Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LENNAR 44 CLAY TRS
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by ProBuild (CarterLee Bldg Components). July 11,2019 Liu, Xuegang Pages or sheets covered by this seal: I37744393 thru I37744427 My license renewal date for the state of Indiana is July 31, 2020. B19902007 LENNAR 44 CLAY IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE01 Truss Type Common Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744393 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:38 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-8rjyGiiK4GvVomyplEOb3cMIJqhoLBOg50iMrHyzCjl Scale = 1:52.2 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 28 27 26 25 24 23 22 21 20 19 18 17 16 3x6 3x6 4x6 3x6 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 10-8- 1 3 16-0-0 16-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 3-6-08-2-03-6-07.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.58 0.26 0.26 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.01 -0.02 0.00 (loc) 15 14-15 16 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 108 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 28=-221(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except 28=-300(LC 4), 16=-296(LC 5), 27=-318(LC 5), 17=-315(LC 4) Max Grav All reactions 250 lb or less at joint(s) 22, 23, 24, 25, 26, 21, 20, 19, 18 except 28=284(LC 5), 16=280(LC 4), 27=357(LC 4), 17=354(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 24, 25, 26, 21, 20, 19, 18 except (jt=lb) 28=300, 16=296, 27=318, 17=315. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE02 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744394 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:46 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-vOCzxRoMBjvMm?aLDwXTOIhnD2TCDrcrxGen7pyzCjd Scale = 1:131.2 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2021 2223 2425 2627 282930 313233 3435 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 108 107 106105104 103102 10110099 98 9796 95 94 93 92 91 908988 87868584 83 82 8180 7978 77 7675 74 73727170 69686766 65646362 61605958 5756 6x8 6x8 5x6 5x6 5x8 3x4 4x6 3x4 6x8 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 3x4 6x8 3x4 3x4 3x4 3x4 34-2-3 27- 6 - 9 12-3-9 13-2-12 13-2-12 31-10-4 18-7-8 65-3-4 33-5-0 -0-11-4 0-11-4 13-2-12 13-2-12 21-7-10 8-4-14 31-10-4 10-2-10 37-7-10 5-9-6 54-3-5 16-7-11 65-3-4 10-11-15 66-2-8 0-11-4 0-6-143-0-1311-4-110-3-142-0-011-4-116.00 12 3.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-0-11], [10:0-1-15,0-0-0], [11:0-3-8,0-4-0], [11:0-0-0,0-2-12], [20:0-4-0,0-3-8], [33:0-4-0,0-3-8], [41:0-0-0,0-2-12], [41:0-3-8,0-4-0], [42:0-1-15 ,0-0-0], [63:0-2-15,0-1-8], [89:0-3-4,0-0-8], [89:0-0-0,0-1-12], [90:0-1-12,0-0-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.14 0.10 0.12 DEFL. Vert(LL) Vert(TL) Horz(TL) in 0.00 0.01 0.02 (loc) 55 55 54 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 508 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x6 SPF No.2 *Except* 47-55: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 13-99: 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud *Except* 33-76,32-77,31-78,30-79,29-80,27-83,26-84,25-85,24-86,23-87,22-88 ,21-90,20-91,34-75,35-74,36-73: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 20-33. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 28-81, 33-76, 32-77, 31-78, 30-79, 29-80, 27-83, 26-84, 25-85, 24-86, 23-87, 22-88, 21-90, 20-91, 19-92, 34-75, 35-74, 36-73, 37-72 REACTIONS.All bearings 65-3-4. (lb) - Max Horz 2=113(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 99, 81, 54, 78, 79, 80, 83, 84, 85, 86, 87, 88, 93, 94, 95, 96, 97, 100, 101, 102, 103, 104, 105, 106, 107, 108, 74, 73, 72, 70, 69, 68, 67, 66, 65, 64, 62, 61, 60, 59, 58, 57, 56 Max Grav All reactions 250 lb or less at joint(s) 2, 99, 81, 54, 76, 77, 78, 79, 80, 83, 84, 85, 86, 87, 88, 90, 91, 92, 93, 94, 95, 96, 97, 100, 101, 102, 103, 104, 105, 106, 107, 108, 75, 74, 73, 72, 70, 69, 68, 67, 66, 65, 64, 62, 61, 60, 59, 58, 57 except 56=290(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 9-10=-19/254, 10-12=-20/270, 12-13=-8/281, 13-14=-7/288, 14-15=-19/301, 15-16=-18/317, 16-17=-18/342, 17-18=-18/369, 18-19=-19/396, 19-20=-18/406, 20-21=-1/383, 21-22=-0/383, 22-23=-0/383, 23-24=-0/383, 24-25=-0/383, 25-26=-0/383, 26-27=-0/383, 27-28=-0/383, 28-29=-0/384, 29-30=-0/384, 30-31=-0/384, 31-32=-0/384, 32-33=-1/384, 33-34=-19/406, 34-35=-19/397, 35-36=-19/370, 36-37=-16/342, 37-38=-19/318, 38-39=-18/292, 39-40=-18/267 NOTES-(15-16) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 5) Provide adequate drainage to prevent water ponding. 6) All plates are 3x6 MT20 unless otherwise indicated.Continued on page 2 July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE02 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744394 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:47 2019 Page 2 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-NamM9mp_y12DN98Xnd2iwVEyySoRyIs_AwNLfFyzCjc NOTES-(15-16) 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 99, 81, 54, 78, 79, 80, 83, 84, 85, 86, 87, 88, 93, 94, 95, 96, 97, 100, 101, 102, 103, 104, 105, 106, 107, 108, 74, 73, 72, 70, 69, 68, 67, 66, 65, 64, 62, 61, 60, 59, 58, 57, 56. 12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 83, 84, 85, 86, 87, 88, 90, 91, 92, 93, 94, 95, 96, 97. 13) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 15) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 16) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE04 Truss Type Monopitch Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744395 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:47 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-NamM9mp_y12DN98Xnd2iwVEwtSntyJo_AwNLfFyzCjc Scale = 1:29.4 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 12 11 10 9 8 7 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 6-7-15 5-11-8 5-11-8 1-10-84-10-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.27 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 30 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 5-11-8. (lb) - Max Horz 12=137(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 12, 7, 8, 9, 10 except 11=-314(LC 5) Max Grav All reactions 250 lb or less at joint(s) 7, 8, 9, 10, 11 except 12=351(LC 5) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Gable requires continuous bottom chord bearing. 4) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 7, 8, 9, 10 except (jt=lb) 11=314. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE05 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744396 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:51 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-FL0s?8sU0GYfsmSJ0T7e5LPZF38eu3Ra4YLYp0yzCjY Scale = 1:84.5 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 3x4 3x6 3x4 3x4 3x6 3x6 5x6 5x6 5x6 23-6-3 27- 7 - 1 0 23-3-0 23-3-0 44-8-0 21-5-0 45-9-0 1-1-0 13-0-6 13-0-6 23-3-0 10-2-10 29-0-6 5-9-6 44-8-0 15-7-10 45-9-0 1-1-0 2-10-811-4-112-0-01-0-62-0-011-4-116.00 12 Plate Offsets (X,Y)-- [11:0-3-0,0-2-0], [24:0-3-0,0-2-0], [32:0-3-0,0-3-0], [70:0-2-10,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.50 0.21 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.15 (loc) - - 39 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 399 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 19-60: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 *Except* 9-72,8-73,7-74,6-75,5-76,4-77,3-78,2-79,29-49,30-48,31-47,32-46 ,33-45,34-44,35-43,37-40: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 11-24. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 45-46,44-45,43-44,42-43,40-41,39-40. WEBS 1 Row at midpt 19-60, 24-55, 23-56, 22-57, 21-58, 20-59, 18-62, 17-63, 16-64, 15-65, 14-66, 13-67, 12-68, 11-69, 10-71, 25-54, 26-53, 27-51, 28-50 REACTIONS.All bearings 45-9-0. (lb) - Max Horz 80=-144(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 39, 61, 60, 41, 56, 57, 58, 62, 63, 64, 65, 66, 67, 68, 71, 72, 73, 74, 75, 76, 77, 78, 54, 53, 51, 50, 49, 48, 47, 46, 45, 44, 43 except 80=-318(LC 4), 79=-199(LC 5), 40=-146(LC 4) Max Grav All reactions 250 lb or less at joint(s) 80, 39, 61, 42, 41, 55, 56, 57, 58, 59, 62, 63, 64, 65, 66, 67, 68, 69, 71, 72, 73, 74, 75, 76, 77, 78, 54, 53, 51, 50, 49, 48, 47, 46, 45, 44, 43, 40 except 79=330(LC 4) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 8-9=-19/255, 9-10=-18/282, 10-11=-20/303, 11-12=-1/283, 12-13=-1/283, 13-14=-1/283, 14-15=-1/283, 15-16=-1/283, 16-17=-1/283, 17-18=-1/283, 18-19=-1/283, 19-20=-0/286, 20-21=-0/286, 21-22=-0/286, 22-23=-0/286, 23-24=-1/286, 24-25=-20/306, 25-26=-18/287, 26-27=-18/259 NOTES-(16-17) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Bearing at joint(s) 61, 41 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE05 Truss Type Piggyback Base Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744396 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:51 2019 Page 2 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-FL0s?8sU0GYfsmSJ0T7e5LPZF38eu3Ra4YLYp0yzCjY NOTES-(16-17) 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 39, 61, 60, 41, 56, 57, 58, 62, 63, 64, 65, 66, 67, 68, 71, 72, 73, 74, 75, 76, 77, 78, 54, 53, 51, 50, 49, 48, 47, 46, 45, 44, 43 except (jt=lb) 80=318, 79=199, 40=146. 13) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 80, 39, 62, 63, 64, 65, 66, 67, 68, 69, 71, 72, 73, 74, 75, 76, 77, 78, 79, 40. 14) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 16) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 17) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE06 Truss Type Common Structural Gable Qty 2 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744397 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:52 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-kYaECUt6nZgVUw1VZAetdZxpMTXMdajjJC56LTyzCjX Scale = 1:13.8 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 4x6 2x4 2x4 2x4 3-2-93-0-0 3-0-0 -0-9-4 0-9-4 1-6-0 1-6-0 3-0-0 1-6-0 3-9-4 0-9-4 0-5-41-11-40-5-412.00 12 Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [4:0-2-6,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.10 0.05 0.01 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.00 (loc) 4 5 4 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 11 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=124/3-0-0, 4=124/3-0-0, 6=85/3-0-0 Max Horz 2=-39(LC 4) Max Uplift 2=-43(LC 6), 4=-49(LC 7) Max Grav 2=124(LC 1), 4=124(LC 1), 6=91(LC 2) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss GE11 Truss Type Common Supported Gable Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744398 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:54 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-gwh?dAuNIBwDjEBuhbgLi_1AMGCD5Sx0nWaDPLyzCjV Scale = 1:61.2 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 4x6 3x8 3x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 5x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 3x8 17-9-1 3 30-0-0 30-0-0 -0-11-4 0-11-4 15-0-0 15-0-0 30-0-0 15-0-0 30-11-4 0-11-4 0-6-148-0-140-6-146.00 12 Plate Offsets (X,Y)-- [2:0-0-4,0-0-9], [2:0-0-9,0-5-12], [2:0-3-8,Edge], [9:0-3-0,0-3-0], [17:0-3-0,0-3-0], [24:0-0-4,0-0-9], [24:0-0-9,0-5-12], [24:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.06 0.02 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.00 0.01 (loc) 25 25 24 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 159 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 30-0-0. (lb) - Max Horz 2=-78(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 2, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26 Max Grav All reactions 250 lb or less at joint(s) 2, 36, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 24 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26. 9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 24. