Loading...
HomeMy WebLinkAbout19050113 Site Plan"BASE HOUSE STANDARD FEATURES" MODEL: MONACO LOT # 14 ±13,175 SF 8'FULLBASEMENT 7 CAR COURTYARD PAD 848.3 PER PLAN 5'X7' DECK MFFE 848.9 PER PLAN MFPG 848.7 PER PLAN "SELECTE EATURE,S" ELEV C01 - LEFT HAW 9' FULL BASEME BRICK WRAP (1) 4'X4' WINDOW WEL MODIFIED PATIO Note: Minimum Front Yard - 15' Minimum Side Yard - 0' Minimum Between Bldgs - 6' Aggregate Minium - 10' Minimum Rear Yard - 20' ® = Proposed Grade Drainage Flow — — = Proposed Silt Fence Note: Contractor should verify window well location with Field Manager. Note: Contractor should verify sump pit location with Field Manager. " Conc Flatwork Sq. Ft = ±1136 Pubiic Walk Sq Ft = ±984 Sod Sq Yds = ±668 Seeding Sq Ft = ±3,981 " (Drive, Apron, T Walk, Patio, Stoops) (PORCH NOT INCLUDED) HSM 16 SAN MH 50 TC=847.29 ta\5 41 ryG rr� J, W. Z 211 V)F- FC) Hazard Note: ✓ Lot Number 14 lies within that Special Flood Hazard Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057CO208G, dated November 19, 2014). Note: T N O r //,_ ate . Gar. FFE = 848.8 1 st Fir FFE = 850.6 TOW = 849.6 Bsmt FFE = 840.8 Drive Slope =±6.5% HSM 15 23Ol SAN MH TC=848.39 / 6.17+ a h 1 0A s> roc co Iwo cAt� GASB 2. {UNXG1 a 3 2' a m M pOR Cc w ' 3.0' � m d mOt4AGO SUMP pIT O a ppT10 25' D.&U.E. / 4 �. 20' B.S.L. �( 2,.3' STM SEWER —7 co SSD 4 ' 133.17' WATER LINE Contractor should verify site specific Information depicted hereon with the approved construction plans for this development in regards to sidewalk and handicap ramp placement, widths, and construction. Contractor should verify site specific information in regards to erosion control placement and materials. Also, Contractor should reference Architectural plans for foundation orientation and dimensions. The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.: failure to do so would result in the contractor/owners assumption of liability. 0 0 - Note: C.A."C" This document has been prepared for the benefit of the parties indicated hereon, for the express use of obtaining a residential building permit. This document has been prepared and based upon the construction documents, record drawings, and additional information prepared for this development by others. This document is not based upon a field survey and Coor Consulting does not warrant the accuracy or completeness of this information. Note: The lowest elevation to have gravity sanitary sewer service must be more than one (1) foot above the lowest top of casting elevation of either the first upstream or downstream manhole on the main line sewer to which the connection is made. Note: Manholes must remain accessible and at grade at all times. Note: Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and conditions within the building areas of this development have been provided andlor referenced on said documents. With the excavation of the proposed structure foundations, certain care and observations should be made in regard to such conditions as soil types and fluctuating water tables. During the excavation process should any unsuitable soils or ground water be witnessed, the builder shall be immediately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. �a�Q o���� 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 DATE: 0516119 JOB #2017-055.014 REVISIONS:2 HERITAGE AT SPRINGMILL SECTION 2 P.C. 5, SLIDE 728 INSTR. #2017047160 LOT !.,1 11193 VALESIDE CRESENT CARMEL, IN 46032 PLOT PLAN Prepared For: Pulte Pulte Homes of Indiana