HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property 14285 JAMES DEAN DR CARMEL, IN 46033 Model: SOHO Community: THE GROVE AT LEGA( TG047 (AS DESIGNED) THE GROVE AT LEGACY 47 Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,237 $165 $331 $1,733 $769 $0 $2,502 Requirements C-M, Energy Solutions As Designed S1,176 S155 S331 $1,662 S769 so $2,431 C4405.3 Performance-based compliance passes by 4.1% R402.4.12 Air Leakage Testing Air sealing is 5.51) ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 4.1 As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 7/3119 at 11:01 AM Ekotrope RATER - Version 3.1.0.2209 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 14285 JAMES DEAN DR MISTPI MA:Is] CARMEL, IN 46033 Builder: PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor R-30 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5.5 ACH50 Window U -Value: 0.3, SHGC: 0.26 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 136 CFM @ 25Pa (5.971100 s.f.) Total Duct Leakage 182.0 CFM @ 25Pa Heating Furnace • Natural Gas • 80 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 713119 at 11:01 AM Ekotrope RATER - Version 3.1.0.2209 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 14285 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOHO Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC TG047 (AS DESIGNED) THE GROVE AT LEGACY 47 General Building Information Conditioned Area (sq ft) 2,279 Conditioned Volume (cubic ft) 20,511 Insulated Shell Area (sq ft) 5,768 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB(1,009 s.f., 164 ft. exterior perimeter) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor El Name: GARAGE (253 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I El Name: AMBIENT (109 s.f.) R-0 continuous insulation, R-30 cavity insulation Insulation Grade: I Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (2,414 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIGAR (315 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 14285 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOHO Community: THE GROVE AT LEGA[ Builder PYATT BUILDERS, LLC TG047 (AS DESIGNED) THE GROVE AT LEGACY 47 Name: CONDIATTIC (142 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (82 s.f.) R: 11.691 L Name: CONDIATTIC (73 s.f.) R: 11.691 Roof Name: MAIN (1,371 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing inspection Status Results are projected E] Name: FRONT (78 s.f.), U: 0.300, SHGC: 0.26, Orientation: EAST E] Name: BACK (88 s.f.), U:0.300, SHGC: 0.26, Orientation: WEST El Name: SLIDER (80 s.f.), U:0.300, SHGC: 0.26, Orientation: WEST El Name: RIGHT SIDE (95 s.f.), U:0.300, SHGC: 0.26, Orientation: NORTH El Name: LEFT SIDE (104 s.f.), U:0.300, SHGC: 0.26, Orientation: SOUTH C-M, Energy Solutions 2 Energy Code Inspection Checklist Property Organization 14285 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOHO Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC TG047 (AS DESIGNED) THE GROVE AT LEGACY 47 Skylight None Present Mechanical Ventilation None Present Mechanical Equipment Inspection Status Results are projected 0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 80 AFUE Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 1,880 CFM50 (5.50 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 136 CFM @ 25 Pa (5.97 J 100 s.f.) Total Duct Leakage specified as 182.0 CFM @ 25Pa (Post -Construction) C", Energy Solutions 3 Energy Code Inspection Checklist Property Organization 14285 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOHO Community: THE GROVE AT LEGA( Builder PYATT BUILDERS, LLC TG047 (AS DESIGNED) THE GROVE AT LEGACY 47 Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 14285 JAMES DEAN DR CARMEL, IN 46033 Model: SOHO Community: THE GROVE AT LEGACY 47 TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 GeneraFBuilding Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder PYATT BUILDERS, LLC 3 2 2;279 Yes 20;511 1 Single family detached SOHO THE GROVE AT LEGACY 47 5A None Present None Present Masonry Area C-M, Energy Solutions n SLAB R-10, 1'down, 2' in 164 On Grade 1.23 0 1,009.0 R' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 2' in Wood Frame /Other No 2 1 10 No 10.00 1 Building Summary Library Type Surface Calor Property Organization Inspection Status C-MEnergy Solutions 14285 JAMES DEAN DR TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons G1 R-15 BATT, OSB Medium Model: SOHO CONDIATTIC Community: THE GROVE AT LEGACY 47 Builder Attic PYATT BUILDERS, LLC Medium 142.0 P[' TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 Unconditioned, attached garage G1 R-15 Gar Walls ramed Floor 315.0 HY Name Library Type Carpet R Floor Grade Surface Area Location AMBIENT R-30, GR1 1.23 Above Grade 109.0 R' Exposed