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss M02 Truss Type Monopitch Qty 10 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744399 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:54 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-gwh?dAuNIBwDjEBuhbgLi_14qG8J5UP0nWaDPLyzCjV Scale = 1:28.0 1 2 4 3 2x4 3x6 3x4 3x6 5-11-8 5-11-8 5-11-8 5-11-8 1-10-84-10-44-6-120-3-84-10-46.00 12 Plate Offsets (X,Y)-- [3:Edge,0-2-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.42 0.27 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.05 -0.11 -0.00 (loc) 3-4 3-4 3 l/defl >999 >603 n/a L/d 240 180 n/a PLATES MT20 Weight: 20 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF-S Stud *Except* 1-4: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)4=228/0-3-8, 3=228/0-1-8 Max Horz 4=137(LC 5) Max Uplift 3=-43(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Bearing at joint(s) 3 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss PB01 Truss Type Piggyback Qty 18 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744400 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:55 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-87FNqWv?3U24LOm4FJCaFBZJ7gXPqweA?AJmyoyzCjU Scale = 1:29.6 2 3 4 5 6 10 9 8 1 7 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 16-0-0 16-0-0 8-0-0 8-0-0 16-0-0 8-0-0 -0-0-43-11-124-0-00-1-00-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.19 0.09 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 41 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 1=-37(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 2, 6, 10, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7, 2, 6 except 9=276(LC 1), 10=319(LC 10), 8=319(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 4-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 2, 6, 10, 8. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss PBE01 Truss Type Piggyback Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744401 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:57 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-4VN7FBxFb6IoahvSMjE2KcfgeUEQIqYTTUot0gyzCjS Scale = 1:29.8 Sheet Front Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 1 11 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-0-0 16-0-0 8-0-0 8-0-0 16-0-0 8-0-0 -0-0-43-11-124-0-00-1-00-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.12 0.06 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 1=-37(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 2, 10, 16, 17, 18, 14, 13, 12. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss PBE02 Truss Type Piggyback Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744402 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:58 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-YhxWTXytMPQfCrUfwRlHtqBrOuaf1Hnch7YQY7yzCjR Scale = 1:29.8 Sheet Back Full Sheathing 1 Ply 1/2RyDOW8 2 3 4 5 6 7 8 9 10 18 17 16 15 14 13 12 1 11 4x6 3x4 3x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-0-0 16-0-0 8-0-0 8-0-0 16-0-0 8-0-0 -0-0-43-11-124-0-00-1-00-1-86.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.12 0.06 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 11 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 51 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 1=-37(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 11, 2, 10, 16, 17, 18, 14, 13, 12 Max Grav All reactions 250 lb or less at joint(s) 1, 11, 2, 10, 15, 16, 17, 18, 14, 13, 12 FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Gable requires continuous bottom chord bearing. 5) Gable studs spaced at 1-4-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 11, 2, 10, 16, 17, 18, 14, 13, 12. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T01 Truss Type Common Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744403 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:59 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-0uVugtyV7jYWp?3rU8GWP1ktAHqsmjulwnHz5ZyzCjQ Scale = 1:49.5 1 2 3 4 5 8 7 6 4x6 2x4 2x4 3x8 6x6 6x6 8-0-0 8-0-0 16-0-0 8-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 3-6-08-2-03-6-07.00 12 Plate Offsets (X,Y)-- [2:0-2-8,Edge], [4:0-2-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.70 0.44 0.11 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.09 -0.22 0.00 (loc) 7-8 7-8 6 l/defl >999 >859 n/a L/d 240 180 n/a PLATES MT20 Weight: 68 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)8=714/0-5-8, 6=714/0-5-8 Max Horz 8=-220(LC 4) Max Uplift 8=-61(LC 6), 6=-61(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-527/115, 3-4=-527/115, 2-8=-646/127, 4-6=-646/127 WEBS 2-7=-14/328, 4-7=-14/328 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T02 Truss Type Roof Special Qty 5 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744404 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:22:59 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-0uVugtyV7jYWp?3rU8GWP1kpGHkdmXwlwnHz5ZyzCjQ Scale = 1:49.5 1 2 3 4 5 6 7 14 13 12 11 10 9 8 4x6 4x8 2x4 3x4 2x4 2x4 3x4 2x4 4x8 3x8 5x8 5x8 2-4-0 2-4-0 8-0-0 5-8-0 13-8-0 5-8-0 16-0-0 2-4-0 -1-3-4 1-3-4 2-4-0 2-4-0 8-0-0 5-8-0 13-8-0 5-8-0 16-0-0 2-4-0 17-3-4 1-3-4 3-6-08-2-03-6-00-10-07.00 12 Plate Offsets (X,Y)-- [2:0-4-1,Edge], [6:0-4-1,0-0-0], [8:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.95 0.78 0.88 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.18 -0.46 0.34 (loc) 11 10-11 8 l/defl >999 >408 n/a L/d 240 180 n/a PLATES MT20 Weight: 73 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 2-14,6-8: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 1-11-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)14=713/0-5-8, 8=713/0-5-8 Max Horz 14=221(LC 5) Max Uplift 14=-62(LC 6), 8=-62(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-408/110, 3-4=-481/114, 4-5=-481/114, 5-6=-408/110, 2-14=-544/107, 6-8=-544/107 BOT CHORD 11-12=-166/276, 10-11=0/251 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 14, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). we seal non-triangulated stuff all the time. i agree it would be better with diagonals but there is nothing sturucturall wrong with this. July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T03 Truss Type Piggyback Base Qty 3 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744405 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:01 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-zGce5Z_mfKoE3JDEbZI_VSpEy5NfETY2O5m49RyzCjO Scale = 1:119.2 1 2 3 4 5 6 7 8 9 10 11 12 13 1426252423 22 21 20 19 18 17 16 15 5x6 6x10 6x8 5x6 8x8 5x6 5x6 3x6 3x6 5x6 3x6 5x8 6x6 5x8 6x6 5x8 4x8 5x8 6x6 6x6 5x6 3x6 3x6 4x6 7-5-9 7-5-9 13-5-0 5-11-7 21-7-10 8-2-10 31-10-4 10-2-10 37-7-10 5-9-6 45-11-8 8-3-13 54-3-5 8-3-13 59-1-8 4-10-3 65-3-4 6-1-12 -0-11-4 0-11-4 7-5-9 7-5-9 13-5-0 5-11-7 21-7-10 8-2-10 31-10-4 10-2-10 37-7-10 5-9-6 45-11-8 8-3-13 54-3-5 8-3-13 59-1-8 4-10-3 65-3-4 6-1-12 66-2-8 0-11-4 0-6-1411-4-110-3-142-0-011-4-116.00 12 3.00 12 3.50 12 Plate Offsets (X,Y)-- [2:0-2-2,0-1-5], [8:0-5-8,0-2-12], [13:0-3-4,Edge], [16:0-2-8,0-3-0], [18:0-2-8,0-3-0], [20:0-3-8,0-2-0], [23:0-2-8,0-3-0], [25:0-2-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.62 0.93 0.74 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.36 -0.91 -0.06 (loc) 22-23 22-23 21 l/defl >614 >244 n/a L/d 240 180 n/a PLATES MT20 Weight: 305 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 *Except* 11-14: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 7-21,6-22,8-21,8-20,9-20: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-11 oc purlins, except 2-0-0 oc purlins (10-0-0 max.): 6-8. