HomeMy WebLinkAboutS001REFER TO DETAIL SHEET D2.3 FOR DOVETAILS FOR SIDING TO GRADE NOTE:UPREFER TO DETAIL SHEET D2.0 FOR GARAGE SLAB REBAR REQUIREMENT NOTE: 08 D2.1 D A BC 08 D2.1 16'-7" TO ℄ DRAIN 27"x27"x12" C.I.P. CONCRETE COLUMN FOOTING - HOLD T/FT'G. DOWN 3 12" FROM T/SLAB 33"x33"x15" C.I.P. CONCRETE COLUMN FOOTING - HOLD T/FT'G. DOWN 3 12" FROM T/SLAB VERTICAL CONTROL JOINT -DTL. 01/D2.112'-278"TO ℄ TOILET DRAIN10'-10" 3'-1112" TO NOSING 512" WATER SOFTENER LOCATION 12'-1034"WET BAR ROUGH-IN GROUNDING ROD - PREF. LOCATION - KY ONLY 8" 20'-3" 8" PREF. EJECTOR LOCATION PREF. SUMP LOCATION FURNACE HOLD T/ GARAGE SLAB DOWN 1" FROM T/ FDN. & SLOPE TO O.H. DOOR 3"Ø, 11 Ga. ADJUSTABLE STEEL COLUMN 18'-1"9'-538"TO ℄ SHOWER DRAINROUGH-IN FULL BATH 9'-914" 9'-9 14"2x4 NOTCH IN WALL SLOPE 3" FROM REAR WALL TOWARD GARAGE DOOR DETAIL - 04/D2.1 14'-2"29'-712" 2'-0" 9'-8" LINE OF LANDING ABOVE 10"18'-6" 10"10"19'-5" 17'-512" TO ℄ STEEL BEAM8" x 20" C.I.P. CONCRETE FOOTINGS 8" x 20" C.I.P. CONCRETE FOOTINGS 32"x23" HOPPER 32"x23" HOPPER 19'-012" 10" 13'-512" TO ℄ STEEL COLUMN 19'-4" TO NOSING (ABOVE) 10" 11'-4" TO ℄ STEEL COLUMN W8 x 18 STEEL BEAM 3"Ø, 11 Ga. ADJUSTABLE STEEL COLUMN 42" x 42" x 18" COLUMN FOOTING - HOLD DOWN 3 12" 24" x 24" x 12" COLUMN FOOTING - HOLD DOWN 3 12"10" x 8" x 8 18" BEAM LEDGE 4'-10"10" 1'-412"10" 3"Ø SCHEDULE 40 STEEL COLUMN 14'-112" TO ℄ FLOOR DRAIN 10" C.I.P. CONCRETE FOUNDATION WALLS 10" C.I.P. CONCRETE FOUNDATION WALLS EGRESS WINDOW WELL - w/ DRAIN -HOLD T/ WINDOW 10" BELOW T/ FDN. WALL 5040 SL10"7'-612" TO ℄ STEEL BEAMCONTROL JOINT 3" Ø STEEL COLUMN 11'-4" 17'-2"℄ STEEL BEAM19'-712" 10" 3'-5" 10" #4 RE-BARS @ 11" o.c. - SIDE TO SIDE - PLACED BELOW FRONT TO BACK BARS IN SLAB #4 RE-BARS @ 18" o.c. - FRONT TO BACK - PLACED ABOVE SIDE TO SIDE BARS IN SLAB LINE OF PORCH ABOVE #4 RE-BAR - STUBBED OUT & LOOPED 8" HOLD T/ WALL DOWN 3" FROM T/ FDN. WALL 2'-312"HAUNCH2'-0"WALL5'-7"8"CONTROL JOINTBEARING WALL - DBL. 2x4 STUDS @ 19.2" o.c. - ALINE w/ JOIST's ABOVE - NO DRYWALL BELOW JOIST - ATTACH GUARDRAILS TO STUDS RADON PIPE - DETAIL 03/D2.1 WH HANDRAIL - ONE SIDE 3'-7"12'-0" BEARING WALL CONTROL JOINTW8 x 18 STEEL BEAM 9'-8" ℄ STEEL COLUMN BASEMENT UNEXCAVATED 9'-0" FOUNDATION 8"d. x 18"w. C.I.P CONCRETE FOOTING - SEE DTL. 04/D2.1 312"8"11'-2" 2'-10" 6'-3" 2'-10" 10'-1112" 35'-0"10'-4" 11'-3" 56'-7"24'-1012" 7'-2 1 2" 4'-2 12"2'-0" 14'-2" 36'-312" 7'-11"60'-412"6'-1112"26'-113 4" 33'-111 4"16'-3" 6'-43 4" 56'-7"3" 15'-6" 3"4'-512" 16'-0" 1'-4" 9'-0" 21'-8" 7'-11"60'-412"5'-912" 9'-612" WOOD RAIL 20 D3.0 WILLIAM L.KAUF H OL Z ARCHITECTFOUNDATION DIAGONALS A B A 0" A 36'-3 1/2" B 36'-3 1/2" B 0" C 67'-2 21/32" C 56'-7" D 58'-10 5/32" D 77'-1 29/32"TALLYNS RIDGEREASON FOR PLOT: PLOT DATE: Job No. Sheet No.INHOMESITE NO. OFFICE REVIEW:MASTER BY: DATE: C DATE: 3940 Olympic Blvd, suite 100Erlanger, KY 41018PH: (859) 341-4709FIELD SPEC HOTLINE: (859) 341-4709COPYRIGHT ALL RIGHTS RESERVED FISCHER HOMES, Inc.JOB INFO: DATE: PERMIT: SIGN-OFF: CONSTRUCTION:REVISION:REVISION:REVISION:REVISION:HOME TYPE:PLAN:7/1/2019 8:14 AM# TLR010260000 MONISH PASSEY14434 TALLYN WAYSTANTON57-460-STANTON WESTERN CRAFTSMAN WITH BRICK CARMEL, IN26 05/2017 -------- ----------------------------------------Masterpiece fieldspecchange@fischerhomes.com REVISED BY:---- VANDANA PASSEYARCH. SPECIALIST:SAPPHIRE TRADE SUPPORT sapphiretradepartners@fischerhomes.com Fischer Homes Indianapolis II, LLC----A2.0 SCALE = 1'-0" FOUNDATION PLAN 1/4"01 FOUNDATION PLAN NOTE: 1. FOUNDATION WALLS SHADED AS TO BE SET AT T/ FDN ELEVATION PER PLOT PLAN 2. FOUNDATION WALLS UNSHADED TO BE DROPPED AS NOTED ON FOUNDATION PLAN FLOOR PLAN NOTE: 1. ALL EXTERIOR WALLS SHALL BE FRAMED @ 16" o.c. 2. INTERIOR WALLS SHADED AS INDICATES INTERIOR LOAD BEARING WALL TO BE FRAMED @ 19.2" o.c. (UNLESS OTHERWISE NOTED ON PLAN) - ALIGN JOISTS w/ STUDS. 3. INTERIOR WALLS SHADED AS INDICATES INTERIOR WALLS TO BE FRAMED @ 16" o.c. 07/22/19 Adam Schriner