Exterior GARAGE R-30, GR1 1.23 253.0 R' Unconditioned, attached Above Grade garage Framed Floor Library List Name Effective R -value 27.493 Rim Joist i Name Library Type Surface Area Location CONDIAMB G1 R-15, OSB 82.0 fF Exposed Exterior CONDIATTIC G1 R-15, OSB 73.0 fl' Attic Rim Joist Library List Name Effective Insulation R -value G1 R-15, OSB 11.691 Wall Name Library Type Surface Calor Surface Area Location CONDIAMB Exposed Exterior G1 R-15 BATT, OSB Medium 2.414.0 P[' CONDIATTIC Attic G1 R-15 BATT, OSB Medium 142.0 P[' CONDIGAR Unconditioned, attached garage G1 R-15 Gar Walls Medium 315.0 HY 2 Building Summary Property Organization Inspection Status C-MEnergy Solutions 14285 JAMES DEAN DR TSI Energy Solutions Results are projected CARMEL, IN 46033 Matthew Timmons Model: SOHO Community: THE GROVE AT LEGACY 47 Builder PYATT BUILDERS, LLC TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 FWall-fibrary List Name Effective R -value G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 Glazing Name Library Type Wall Assignment Foundation Wall Overhang Assignment Depth Overhang Ft Top To Overhang Ft To Bottom Orientation Surface Area BACK U-.30, SHGG26 CONDIAMB 0 0 0 West 88.0 fF FRONT U-.30, SHGG26 CONDIAMB 0 0 0 East 78.0 fF LEFT SIDE U-.30, SHGG26 CONDIAMB 0 0 ❑ South 104.0 fts RIGHT SIDE U-.30, SHGG26 CONDIAMB 0 0 ❑ North 95.0 ft SLIDER U-30, SHGG26 CONDIAMB 0 0 ❑ West 80.0 f, Glazing Library List Name Shg c U factor U-.30, SHGC-26 026 0.300 Skylight None Present Skylight Library List None Present Building Summary Property Organization 14285 JAMES DEAN DR TSI Energy Solutions CARMEL, IN 46033 Matthew Timmons Model: SOHO Community: THE GROVE AT LEGACY 47 Builder PYATT BUILDERS, LLC TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 Fopaque DoolrV��� Name Library Type Wall Assignmen FRONT Steel Door CONDIAMB GARAGE Steel Door CONDIGAR ndatPon Wall Assignment Opaque Door Library List Name Effective U -factor 0.182 Inspection Status Results are projected Solar Absorptance C-M, Energy Solutions PF M r Surface Area Location 0.9 0.75 Medium 20.0 fr Exposed Exterior 0.9 0.75 Medium 18.0 fr Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location Vf.] Tiles F•,1AIN R-38 Blown, GR1 '.371 No Medium 1.377.0 ftp Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value ?•8 3 :a l No 38268 Whole House Infiltratic Infiltration 5.5 ACH at 50 Pa Mechanical Ventilation Blower -door tested 4 M Building Summary Property 14285 JAMES DEAN DR CARMEL, IN 46033 Model: SOHO Community: THE GROVE AT LEGACY 47 TG047 (AS DESIGNED) THE GROVE AT LEGACY 47 ighting "MOM % Interior Fluorescent °% Interior LED Lighting 0 C-M Energy Solutions Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder PYATT BUILDERS, LLC % Exterior Fluorescent % Exterior LED Lighting % Garage FI uorescenI Lighting Lighting 0 Onsite Generation mmmft� m None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present C Conditioning Equipment Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load I Location Air conditioner (2) CA13NA030 0% 100% 0% Conditioned Space Fuel4red air 310AAV042090 100% o% 0% Conditioned Space distribution (1) Water Heating (3) RE350` 0% o% 100% Conditioned Space A Building Summary Property 14285 JAMES DEAN DR CARMEL, IN 46033 Model: SOHO Community: THE GROVE AT LEGACY 47 TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 quipment Type: Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC 310AAV042090 gquipment Type: CA13NA030 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Natural Gas Forced Air PSG (Single Speed) 80 AFU E 71 No 848 i Electric Forced Air PSG (Single Speed) 13 SEER 27.4 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 Inspection Status Results are projected C-M, Energy Solutions Building Summary Property 14285 JAMES DEAN DR CARMEL, IN 46033 Model: SOHO Community: THE GROVE AT LEGACY 47 TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 1butivn System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area r] ]uct Area [ft2] 5 to Outdoors akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC Forced Air Fuel -fired air distribution (1) Air conditioner (2) 2279 2 3❑ 30 461.5 170.9 136 CFM @ 25Pa (5.971 100 s.f.) 182 Post -Construction Yes Attic (well vented; under insulation) 50 50 Conditioned Space 5❑ 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 14285 JAMES DEAN DR CARMEL, IN 46033 Model: SOHO Community: THE GROVE AT LEGACY 47 TG047 [AS DESIGNED] THE GROVE AT LEGACY 47 ater Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization TSI Energy Solutions Matthew Timmons Builder PYATT BUILDERS, LLC Standard No 55 No No 20 No Electric Timer Controls ff"W 704 kWh/Year 0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � Inspection Status Results are projected C-M, Energy Solutions ,