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-21, 6-23, 6-22, 8-21, 9-20, 11-18 REACTIONS.All bearings 0-3-8 except (jt=length) 2=0-7-4. (lb) - Max Horz 2=112(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 2, 13 except 25=-163(LC 6), 15=-190(LC 7) Max Grav All reactions 250 lb or less at joint(s) 13 except 2=444(LC 10), 21=1752(LC 1), 25=1499(LC 10), 15=1474(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-549/174, 3-5=-13/474, 5-6=-416/276, 6-7=0/376, 7-8=0/378, 8-9=-555/374, 9-11=-1230/381, 11-12=-1365/320, 12-13=-54/435 BOT CHORD 2-26=-99/456, 25-26=-84/405, 23-25=-348/106, 22-23=0/269, 20-21=0/387, 18-20=-158/1044, 16-18=-226/1304, 15-16=-372/82, 13-15=-372/82 WEBS 21-22=-926/103, 7-22=-596/187, 3-26=0/320, 3-25=-793/173, 5-25=-1113/246, 5-23=-16/716, 6-22=-383/0, 8-21=-893/0, 8-20=-43/697, 9-20=-855/216, 9-18=0/430, 11-18=-274/71, 11-16=-436/184, 12-16=-316/1747, 12-15=-1331/307 NOTES-(10-11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 13 except (jt=lb) 25=163, 15=190. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Continued on page 2 July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T03 Truss Type Piggyback Base Qty 3 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744405 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:01 2019 Page 2 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-zGce5Z_mfKoE3JDEbZI_VSpEy5NfETY2O5m49RyzCjO 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T07 Truss Type Piggyback Base Qty 2 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744406 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:02 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-RTA0Iv?OQex5gSoQ9HqD1gMNrVmXzw2CclWehuyzCjN Scale = 1:101.7 1 2 3 4 5 6 7 8 9 10 11 1223222120 19 18 17 16 15 14 132425262728 5x6 5x8 3x6 5x8 3x4 3x12 2x4 3x6 3x6 3x6 3x6 3x8 3x6 5x8 3x6 3x6 3x6 3x6 2x4 5x6 3x8 4x6 6-7-15 6-7-15 13-0-6 6-4-7 23-3-0 10-2-10 29-0-6 5-9-6 37-4-4 8-3-13 48-6-4 11-2-0 56-8-0 8-1-12 6-7-15 6-7-15 13-0-6 6-4-7 18-1-11 5-1-5 23-3-0 5-1-5 29-0-6 5-9-6 37-4-4 8-3-13 45-8-1 8-3-13 50-7-9 4-11-7 56-8-0 6-0-7 57-7-4 0-11-4 2-10-89-4-111-0-1311-4-110-3-142-0-011-4-116.00 12 3.00 12 Plate Offsets (X,Y)-- [1:0-2-0,0-1-8], [3:0-3-0,0-2-0], [6:0-5-8,0-2-4], [11:0-3-4,Edge], [15:0-2-8,0-1-8], [22:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.73 0.76 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.51 -0.97 -0.05 (loc) 19-20 19-20 18 l/defl >550 >289 n/a L/d 240 180 n/a PLATES MT20 Weight: 252 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E *Except* 14-16: 2x4 SPF No.2 WEBS 2x3 SPF No.2 *Except* 5-18,4-20,4-19,6-18,6-17,7-17: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-13. WEBS 1 Row at midpt 5-18, 2-20, 4-19, 6-18, 7-17 REACTIONS.All bearings 0-3-8. (lb) - Max Horz 23=-189(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 23, 11 except 13=-197(LC 7) Max Grav All reactions 250 lb or less at joint(s) 11 except 23=1032(LC 10), 18=2327(LC 1), 13=1608(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1083/280, 2-3=-921/335, 3-4=-736/333, 4-5=0/379, 5-6=0/381, 6-7=-629/376, 7-9=-1243/346, 9-10=-106/576, 1-23=-961/235 BOT CHORD 20-22=-37/903, 19-20=-1/456, 17-18=0/457, 15-17=-121/1028, 13-15=-129/636 WEBS 18-19=-1346/68, 5-19=-357/113, 4-20=0/580, 4-19=-949/10, 6-18=-1043/0, 6-17=-22/776, 7-17=-750/170, 7-15=0/308, 9-15=0/413, 9-13=-1619/430, 10-13=-476/171, 1-22=-157/930 NOTES-(9-10) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 23, 11 except (jt=lb) 13=197. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 10) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T08 Truss Type Common Qty 12 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744407 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:02 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-RTA0Iv?OQex5gSoQ9HqD1gMWIVvyz5OCclWehuyzCjN Scale = 1:13.8 1 2 3 4 5 3x4 2x4 2x4 1-6-0 1-6-0 3-0-0 1-6-0 -0-9-4 0-9-4 1-6-0 1-6-0 3-0-0 1-6-0 3-9-4 0-9-4 0-5-41-11-40-5-412.00 12 Plate Offsets (X,Y)-- [2:0-2-6,0-1-0], [3:0-2-0,Edge], [4:0-2-6,0-1-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.13 0.16 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 2-4 2-4 4 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 10 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=163/0-3-8, 4=163/0-3-8 Max Horz 2=-39(LC 4) Max Uplift 2=-37(LC 6), 4=-37(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T10 Truss Type Piggyback Base Qty 8 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744408 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:04 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-NrInja0eyFBowmypGish65RlbIQ5RquV43?kmmyzCjL Scale = 1:80.8 1 2 3 4 5 6 7 8 9 10 22 21 20 19 18 17 16 15 14 13 12 112324252627 5x6 5x8 3x6 3x4 3x16 MT18HS 2x4 3x6 3x6 2x4 2x4 6x8 3x4 3x6 3x6 3x8 3x6 5x8 3x6 3x8 3x6 5x6 4x6 6-7-15 6-7-15 13-0-6 6-4-7 23-3-0 10-2-10 29-0-6 5-9-6 36-10-3 7-9-13 44-8-0 7-9-13 45-9-0 1-1-0 6-7-15 6-7-15 13-0-6 6-4-7 18-1-11 5-1-5 23-3-0 5-1-5 29-0-6 5-9-6 36-10-3 7-9-13 44-8-0 7-9-13 45-9-0 1-1-0 2-10-89-4-1111-4-111-0-611-4-116.00 12 Plate Offsets (X,Y)-- [1:0-2-0,0-1-8], [3:0-3-0,0-2-0], [6:0-6-0,0-2-8], [12:0-2-8,0-3-0], [14:0-2-8,0-1-8], [21:0-2-8,0-1-8] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.59 0.89 0.70 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.52 -0.99 -0.03 (loc) 18-19 18-19 17 l/defl >538 >283 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 232 lb FT = 20% GRIP 169/123 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 15-17,18-20: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 5-17,4-19,4-18,6-17,6-16,7-16: 2x4 SPF No.2 9-13,10-11,10-12: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-15 oc purlins, except end verticals, and 2-0-0 oc purlins (6-0-0 max.): 3-6. