ENLARGED LIFE SAFETY PLAN
0 4' 8' 16,
nr`mmI1
BUSINESS
REMAINING SPACE OF 1,675 SF
AREA TO BE ALTERED TO MEET CODE IN SEPARATE
PROJECT SCOPE
® AREA NOT IN CONTRACT
❑ AREA OF WORK
CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
BUSINESS(
OCCUPANCY CLASSIFICATION
BUSINESS(
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
28,968 SF/FLOOR
X
1 4 STORIES
=
115,872 SF
TOTAL PROJECT AREA
2715 SF
SPACE TYPE AREA SF PER OCCUPANT I OCCUPLOAD
OCCUPANCY CALCULATIONS
GEN. OFFICE
2,715 SF
100
1 28
TOTAL OCCUPANTS IN PROJECT AREA 28
NUMBER OF EXITS
REQUIRED: I PROVIDED: I
SPRINKLER SYSTEM(YES/NO(
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
28,968 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED(
N/A
ASHRAE 90.1 SUMMARY
REQ UI REM ENTS W I LL B E M Ell IS EE REFLECTED C El LI N G PLAN(
BUILT BEFORE 19782
NO
BUILDING CONSTRUCTION TYPE
II-B
GENERAL NOTES
LI. REFER TO ARCHTECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXT SIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
LIFE SAFETY NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES(,
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE HEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
EP EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT. BUILDING STAIR LOCATION
c1 Fe FIRE EXTINGUISHER
OVERALL BUILDING
N OT TO SCALE >N
O
0.0 U
N V O
Z U
nr
0
w O M U
o C
V�
'vwJ c
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARETHE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WTHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
aaRa� O C)
Q N
V HW
Z~
Z a=
N
Q A F O
XLU
LUN
Z wW�O
LL LU j N Z
Z Vaw
Q >o�E
N � V_ J
r Z
LU M
LU O
Q U�
SSUE
DATE DESCRIPTION
06.17.19 REVIEW SET
07.03.19 PERMIT SET
REVISIONS
MARK DATE I DB
No.
AR10700017
STATE OF
PROJECT NUMBER
2018.498
DRAWN BY
BW
2ND FLOOR
LIFE SAFETY
L 100