HomeMy WebLinkAboutA111 Deconstruction-ArchitecturalDECONSTRUCTION LEGEND
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL WALL
i DOOR AND FRAME
— PARTIAL HEIGHT WALL
oo--co WINDOW/SIDELIGHT
77 DOOR AND FRAME
T T CEILING GRID AND
T iI LES, 2'X2'
7--r-r
x WINDOW/SIDELIGHT
F'T
T i'T SUPPLY AIR DIFFUSERS
cawwra
LIGHTSWITCH
T6?TO) ELECTRIC OUTLET(S)
DATA OR
b COMMUNICATION
OUTLET
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
GENERAL NOTES
I. REFER i0 ALL DECONSTRUCTION NOTES ON TITLE SHEET it 11.
2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE
CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR
BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR
REMOVAL, REFER TO THE DECONSTRUCTION MANAGEMENT
CHECKLIST.
3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN
ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW
FINISHES AS REQUIRED.
4. REMOVE EXISTING CEILING TILES, 2X4 LIGHT FIXTURES AND
RECESSED CAN FIXTURES THROUGHOUT, UNLESS NOTED
OTHERWISE. EXISTING CEILING GRID TO REMAIN. REFER TO
DECONSTRUCTION CHECKLIST FOR PROPER RECYCLING METHOD
FOR ALL LIGHT FIXTURES,
DECON. PLAN NOTES
8 REMOVE EXISTING CABINETRY AND COUNTERTOP. REFER TO
DECONSTRUCTION CHECKLIST FOR PROPER DISPOSAL METHOD.
D02 REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED.
D03 REMOVE EXISTING COAT ROD AND SHELF.
D04 EXISTING WORKSTATIONS TO REMAIN.
E�
CONTRACTOR TO CUT DOWN EXISTING WORKSTATION PARTIAL
D05 HEIGHT WALL ALONG EXTERIOR WINDOW LINE. CONTRACTOR TO
COORDINATE EXACT REQUIREMENTS WITH TENANT.
® AREA NOT IN CONTRACT
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�LJ'�BaT41WML_
DATE: \ 07/29/19
DECONSTRUCTION MANAGEMENT CHECKLIST
THIS CHECKLIST ONLY APPLIES TO ITEMS BEING REMOVED. REFER TO DECONSTRUCTION PLAN.
CO-MINGLE/LEED CONTAINER REQUIRED FOR RECYCLING.
CONTAINER:
ITEM BEING
«wU,
REMARKSREMOVEDLq
wi
oUrc
DOORS, FRAMES,
REUSE ALL EXISTING DOORS, FRAMES AND DOOR HARDWARE IN NEW
DOOR HARDWARE
LAYOUT WHERE POSSIBLE
METAL LIGHT BOXES
✓
CASEWORK UNIT
✓
CARPET TILE
✓
BROADLOOM CARPET
✓
APPLIANCES ✓
GENERAL SORTING REQUIREMENTS (AS APPLICABLE):
LEED CO -MINGLE RECYCLING CONTAINER: SHIPPING/PACKAGING, WOOD STUDS, WOOD TRIM, HVAC COMPONENTS,
CEILING GRID, METAL STUDS, WIRING/ CONDUIT, AND OUTLETS/SWITCHES
TRASH CONTAINER: DRYWALL, INSULATION, VINYL BASE AND _VT (LUXURY VINYL TILE), VCT, CEILING TILES,
WALLCOVERING
CARPET RECYCLING NOTES:
CARPET RECYCLING: KRUSE PICKUP AND RECYCLING FEES ARE TO BE PAID THROUGH SCHOTT DESIGN'S NO COST ADD
PROGRAM. THE DEMOLITION CREW/GENERAL CONTRACTOR WILL NO LONGER BE PAVING THE CARPET DISPOSAL
TIPPING FEES ATTHE LANDFILL. CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION.
1. CARPET BEING REMOVED TO BE RECYCLED VIA KRUSE CARPET RECYCLING, COORDINATE REQUIREMENTS AND PICK
UP WITH SUSAN SHAFER (317) 337-1950.
2. CARPET TILES SHOULD BE PALLETIZED; BROADLOOM SHOULD BE PILED NEATLY.
3. COLLECT DOCUMENTATION FROM KRUSE AS PROOF OF RECEIVAL, FORWARD TO THE GENERAL CONTRACTOR.
DECONSTRUCTION PLAN
0 2' 4' 8' 16'
� R4�
WALL TYPES
WALL
11111
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE R UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. TYPICAL WAI
STANDARD WALL
3%a" METAL STUDS AT 16" O.C.;
ONE LAYER OF 6% TYPE "X GYPSUM BOARD
EACH SIDE;
EXTEND W ALL TO UNDERSIDE OF CEILING
WALL WITH INSULATION
35/a" MEFAL STUDS AT 16"O.C.; -
ONE LAYER OF s% TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL i0 UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0 EACH SIDE OF WALL ABOVE
CEILING
DEMISING WALL TO DECK WITH INSULATION
32/g" METAL STUDS AT 16O.C.;
ONE LAYER OF Y" TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL i0 UNDERSIDE OF DECK;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2' -0' SOUND BATT INSULATION EACH
SIDE OF WALL ABOVE CEILING.
s
METAL STUD
EXIST NO WIP
MULLION
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
ARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
W7
WALL
®
PARTIAL HEIGHT WALL
aI WINDOW SIDELIGHT
57 DOOR AND FRAME
(SEE DOOR SON EDU LEI
WALL
® PARTIAL HEIGHT WALL
1~¢ WINDOW SIDELIGHT
77 DOOR AND FRAME
LINE OF EXISTING WINDOW NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
SILL COVER BELOW DEMOLI➢ON CAN BE SUBSTITUTED FOR NEW DOORS.
GENERAL NOTES
CONTINUOUS BEAD OF I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
ACOUSTICAL SEALANT 2, REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
EQUAL WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
n FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
WALL AT MULLION DETAIL
NOT TO SCALE PLAN NOTES
AREA NOT I N CONTRACT
AREA OF WORK
AOT ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
A02 CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING i0 NFPA 10.
A03 PROVIDE I6"DEEP WHITE MELAMINE ADJUSTABLE SHELVING ON
HEAVY DUTY KV BRACKETS AND STANDARDS (APPROX. 5 SHELVES)
A04 PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT,
A05 CONFIRM THAT EXISTING WALL MATCHES WALL TYPE'W3". IF NOT,
ALTER EXISTING WALLAS REQUIRED TO MATCH'W3".
8PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
8
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
P02 PROVIDE WATER LINE FOR REFRIGERATOR AND WATER COOLER.
CONFIRM LOCATION WITH TENANT.
ARCHITECTURAL PLAN
0 2' 4' 8' 16'
%==MMMEE�
�/
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
QO Q
N
LU
U z=
Z Q v�
a. F O
Q X~�
W N
ZW LU
LA. L� J I—Z
Z V III w
QIY
V_ N � U
r Z
LaLJ M
W O
Q U�
III
1111 GATE DESCRIPTION
06.17.19
REVIEW SET
07.03.19
PERMITSET
REVISIONS
PROJECT NUMBER
2018.498
PROD. MGR DRAWN BY
I BIN BIN
2ND FLOOR
DECONSTRUCTION PLAN/
ARCHITECTURAL
FLOOR PLAN
1
All