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 5-17, 2-19, 4-18, 6-17, 7-16, 7-12 REACTIONS.(lb/size)22=1033/0-5-8, 17=2248/0-3-8, 11=974/Mechanical Max Horz 22=-143(LC 4) Max Uplift 22=-78(LC 6), 11=-121(LC 7) Max Grav 22=1033(LC 10), 17=2248(LC 1), 11=975(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1086/239, 2-3=-921/283, 3-4=-736/286, 4-5=0/295, 5-6=0/296, 6-7=-580/293, 7-9=-1034/337, 9-10=-854/182, 1-22=-964/202, 10-11=-941/169 BOT CHORD 19-21=-67/906, 18-19=-26/458, 16-17=-2/422, 14-16=-105/842 WEBS 17-18=-1345/108, 5-18=-357/113, 9-12=-444/233, 4-19=0/576, 4-18=-945/53, 6-17=-954/17, 6-16=-6/689, 7-16=-578/139, 12-14=-101/837, 1-21=-119/932, 10-12=-249/1069 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22 except (jt=lb) 11=121. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T22 Truss Type Common Qty 9 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744409 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:05 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-r2s9xw1GjZJfXwX?qPNwfI_v0ipdAOreIjkIIDyzCjK Scale = 1:52.8 1 2 3 4 5 6 7 8 9 12 11 101314 3x6 4x6 3x6 6x8 3x12 4x6 2x4 4x6 2x4 6x8 10-0-6 10-0-6 19-11-10 9-11-4 30-0-0 10-0-6 -0-11-4 0-11-4 7-6-9 7-6-9 15-0-0 7-5-7 22-5-7 7-5-7 30-0-0 7-6-9 30-11-4 0-11-4 0-6-148-0-140-6-146.00 12 Plate Offsets (X,Y)-- [2:0-0-4,0-0-9], [2:0-0-9,0-4-7], [2:0-3-8,Edge], [8:0-0-4,0-0-9], [8:0-0-9,0-4-7], [8:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.68 0.68 0.27 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.42 -0.63 0.08 (loc) 10-12 10-12 8 l/defl >846 >569 n/a L/d 240 180 n/a PLATES MT20 Weight: 98 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 WEDGE Left: 2x4 SPF-S Stud, Right: 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-2-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)2=1354/0-3-8, 8=1354/0-3-8 Max Horz 2=-78(LC 7) Max Uplift 2=-92(LC 6), 8=-92(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2266/297, 3-5=-2022/318, 5-7=-2022/318, 7-8=-2266/297 BOT CHORD 2-12=-165/1910, 10-12=-13/1291, 8-10=-165/1910 WEBS 5-10=-70/798, 7-10=-393/211, 5-12=-70/798, 3-12=-393/211 NOTES-(7-8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T23 Truss Type Common Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744410 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:05 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-r2s9xw1GjZJfXwX?qPNwfI_xaiosAKHeIjkIIDyzCjK Scale = 1:48.9 1 2 3 4 5 6 9 8 71011 2x4 4x10 3x6 3x16 MT18HS 4x6 2x4 4x6 4x8 10-1-3 10-1-3 20-0-0 9-10-13 5-0-0 5-0-0 12-5-7 7-5-7 20-0-0 7-6-9 20-11-4 0-11-4 5-6-148-0-140-6-146.00 12 Plate Offsets (X,Y)-- [5:0-0-4,0-0-9], [5:0-0-9,0-4-7], [5:0-3-8,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.58 0.72 0.57 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.45 -0.77 0.02 (loc) 7-9 7-9 5 l/defl >529 >306 n/a L/d 240 180 n/a PLATES MT20 MT18HS Weight: 72 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-8: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 WEDGE Right: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-5-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-9 REACTIONS.(lb/size)9=939/0-3-8, 5=907/0-3-8 Max Horz 9=-194(LC 4) Max Uplift 9=-45(LC 7), 5=-78(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1119/206, 4-5=-1356/180 BOT CHORD 7-9=0/421, 5-7=-63/1110 WEBS 2-7=-72/878, 4-7=-413/219, 2-9=-742/61 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9, 5. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T31 Truss Type Piggyback Base Qty 4 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744411 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:07 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-nQ_vLc3XEAZNnEgNyqPOkj3HwWT1eAMxm1DPN5yzCjI Scale = 1:118.5 1 2 3 4 5 6 7 8 9 10 11 12 13 1426252423 22 21 20 19 18 17 16 15 27 28 29 30 4x6 6x6 6x8 4x6 8x8 4x6 4x8 5x6 3x8 3x4 5x6 3x6 5x8 6x6 5x8 6x8 6x6 5x8 4x8 5x8 6x6 6x8 5x8 3x6 3x6 4x6 7-1-13 7-1-13 13-1-4 5-11-7 21-3-14 8-2-10 31-6-8 10-2-10 31-8-4 0-1-12 37-3-14 5-7-10 45-7-12 8-3-13 53-11-9 8-3-13 58-9-12 4-10-3 64-11-8 6-1-12 7-1-13 7-1-13 13-1-4 5-11-7 21-3-14 8-2-10 26-6-7 5-2-9 31-6-8 5-0-1 37-3-14 5-9-6 45-7-12 8-3-13 53-11-9 8-3-13 58-11-1 4-11-7 64-11-8 6-0-7 65-10-12 0-11-4 0-8-1211-4-110-3-142-0-011-4-116.00 12 3.00 12 3.50 12 Plate Offsets (X,Y)-- [1:0-2-15,0-7-6], [1:0-0-14,0-1-13], [8:0-5-12,0-3-0], [13:0-3-4,Edge], [16:0-2-8,0-3-0], [18:0-2-8,0-3-0], [20:0-3-8,0-2-0], [25:0-2-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.52 0.74 0.79 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.55 -0.98 -0.07 (loc) 22-23 22-23 21 l/defl >405 >227 n/a L/d 240 180 n/a PLATES MT20 Weight: 305 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 *Except* 11-14: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 22-24: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 7-21,8-21,8-20,9-20: 2x4 SPF No.2 WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-2-2 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 5-8. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-21, 5-23, 6-22, 8-21, 9-20, 11-18 REACTIONS.All bearings 0-3-8. (lb) - Max Horz 1=-113(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 13 except 25=-176(LC 6), 15=-192(LC 7) Max Grav All reactions 250 lb or less at joint(s) 13 except 1=361(LC 10), 21=2100(LC 1), 25=1572(LC 10), 15=1587(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-556/152, 2-4=-28/475, 4-5=-522/273, 5-6=-356/291, 6-7=0/377, 7-8=0/378, 8-9=-681/383, 9-11=-1454/391, 11-12=-1553/333, 12-13=-55/478 BOT CHORD 1-26=-86/464, 25-26=-71/412, 23-25=-346/123, 22-23=-7/251, 20-21=0/505, 18-20=-166/1244, 16-18=-239/1489, 15-16=-414/82, 13-15=-414/82 WEBS 21-22=-1014/72, 7-22=-370/109, 2-26=0/321, 2-25=-798/172, 4-25=-1231/265, 4-23=-31/815, 6-22=-545/14, 8-21=-1154/17, 8-20=-43/908, 9-20=-965/215, 9-18=0/438, 11-18=-258/77, 11-16=-502/186, 12-16=-330/1976, 12-15=-1436/312 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T31 Truss Type Piggyback Base Qty 4 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744411 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:07 2019 Page 2 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-nQ_vLc3XEAZNnEgNyqPOkj3HwWT1eAMxm1DPN5yzCjI NOTES-(11-12) 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 13 except (jt=lb) 25=176, 15=192. