HomeMy WebLinkAboutCLAY CORNER 44 - CC044 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1529 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL(B)
Community: CLAY CORNER 44
CC044 (AS DESIGNED)
CLAY CORNER 44
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,286
$180
$333
$1,799
$776
$0
$2,576
Requirements
C-M,
Energy Solutions
As Designed
51,264
S157
S333
$1,755
5776
so
$2,531
C4405.3 Performance-based compliance passes by 2.5%
R402.4.12 Air Leakage Testing Air sealing is 6 -DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 2.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
6114119 at 8:34 AM
Ekotrope RATER - Version 3.1.0.2195
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
AUri Pi
1529 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor N/A
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.32
Building Features
Duct Supply R-30.0, Return R-20.0
Duct Leakage to Outside 210.0 CFM @ 25Pa
Total Duct Leakage 336.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 6114119 at 8:34 AM
Ekotrope RATER - Version 3.1.0.2195
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
1529 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL(B)
Community: CLAY CORNER 44 Builder
LENNAR HOMES
CC044 (AS DESIGNED)
CLAY CORNER 44
General Building Information
Conditioned Area (sq ft) 4,210
Conditioned Volume (cubic ft) 37,890
Insulated Shell Area (sq ft) 8,238
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT (2,105 s.f.)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
[ Name: UNFIN (Exterior Perimeter [ft]: 212, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB 2X4 (1,728 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
[ Name: CONDIAMB (192 s.f.)
R: 13.575
Energy Code Inspection Checklist
Property
1529 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL(B)
Community: CLAY CORNER 44
CC044 (AS DESIGNED)
CLAY CORNER 44
Name: CONDIGAR (20 s.f.)
R: 10.876
Roof
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
El Name: SECOND (2,105 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
inspection Status
Results are projected
El Name: FRONT (72 s.f.), U:0.310, SHGC: 0.29, Orientation: WEST
11 Name: BACK (54 s.f.), U:0.310, SHGC: 0.32, Orientation: EAST
11 Name: LEFT SIDE (54 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
11 Name: LEFT SIDE GD (18 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
E] Name: RIGHT SIDE (56 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property Organization Inspection Status
1529 JENSEN DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: CHARTWELL(B)
Community: CLAY CORNER 44 Builder
LENNAR HOMES
CC044 (AS DESIGNED)
CLAY CORNER 44
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 3,789 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 210.0 CFM @ 25 Pa
Total Duct Leakage is specified in Ekotrope at 336.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
1529 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL(B)
Community: CLAY CORNER 44
CC044 (AS DESIGNED)
CLAY CORNER 44
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization Inspection Status
1529 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL(B)
212 Exposed Exterior
Community: CLAY CORNER 44
Builder
LENNAR HOMES
CC044 [AS DESIGNED]
CLAY CORNER 44
Feet From Wall Top To Is Fully Insulated
General Building Information
R -value Effective
Number Of Bedrooms
3
Number Of Floors
1
Conditioned Floor Area [sq_ ft.]
4;210
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu- ft.]
37;890
Total Units in Building
1
Residence Type
Single family detached
Floor Number
11.00
Model
CHARTWELL(B)
Community
CLAY CORNER 44
Climate Zone
5A
Foundation Wall
C-M,
Energy Solutions
Name Library Type
Height Above Grade Depth Below Grade
Perimeter
Location
Enclosing
UNFIN R-11 Draped, Oft
1 8
212 Exposed Exterior
Conditioned Space
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top To Is Fully Insulated
Continuous R -value Cavity
R -value Effective
Insulation R -
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-11 Draped, Oft 0
4 No
NIA
NIA.
11.00
lab
�
Name Library Type
Perimeter Floor Grade Carpet R
Exposed SurfaceArea
Location
Enclosing
Masonry Area
33MT Uninsulated
212 Below Grade 0
0 2,105.0 sq. R.
Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction
Slab Completely Underslab
Perimeter Perimeter
Thermal Break
Effective R -value
Type
Insulated . Insulation Width [ft] Insulation
Depth [ft] Insulation R Value
IUninsulated Wood Frame /Other
No 0
0 0
No
0.00
1
1
Building Summary
Property
1529 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL[B]
Community: CLAY CORNER 44
CC044 [AS DESIGNED]
CLAY CORNER 44
Framed Floor
Framed Floor Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Rim Joist
Name Library Type Surface Area Location
CONDIAMB G1 R-13, R-3.0 192.0 sq. ft. Exposed Exterior
CONDIGAR G1 R-13, OSB 20.0 s9. ft. Unconditioned, attached garage
Rim Joist Library List
Name
G1 R-13, OSB
G1 R-13, R-3.0
Walr
Name
CONDIAMB 2X4
C O N DIGAR
10.876
13.575
Library Type Surface Color
G1 R-13 BATT, R-3-0 Medium
G1 R-13 Gar Walls Medium
Surface Area
Location
1.728.0 sq. fl. Exposed Exterior
180.0 sq. fl. Unconditioned, attached garage
Building Summary
Property
Organization
Inspection Status
C-MEnergy
Solutions
1529 JENSEN DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL[B]
Community: CLAY CORNER 44
Builder
LENNAR HOMES
CC044 [AS DESIGNED]
CLAY CORNER 44
WaliTibrary List
Name
Effective R -value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
Glazing
Name Library Type
0
Wall Assignment Foundation Wall Overhang
Assignment
Depth Overhang Ft
Top
To Overhang Ft To
Bottom
Orientation
M
Surface Area
BACK U-.31, SHGC-.32
CONDIAMB 2704
0
0 0
East
54.0 sq. ft
FRONT U-.31, SHGG-.29
CONDIAMB 2X4
0
0 0
West
72.0 sq. ft
LEFT SIDE U-.31, SHGG.32
CONDIAMB 2X4
0
0 ❑
North
54.0 sq. ft
LEFT SIDE GD U-.31, SHGG.32
CONDIAMB 2X4
0
0 ❑
North
18.0 sq. fL
RIGHT SIDE U-.31, SHGG.32
CONDIAMB 2X4
0
0 ❑
South
56.0 sq. ft
Glazing Library List
Name
Shg c
U factor
U-.31, SHGC-29
029
0.310
U-.31, SHGC-.32
0.32
0.310
Skylight
None Present
Skylight Library List
None Present
Building Summary
Property
Organization
1529 JENSEN DR
TSI Energy Solutions
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL[B]
Library Type Wall Assignmen
Community: CLAY CORNER 44
Builder
Steel Door CONDIAMB 2X4
LENNAR HOMES
CC044 [AS DESIGNED]
M
CLAY CORNER 44
Surface Area Location
Opaque Door
Name
Library Type Wall Assignmen
FRONT
Steel Door CONDIAMB 2X4
GARAGE
Steel Door CONDIGA.R
Opaque Door Library List
Name
ndatPon Wall
Assignment
0.182
Inspection Status
Results are projected
Solar
Absorptance
C-M,
Energy Solutions
PF
M
r
Surface Area Location
0.9 0.75 Medium 24.0 sq- ft Exposed Exterior
0.9 0.75 Medium 18.0 sq- ft Exposed Exterior
Roof Insulation i
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area
P.f.] Tiles
Location
SECOND R-38 Blown, GR1 2,705 No Medium 2,105-0 sq. R Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
?•8 3 :a l No 38268
Whole House Infiltratic
Infiltration
I6 ACH at 50 Pa
Mechanical Ventilation
Blower -door tested 4
M
Building Summary
Property
Organization
Inspection Status
1529 JENSEN DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL[B]
Community: CLAY CORNER 44
Builder
LENNAR HOMES
CC044 [AS DESIGNED]
CLAY CORNER 44
Lighting
% Interior Fluorescent
°% Interior LED Ughting % Exterior Fluorescent
% Exterior LED Lighting
Lighting
Lighting
100 0
100
Onsite GenerationMEN&MM �
None Present
Onsite Generation Library List
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Name Literary Type Heating Percent Load
Air co nd itione r CA13NA060 0%
Fuel4red air 9155A4206OS17 100%
distribution
Water Heatinq RE350" 0%
C-M,
Energy Solutions
Fluorescent
Lighting
C 10
Cooling Percent Load Hot Water Percent Load
100%
0%
0%
0%
0% 100%
Building Summary
Property
1529 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL(B)
Community: CLAY CORNER 44
CC044 [AS DESIGNED]
CLAY CORNER 44
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Equipment Type: 915SA4206OS17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
58
Use default EAE
No
EAE [kWh]
636
Etc uipment Type: CA13NA060
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
i
Electric
Forced Air
PSG (Single Speed)
13 SEER
58.2
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
C-M,
Energy Solutions
A
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
1529 JENSEN DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Matthew Timmons
Model: CHARTWELL[B]
Community: CLAY CORNER 44
Builder
LENNAR HOMES
CC044 [AS DESIGNED]
CLAY CORNER 44
Distribution System
Distribution Type
Forced Air
Heating Equipment
Fuel -fired air distribution
Cooling Equipment
Air conditioner
Sq. Feet Served
4210
# Return Grilles
3
Supply Duct R Value
30
Return Duct R Value
20
Supply Duct Area [sq. ft.]
1136.7
Return Duct Area [sq. ft_]
631.5
Duct Leakage to Outdoors (CFM25)
216
Total Leakage
336
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan W
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
1529 JENSEN DR
CARMEL, IN 46032
Model: CHARTWELL[B]
Community: CLAY CORNER 44
CC044 [AS DESIGNED]
CLAY CORNER 44
Water Distribution MM
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
75
No
No
30
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