Loading...
HomeMy WebLinkAboutA121 Electrical & Reflected CeilingELECTRICAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX .N, ^N' POWER OUTLET, POWER OUTLET, QUADRUPLEX QUADRUPLEX J JUNCTION BOX J JUNCTION BOX OCEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, BLANK COVER PLATE BOX, OPEN QO BOX, OPEN P PROVIDE JUNCTION BOX P POWER AND DATA POLE D ABOVE CEILING FOR O POWER POLE CONNECTION. POWER POLE BY OTHERS. FLOOR BOX WITH POWER FLOOR BOX WITH POWER 5I41 AND DATA, FLUSH AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH FQ K JU NCTION BOX AND J b JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATON 10 OUTLET (PROVIDE BOX 4 OUTLET AND PULLSTRING ONLY) DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42' HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL PLAN NOTES E01 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT. E02 NO ELECTRICAL WORK IN THIS AREA. E03 IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOX TO NEW RECEPTACLE AS SHOWN. IF NOT POSSIBLE, REMOVE BLANK/OPEN BOX AND PROVIDE NEW RECEPTACLE ATTHIS LOCATION. E04 PROVIDE POWER AT THIS LOCATION FOR TENANT'S GARBAGE B DISPOSAL. ® AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�S2'�D*S41WML_ DATE: \ 07/29/19 GENERAL ELEC. NOTES I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRI➢CAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18' MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOT FY APPLICABLE PARTIES I F ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. ELECTRICAL PLAN 0 2' 4' 8' 16' RCP LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', FLUORESCENT, BUILDING STANDARD INDIRECT/DIRECT ® EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE ® EMERGENCY LIGHT FIXTURE $N LIGHT SWITCH $ LIGHT SWITCH $N3 LIGHT SWITCH, SWAY $3 LIGHT SWITCH, SWAY $ND LIGHT SWITCH, DIMMER $D LIGHT SWITCH, DIMMER $NE LIGHT SWITCH, EXHAUST LIGHT SWITCH, DIMMER $NP SWITCH, PROJECTOR $P SWITCH, PROJECTOR SCREEN SCREEN $NG SWITCH, GARBAGE $G SWITCH, GARBAGE DISPOSAL (ABOVE DISPOSAL COUNTERTOP( $NE SWITCH, EXHAUSTFAN $E SWITCH, EXHAUST FAN i — LIGHT CIRCUIT -' . LIGHT CIRCUIT CEILING GRID, I I I CEILING GRID, SUSPENDED, 2'x2' ---r--r- SUSPENDED, 2'x2' ❑RELOCATED DIFFUSER, ® DIFFUSER, -AY IN, 2'x2' LAY IN, 2'x2' RELOCATED DIFFUSER, fg] DIFFUSER, LAY IN, 1'x4' LAY IN, 1'x4' ® RELOCATED DIFFUSER, DIFFUSER, LAY -IN. 4'A' LAY -IN, 4'k4' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEI LING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. GENERAL NOTES PROVIDE N EW BUILDING STANDARD CEILING TILE AN D REUSE EXISTING CEILING GRID, UNLESS OTHERWISE NOTED. EXISTING GRID 152X2 AT 8'-5'A.F.F. TILES ARE 2X2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID. I. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 2. PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED PER NEMAANDIBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUTSHOWNIS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITEI ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES A LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTO TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRE SO THAT ADDITIONAL PLANS CAN BE FI LED AND MUST COMPLY I ALL APPLICABLE CODES. ® AREA NOT IN CONTRACT ❑ AREA OF WORK MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THATADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE I NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. RCP PLAN NOTES ROt TIE IN NEW LIGHT FIXTURES TO EXISTING CIRCUIT AND EXISTING LIGHT SWITCH. IF NOT POSSIBLE, PROVIDE NEW LIGHT SWITCH AS REQUIRED. RELOCATE DIFFUSERS & MECHANICAL DIFFUSER RELOCATION ^ `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION REFLECTED CEILING PLAN 0 2' 4' 8' 16' THIS DRAWING, ANDTHEIDEAS, DEIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRITTEN CONSENT OF SCHOTT DESIGN. aO Q N U HW Z~ Z a= a CD x F ~0� W N ZW LU LL LLU H Z Z Z UaJ w a > 012 V_ N � U r Z Lu M W O aUIiiiiiiiin SSUE DATE DESCRIPTION 06.17.19 REVIEW SET 07.03.19 PERMIT SET REVISIONS MARld DATE I DB IDESCRIP ION IN 0. AR10700017 STATE OF PROJECT NUMBER 2018.498 DRAWN BY I 2ND FLOOR ELECTRICAL PLAN/ REFLECTED CEILING PLAN A121