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T32 Truss Type Piggyback Base Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744412 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:08 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-GdXIZy39?UhEPNFaVXxdHxcODwpFNeC4?hzyvXyzCjH Scale = 1:118.5 1 2 3 4 5 6 7 8 9 10 11 12 13 1426252423 22 21 20 19 18 17 16 15 27 28 29 30 4x6 6x6 6x8 4x6 8x8 4x6 4x8 5x6 3x8 3x4 5x6 3x6 4x6 6x6 5x8 6x8 6x6 5x8 5x8 5x8 6x6 6x6 4x8 5x6 3x6 3x6 7-1-13 7-1-13 13-1-4 5-11-7 21-3-14 8-2-10 31-6-8 10-2-10 31-8-4 0-1-12 37-3-14 5-7-10 45-7-12 8-3-13 53-11-9 8-3-13 56-9-12 2-10-3 64-11-8 8-1-12 7-1-13 7-1-13 13-1-4 5-11-7 21-3-14 8-2-10 26-6-7 5-2-9 31-6-8 5-0-1 37-3-14 5-9-6 45-7-12 8-3-13 53-11-9 8-3-13 56-9-12 2-10-3 58-11-1 2-1-5 64-11-8 6-0-7 65-10-12 0-11-4 0-8-123-0-1311-4-110-3-142-0-011-4-116.00 12 3.00 12 3.50 12 Plate Offsets (X,Y)-- [1:0-2-15,0-7-6], [1:0-0-14,0-1-13], [8:0-5-12,0-3-0], [13:0-3-4,Edge], [16:0-2-8,0-3-0], [18:0-2-8,0-3-0], [20:0-3-8,0-2-0], [25:0-2-8,0-3-0] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.74 0.74 0.75 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.55 -0.98 -0.03 (loc) 22-23 22-23 21 l/defl >405 >227 n/a L/d 240 180 n/a PLATES MT20 Weight: 304 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2 *Except* 11-14: 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 22-24: 2x4 SPF 2100F 1.8E WEBS 2x3 SPF No.2 *Except* 7-21,8-20,9-20,8-21: 2x4 SPF No.2 WEDGE Left: 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 4-11-7 oc purlins, except 2-0-0 oc purlins (6-0-0 max.): 5-8. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 7-21, 5-23, 6-22, 9-20, 8-21 REACTIONS.All bearings 0-3-8. (lb) - Max Horz 1=-113(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 13 except 25=-176(LC 6), 15=-192(LC 7) Max Grav All reactions 250 lb or less at joint(s) except 1=361(LC 10), 21=1991(LC 1), 13=256(LC 1), 25=1576(LC 10), 15=1577(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-558/153, 2-4=-28/473, 4-5=-526/275, 5-6=-360/292, 6-7=0/379, 7-8=0/380, 8-9=-637/376, 9-11=-1240/354, 11-12=-724/204, 12-13=-26/351 BOT CHORD 1-26=-86/466, 25-26=-71/413, 23-25=-344/122, 22-23=-6/257, 20-21=0/464, 18-20=-134/1053, 16-18=-104/690, 15-16=-276/61, 13-15=-276/61 WEBS 21-22=-1008/73, 7-22=-365/110, 2-25=-798/172, 2-26=0/322, 6-22=-543/14, 4-25=-1234/266, 9-18=0/298, 11-18=-32/383, 11-16=-667/190, 4-23=-32/818, 8-20=-23/786, 9-20=-771/183, 8-21=-1042/0, 12-15=-1382/309, 12-16=-196/1176 NOTES-(11-12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses ("BCSI"), jointly produced by WTCA and TPI. For project specific guidance, consult with project engineer/architect/general contractor. MiTek assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Continued on page 2 July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss T32 Truss Type Piggyback Base Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744412 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:08 2019 Page 2 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-GdXIZy39?UhEPNFaVXxdHxcODwpFNeC4?hzyvXyzCjH NOTES-(11-12) 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 13 except (jt=lb) 25=176, 15=192. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 12) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 LENNAR 44 CLAY Job Reference (optional) I37744413 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:09 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-kp5gmI4nmop50Xqm3FSsp88YgJEN65iEDLiVR_yzCjG Scale = 1:49.5 1 2 3 4 5 9 8 7 6101112131415161718 5x6 3x6 3x6 10x10 10x10 8x8 8x8 5-5-3 5-5-3 10-6-13 5-1-11 16-0-0 5-5-3 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 3-6-08-2-03-6-07.00 12 Plate Offsets (X,Y)-- [2:0-2-8,Edge], [4:0-2-8,Edge], [6:Edge,0-2-8], [7:0-5-0,0-6-4], [8:0-5-0,0-6-4] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.82 0.43 0.73 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.07 -0.16 0.01 (loc) 7-8 7-8 6 l/defl >999 >999 n/a L/d 240 180 n/a PLATES MT20 Weight: 208 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x8 SP 2400F 2.0E WEBS 2x3 SPF No.2 *Except* 2-8,4-7: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)9=7730/0-5-8, 6=7843/0-5-8 Max Horz 9=-215(LC 3) Max Uplift 9=-325(LC 5), 6=-329(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6134/298, 3-4=-6148/299, 2-9=-6379/300, 4-6=-6392/300 BOT CHORD 7-8=-169/4231 WEBS 3-7=-143/3021, 3-8=-141/2986, 2-8=-206/5952, 4-7=-207/5964 NOTES-(10-11) 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x3 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x3 - 1 row at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 9=325, 6=329. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2014 lb down and 76 lb up at 2-0-12, 2014 lb down and 76 lb up at 4-0-12, 2008 lb down and 76 lb up at 6-0-12, 1974 lb down and 76 lb up at 8-0-12, 2011 lb down and 76 lb up at 10-0-12, and 2014 lb down and 76 lb up at 12-0-12, and 2014 lb down and 76 lb up at 14-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 11) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). LOAD CASE(S) Standard Continued on page 2 July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss TG01 Truss Type Common Girder Qty 1 Ply 2 LENNAR 44 CLAY Job Reference (optional) I37744413 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:09 2019 Page 2 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-kp5gmI4nmop50Xqm3FSsp88YgJEN65iEDLiVR_yzCjG LOAD CASE(S) Standard 1) Dead + Roof Live (balanced) + Uninhab. Attic Storage: Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-2=-60, 2-3=-60, 3-4=-60, 4-5=-60, 9-13=-20, 13-15=-60, 6-15=-20 Concentrated Loads (lb) Vert: 10=-2014(B) 11=-2014(B) 12=-2008(B) 14=-1974(B) 16=-2011(B) 17=-2014(B) 18=-2014(B) July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V01 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744414 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:10 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-C?f2_e5PX5xyehPydyz5MMhtujewrhjNS?S3_QyzCjF Scale = 1:38.9 1 2 3 4 5 6 7 12 11 10 9 81314 2x4 2x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 16-0-0 16-0-0 -1-3-4 1-3-4 8-0-0 8-0-0 16-0-0 8-0-0 17-3-4 1-3-4 1-5-136-1-131-5-137.