SIDES OF OPENING - PROVIDE RECESSED NAILING SCALE: NOTE: CONCRETE DOOR HEADER DO NOT SET NAILING BLOCK INTO (2) #4 RE-BARS - w/ 2" MINIMUM COVER - w/ 2" MINIMUM COVER - EXTEND MIN 12" BEYOND OPENING (2) #4 RE-BARS 1014"or 22 14"8'-0"or 9'-0"2"3/4" = 1'-0"7'-134" 2" 2x6 @ PATIO DOOR SECTION - CONCRETE HEADER BLOCKS ONLY AT SIDES OF OPENING - PROVIDE RECESSED NAILING SCALE: NOTE: CONCRETE DOOR HEADER DO NOT SET NAILING BLOCK INTO (2) #4 RE-BARS - w/ 2" MINIMUM COVER - w/ 2" MINIMUM COVER - EXTEND MIN 12" BEYOND OPENING (2) #4 RE-BARS 1112"or 23 12"8'-0"or 9'-0"2" 3/4" = 1'-0" 7'-012" 2" 2x6 SECTION - CONCRETE HEADER @ SGD SCALE: SECTION - FROST FOOTING @ DOOR 3/4" = 1'-0" T/ SLAB 1"1" WEATHERLIP @ DOOR T/ SLAB 2'-0" DEPTH OF INSUL.312"NOTE: BASEMENT WALL INSULATION NOT SHOWN - TYPE VARIES PER PLAN - SEE NOTES ON FDN. PLAN FOR SPECIFIC INFO RIGID INSULATION - REFER TO GN SHEET FOR R-VALUE - 24" DEPTH - @ ALL AREAS WHERE GRADE COVERS 30" OR LESS OF THE FDN. WALL ABOVE THE T/ SLAB GRAVEL FILL - 4" MINIMUM 3 12"thk. CONCRETE SLAB 6-MIL VAPOR BARRIER FOUNDATION WALL THICKNESS VARIES - REFER TO PLAN FROST FOOTING - REFER TO GN FOR MIN. FROST FOOTING DEPTH FOOTING WIDTH VARIES PER PLANREFER TO GENERAL NOTES FORMINIMUM FROST FOOTING DEPTHSCALE: SECTION - FROST FOOTING T/ SLAB 2'-0" DEPTH OF INSUL.312" 3/4" = 1'-0" NOTE: BASEMENT WALL INSULATION NOT SHOWN - TYPE VARIES PER PLAN - SEE NOTES ON FDN. PLAN FOR SPECIFIC INFO RIGID INSULATION - REFER TO GN SHEET FOR R-VALUE - 24" DEPTH - @ ALL AREAS WHERE GRADE COVERS 30" OR LESS OF THE FDN. WALL ABOVE THE T/ SLAB 1" BEVELED INSULATION GRAVEL FILL - 4" MINIMUM 3 12"thk. CONCRETE SLAB 6-MIL VAPOR BARRIER FOUNDATION WALL THICKNESS VARIES - REFER TO PLAN FROST FOOTING - REFER TO GN FOR MIN. FROST FOOTING DEPTH FOOTING WIDTH VARIES PER PLANREFER TO GENERAL NOTES FORMINIMUM FROST FOOTING DEPTHFDN WALL w/ SIDING or STONE @ FRONT PORCH SCALE: 3" = 1'-0" SECTION DETAIL - SIDING STARTER STRIP TITEN ANCHOR BOLT, TYP. @ PORCH SILL SEALER, TYPICAL 6"212" 512"512" REFER TO PLANFOR FDN WALL HT.2x4 LET-IN DRIP 14 (TAPE & CAULK) BLACK POLY ( 6 MIL) - BEHIND SHEATHING - 4'-0" o.c. MAX. POLY STRUCTURAL SHEATHING - HOLD 6" OFF T/FDN. WALL 24" WIDE 6 MIL POLY FLASHING - EXTEND 2" OVER FOUNDATION WALL 2 6 21 4" 13 4" PRESSURE TREATED 2x6 SILL PLATE (@ PORCH ONLY) 08 09 FDN WALL w/ BRICK VENEER @ FRONT PORCH SCALE: 3" = 1'-0" SECTION DETAIL -TITEN ANCHOR BOLT, TYP. @ PORCH - 4'-0" o.c. MAX. STRUCTURAL SHEATHING @ 24" o.c. HORIZONTAL BRICK WEEPHOLES AIR SPACE, TYPICAL 1"- HOLD BTM OF SHEATHING 1" BELOW T/ SUBFLOOR SILL SEALER, TYPICAL - w/ WEEP CARDS 6"412" 312"512"REFER TO PLANFOR FDN WALL HT.24" WIDE 6 MIL POLY FLASHING MYLAR - LOCATED ON BACKSIDE OF STRUCTURAL SHEATHING POLY 2 4 - EXTEND 2" OVER FOUNDATION WALL 10 BRICK CURB @ FRONT PORCH FDN WALL SCALE: 1 1/2" = 1'-0" SECTION DETAIL - 8" THICK CAST-IN-PLACE CONCRETE FOUNDATION WALL - UNLESS NOTED OTHERWISE ON FOUNDATION PLAN 312"778" 512"2x6 AND 2x4 BLOCKING FOR BRICK CURB - BRICK SHOWN DASHED 2 6 SLOPE TALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 Olympic Blvd, suite 100Erlanger, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:7/1/2019 8:16 AM# TLR010260000 MONISH PASSEY14434 TALLYN WAYSTANTON57-460-STANTON WESTERN CRAFTSMAN WITH BRICK CARMEL, IN26 05/2017 -------- ----------------------------------------Masterpiece fieldspecchange@fischerhomes.com REVISED BY:---- VANDANA PASSEYARCH. SPECIALIST:SAPPHIRE TRADE SUPPORTsapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----D2.2 07/22/19 Adam Schriner