Loading...
HomeMy WebLinkAboutA000.2\A1;1'-0{\H0.750000x;\S5#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" \A1;1'-0{\H0.750000x;\S5#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" TOP OF PLATEFIRST FLOOR FIRST FLOOR PL.SECOND FLOOR BOTTOM OF HEADER GARAGE PL. SECOND FLOOR PL. BOTTOM OF HEADER TOP OF CHIMNEY SHALL BE 2'-0" ABOVE THE HIGHEST POINT WITHIN A 10'-0" RADIUS SLOPED CHIMNEY CAP\PPER SPEC. ROOF SHINGLES1X6 FASCIA BRICK VENEER PER SPEC. SCALE 1/4" = 1'-0"REAR ELEVATION 129STONE HEAD PER SPEC.126126 STONE SILL 1x3 TRIM OVER 1x10 TRIM \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. 1210 1210 1210 1210 1210 \A1;1'-0{\H0.750000x;\S5#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" \A1;1'-0{\H0.750000x;\S5#8;}" \A1;9'-1{\H0.750000x;\S1#8;}" TOP OF PLATEFIRST FLOOR FIRST FLOOR PL.SECOND FLOOR BOTTOM OF HEADERSECOND FLOOR PL. BOTTOM OF HEADER SCALE 1/4" = 1'-0"FRONT ELEVATION \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. ROOF SHINGLES1X6 FASCIAFPYON #DTLB6X6X5 OR EQUAL SPACED AT 24" OR EQUAL BRICK VENEER PER SPEC. STONE HEAD PER SPEC. 6" STONE SILL SMOOTH PANEL 1X6 RAKE BRICK VENEER PER SPEC. 12" ROUND COLUMN PER SPEC. 8" STONE HEAD PER SPEC. 6" STONE SILL 6" STONE PER SPEC. 2030 FX WINDOW \A1;R9'-4{\H0.750000x;\S5#8;}" BRICK CORBEL, PER SPEC\P(SEE DETAIL) SMOOTH PANEL 1210 \A1;R7'-0{\H0.750000x;\S3#4;}" \A1;10'-10" \A1;15'-4{\H0.750000x;\S7#8;}"\A1;2'-0" 1210 1210 1210 1210 1210 SCALE 1/8" = 1'-0"ROOF PLAN \A1;1'-0"\PTYP. \A1;1'-0"\PTYP. \A1;1'-0"\PTYP.\A1;1'-0"\PTYP. \A1;1'-0"\A1;1'-0" \A1;1'-0"\A1;1'-0" MIN. 84 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"\A1;6'-0" \A1;6'-0" \A1;20'-0"\A1;6'-0" \A1;10'-0" 10:12 8:12 8:12 8:12 10:12 8:12 6:126:123:12 10:1210:12 10:12 10:12 10:12 1:1210:12 "E"352ROOF AREA:SQ. FT. "C"466ROOF AREA:SQ. FT. "B"410ROOF AREA:SQ. FT. 6:12 6:12 10:12 Elevation ATTIC VENT SCHEDULE{\C0;VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE\P** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS\P* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION} ROOF AREA "A"SQ FTG 2911 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.88 4.85 4.24 43.88 10 0 AT EAVE 5.82 4.85 5.42 56.12 0 78.00 TOTAL (MIN)9.70 9.70 9.65 100.00 HIGH - RIDGE VENT 3.88 4.85 4.50 45.38 0 0 36.00 AT EAVE 5.82 4.85 5.42 54.62 0 78.00 TOTAL (MIN)9.70 9.70 9.92 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B"SQ FTG 410 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.55 0.68 0.85 50.41 2 0 AT EAVE 0.82 0.68 0.83 49.59 0 12.00 TOTAL (MIN)1.37 1.37 1.68 100.00 HIGH - RIDGE VENT 0.55 0.68 0.75 47.37 0 0 6.00 AT EAVE 0.82 0.68 0.83 52.63 0 12.00 TOTAL (MIN)1.37 1.37 1.58 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "C"SQ FTG 466 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.62 0.78 0.85 46.56 2 0 AT EAVE 0.93 0.78 0.97 53.44 0 14.00 TOTAL (MIN)1.55 1.55 1.82 100.00 HIGH - RIDGE VENT 0.62 0.78 0.75 43.55 0 0 6.00 AT EAVE 0.93 0.78 0.97 56.45 0 14.00 TOTAL (MIN)1.55 1.55 1.72 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "E"SQ FTG 352 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.47 0.59 0.85 46.56 2 0 AT EAVE 0.70 0.59 0.97 53.44 0 14.00 TOTAL (MIN)1.17 1.17 1.82 100.00 HIGH - RIDGE VENT 0.47 0.59 0.75 43.55 0 0 6.00 AT EAVE 0.70 0.59 0.97 56.45 0 14.00 TOTAL (MIN)1.17 1.17 1.72 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 16" Cornice Termination w/ Corbel Corner (Brick Veneer) \A1;1'-4" \A1;8"\A1;1" CORBEL SCALE 3/8" = 1'-0" BRICK VENEER WALLS +0"{\C6;SIDE}{\C6;FRONT} BRICK VENEER WALLS +0"LINE OF BRICK WALL BEYONDCORBEL BRICK COURSES (8 TIMES) BRICK SOLDIER COURSE TUCKED UNDER FRIEZE3 ROWS OF STACK BRICK COURSE 1x3 TRIM OVER 1x10 TRIM BRICK SOLDIER COURSE LINE OF BRICK VENEER WALL BEYOND ROOF SHINGLES OVER CAP FLASHINGBOXED RAKE PLAN NAME SHEET COMMUNITY NAME PRODUCTION MANAGER LAWSON COMMUNITY ID RELEASE DATE:DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME SPECIFICATION LEVEL GARAGE HANDING REV # PROJECT TYPE CURRENT NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS ARCHITECT OF RECORD:ENGINEER OF RECORD: 05/13/2019Joel Hampshire (c) Copyright PulteGroup, Inc. - 2011 Indiana Division11590 N. Meridian St, Suite 530Carmel, Indiana 46032SINGLE FAMILY West Clay LOT 314 ---- GARAGE LEFT Red Plan 5 1815.0000 -- 5271 MULHERN & KULPGODUCO DESIGN - ARCHITECTS PLOTTED: June 28, 2019 / Annie Lee / PLAN-5271-IN-WCLY-EL-IT3S.DWG 7.03A IT3SItalianate 3SFront & Rear Elevations1------------------------------ 07/26/19 Adam Schriner