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-R 0.15 0.16 0.17 DEFL. Vert(LL) Vert(TL) Horz(TL) in -0.00 -0.01 0.00 (loc) 7 7 8 l/defl n/r n/r n/a L/d 180 120 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-0-0. (lb) - Max Horz 12=-152(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 12, 8, 11, 9 Max Grav All reactions 250 lb or less at joint(s) 12, 8 except 10=460(LC 1), 11=403(LC 10), 9=403(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-11=-261/131, 5-9=-261/131 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 8, 11, 9. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V02 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744415 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:11 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-gCDQB_61IP3pGr_9BgUKvZE267z2a96WhfBcWsyzCjE Scale = 1:33.7 1 2 3 4 5 9 8 7 63x6 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 0-0-7 0-0-7 17-7-15 17-7-8 8-10-0 8-10-0 17-7-15 8-10-0 0-0-45-1-130-0-47.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.19 0.23 0.10 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 17-7-1. (lb) - Max Horz 1=-112(LC 4) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=399(LC 10), 6=399(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-290/134, 4-6=-294/135 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V03 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744416 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:11 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-gCDQB_61IP3pGr_9BgUKvZE?J7?4a9VWhfBcWsyzCjE Scale = 1:27.1 1 2 3 4 5 8 7 63x4 4x6 3x4 2x4 2x4 2x4 2x4 2x4 14-2-13 14-2-13 7-1-6 7-1-6 14-2-13 7-1-6 0-0-44-1-130-0-47.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.37 0.10 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 36 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 14-2-13. (lb) - Max Horz 1=89(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 8, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=272(LC 1), 8=315(LC 10), 6=315(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 8, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V04 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744417 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:12 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-8OnoPK6f3jBgt?ZLkN?ZRnmAPXIhJdwgvJx92JyzCjD Scale = 1:20.8 1 2 3 43x8 4x6 3x8 2x4 10-9-10 10-9-10 5-4-13 5-4-13 10-9-10 5-4-13 0-0-43-1-130-0-47.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.35 0.26 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 25 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=179/10-9-10, 3=179/10-9-10, 4=419/10-9-10 Max Horz 1=66(LC 5) Max Uplift 1=-18(LC 6), 3=-22(LC 7), 4=-1(LC 6) Max Grav 1=181(LC 10), 3=181(LC 11), 4=419(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V05 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744418 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:13 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-caLBcf7Hq0JXV98XI5Wo__JLIwUJ246p8zgjalyzCjC Scale = 1:15.5 1 2 3 2x4 3x4 2x4 7-4-8 7-4-8 3-8-4 3-8-4 7-4-8 3-8-4 0-0-42-1-130-0-47.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.34 0.88 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 14 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=252/7-4-8, 3=252/7-4-8 Max Horz 1=-43(LC 4) Max Uplift 1=-12(LC 6), 3=-12(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V06 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744419 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:13 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-caLBcf7Hq0JXV98XI5Wo__JPTwf6246p8zgjalyzCjC Scale = 1:8.5 1 2 3 2x4 3x4 2x4 0-0-7 0-0-7 3-11-6 3-10-15 1-11-11 1-11-11 3-11-6 1-11-11 0-0-41-1-130-0-47.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.07 0.19 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 7 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 3-11-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=115/3-10-8, 3=115/3-10-8 Max Horz 1=-19(LC 4) Max Uplift 1=-5(LC 6), 3=-5(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V11 Truss Type Valley Qty 2 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744420 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:14 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-4mvZp?8wbKRO7Ijkso11WCsbcK0SnXMzNdQG7ByzCjB Scale = 1:10.3 1 2 3 2x4 3x4 2x4 0-0-4 0-0-4 2-11-13 2-11-9 1-5-15 1-5-15 2-11-13 1-5-15 0-0-41-5-150-0-412.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.04 0.12 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 2-11-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=91/2-11-5, 3=91/2-11-5 Max Horz 1=27(LC 5) Max Uplift 1=-2(LC 7), 3=-2(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V24 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744421 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:15 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-YzSx1L9YMeZFkSHwQVZG3POjjkLRWze6cH9qfdyzCjA Scale = 1:26.5 1 2 3 5 43x6 2x4 2x4 2x4 2x4 9-2-2 9-2-2 0-0-44-7-16.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.21 0.13 0.06 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 4 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 26 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x3 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=144/9-2-2, 4=112/9-2-2, 5=419/9-2-2 Max Horz 1=133(LC 5) Max Uplift 4=-13(LC 5), 5=-76(LC 6) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-301/180 NOTES-(7-8) 1) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 7) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 8) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V25 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744422 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:16 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-190JEh9A7xh6Mcs6zD4VcdxvS8h7FORGqxvNB4yzCj9 Scale = 1:41.1 1 2 3 4 5 6 7 13 12 11 10 9 83x4 4x6 3x4 4x6 2x4 2x4 2x4 2x4 2x4 2x4 2x4 2x4 24-4-4 24-4-4 12-2-2 12-2-2 24-4-4 12-2-2 0-0-46-1-10-0-46.00 12 Plate Offsets (X,Y)-- [9:0-1-4,0-0-0], [10:0-3-0,0-1-4], [10:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.15 0.17 0.16 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 24-4-4. (lb) - Max Horz 1=56(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 12, 13, 9, 8 Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 11=453(LC 1), 12=413(LC 10), 13=324(LC 1), 9=408(LC 11), 8=324(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-259/130, 5-9=-259/130 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 13, 9, 8. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V26 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744423 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:16 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-190JEh9A7xh6Mcs6zD4Vcdxss8cCFPYGqxvNB4yzCj9 Scale = 1:34.3 1 2 3 4 5 9 8 763x8 4x6 3x6 4x8 2x4 2x4 2x4 2x4 20-4-4 20-4-4 10-2-2 10-2-2 20-4-4 10-2-2 0-0-45-1-10-0-46.00 12 Plate Offsets (X,Y)-- [6:0-1-4,0-0-0], [7:0-4-0,0-1-4], [7:0-0-0,0-1-12] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.38 0.48 0.08 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 54 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 20-4-4. (lb) - Max Horz 1=47(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 9=481(LC 10), 6=483(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-342/163, 4-6=-347/164 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 9, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V27 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744424 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:17 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-VLahS1AouFpy_mRIXwbk8qU44Y1K_s0P3bewjWyzCj8 Scale = 1:27.8 1 2 3 4 5 9 8 7 63x4 4x6 3x4 3x6 2x4 2x4 2x4 2x4 2x4 16-4-4 16-4-4 8-2-2 8-2-2 16-4-4 8-2-2 0-0-44-1-10-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.16 0.17 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 42 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* 5-7: 2x4 SPF-S Stud OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.All bearings 16-4-4. (lb) - Max Horz 1=37(LC 5) Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 6 Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 8=263(LC 1), 9=358(LC 10), 6=357(LC 11) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-9=-265/131, 4-6=-268/132 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 6. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V28 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744425 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:18 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-zY84fNBQfZypbw0V5e6_h20ADxKtjJEYIFOUGyyzCj7 Scale = 1:21.0 1 2 3 43x12 4x8 3x12 2x4 12-4-4 12-4-4 6-2-2 6-2-2 12-4-4 6-2-2 0-0-43-1-10-0-46.00 12 Plate Offsets (X,Y)-- [1:0-9-11,Edge], [3:0-3-3,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-SH 0.45 0.34 0.07 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 28 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=198/12-4-4, 3=198/12-4-4, 4=492/12-4-4 Max Horz 1=-27(LC 4) Max Uplift 1=-21(LC 6), 3=-25(LC 7), 4=-3(LC 6) Max Grav 1=202(LC 10), 3=202(LC 11), 4=492(LC 1) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-296/103 NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V29 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744426 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:18 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-zY84fNBQfZypbw0V5e6_h20BfxN3jKnYIFOUGyyzCj7 Scale = 1:15.8 1 2 3 4 2x4 4x6 2x4 2x4 8-4-4 8-4-4 4-2-2 4-2-2 8-4-4 4-2-2 0-0-42-1-10-0-46.00 12 LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.42 0.14 0.04 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 18 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF No.2 OTHERS 2x3 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=144/8-4-4, 3=144/8-4-4, 4=279/8-4-4 Max Horz 1=-17(LC 4) Max Uplift 1=-20(LC 6), 3=-23(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE. Job B19902007 Truss V30 Truss Type Valley Qty 1 Ply 1 LENNAR 44 CLAY Job Reference (optional) I37744427 8.220 s Nov 16 2018 MiTek Industries, Inc. Thu Jul 11 07:23:19 2019 Page 1 Builders First Source, mooresville,in ID:ZO2O6XrKYh0WyIllVI6XoNznWgg-RkiStjC2Qs4gD4bhfLdDDFZRmLh0SnbiWv71oPyzCj6 Scale = 1:8.3 1 2 3 2x4 3x4 2x4 4-4-4 4-4-4 2-2-2 2-2-2 4-4-4 2-2-2 0-0-41-1-10-0-46.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2003/TPI2002 CSI. TC BC WB Matrix-P 0.08 0.22 0.00 DEFL. Vert(LL) Vert(TL) Horz(TL) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 8 lb FT = 20% GRIP 169/123 LUMBER- TOP CHORD 2x4 SPF-S Stud BOT CHORD 2x4 SPF-S Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 4-4-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS.(lb/size)1=124/4-4-4, 3=124/4-4-4 Max Horz 1=-8(LC 4) Max Uplift 1=-6(LC 6), 3=-6(LC 7) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES-(8-9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 90mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp B; Enclosed; MWFRS (low-rise) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI-B1 9) It is extremely important to properly install temporary lateral restraint and diagonal bracing, in accordance with BCSI-B2 or using proprietary methods (e.g. Stabilizer, etc.). July 11,2019 PRODUCT CODE APPROVALSLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal Injury (Drawings not to scale)© 2012 MiTek® All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015edge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W 4 - 6 W3-6W3 - 7 W2-7W1-7C1-8 C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD TOP CHORD 87654321BOTTOM CHORDSTOP CHORDSBEARING4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes *Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8WEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.dimensions shown in ft-in-sixteenths