TOP OF PLATEFIRST FLOOR
FIRST FLOOR PL.SECOND FLOOR
BOTTOM OF HEADER
GARAGE PL.
SECOND FLOOR PL.
BOTTOM OF HEADER
TOP OF CHIMNEY SHALL BE 2'-0" ABOVE THE HIGHEST POINT WITHIN A 10'-0" RADIUS
SLOPED CHIMNEY CAP\PPER SPEC.
ROOF SHINGLES1X6 FASCIA
BRICK VENEER PER SPEC.
SCALE 1/4" = 1'-0"REAR ELEVATION
129STONE HEAD PER SPEC.126126
STONE SILL
1x3 TRIM OVER 1x10 TRIM
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
1210
1210 1210
1210 1210
\A1;1'-0{\H0.750000x;\S5#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"
\A1;1'-0{\H0.750000x;\S5#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"
TOP OF PLATEFIRST FLOOR
FIRST FLOOR PL.SECOND FLOOR
BOTTOM OF HEADERSECOND FLOOR PL.
BOTTOM OF HEADER
SCALE 1/4" = 1'-0"FRONT ELEVATION
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
ROOF SHINGLES1X6 FASCIAFPYON #DTLB6X6X5 OR EQUAL SPACED AT 24" OR EQUAL
BRICK VENEER PER SPEC.
STONE HEAD PER SPEC.
6" STONE SILL
SMOOTH PANEL
1X6 RAKE
BRICK VENEER PER SPEC.
12" ROUND COLUMN PER SPEC.
8" STONE HEAD PER SPEC.
6" STONE SILL
6" STONE PER SPEC.
2030 FX WINDOW
\A1;R9'-4{\H0.750000x;\S5#8;}"
BRICK CORBEL, PER SPEC\P(SEE DETAIL)
SMOOTH PANEL
1210
\A1;R7'-0{\H0.750000x;\S3#4;}"
\A1;10'-10"
\A1;15'-4{\H0.750000x;\S7#8;}"\A1;2'-0"
1210 1210 1210
1210 1210
SCALE 1/8" = 1'-0"ROOF PLAN
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.
\A1;1'-0"\PTYP.\A1;1'-0"\PTYP.
\A1;1'-0"\A1;1'-0"
\A1;1'-0"\A1;1'-0"
MIN. 84 SQ. IN. OF VENTILATION REQUIRED AT EAVE FOR ROOF "D"\A1;6'-0"
\A1;6'-0"
\A1;20'-0"\A1;6'-0"
\A1;10'-0"
10:12
8:12
8:12
8:12 10:12
8:12
6:126:123:12
10:1210:12
10:12
10:12 10:12 1:1210:12
"E"352ROOF AREA:SQ. FT.
"C"466ROOF AREA:SQ. FT.
"B"410ROOF AREA:SQ. FT.
6:12
6:12
10:12
Elevation
ATTIC VENT SCHEDULE{\C0;VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE\P** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS\P* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION}
ROOF AREA "A"SQ FTG 2911 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 3.88 4.85 4.24 43.88 10 0
AT EAVE 5.82 4.85 5.42 56.12 0 78.00
TOTAL (MIN)9.70 9.70 9.65 100.00
HIGH -
RIDGE VENT 3.88 4.85 4.50 45.38 0 0 36.00
AT EAVE 5.82 4.85 5.42 54.62 0 78.00
TOTAL (MIN)9.70 9.70 9.92 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "B"SQ FTG 410 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.55 0.68 0.85 50.41 2 0
AT EAVE 0.82 0.68 0.83 49.59 0 12.00
TOTAL (MIN)1.37 1.37 1.68 100.00
HIGH -
RIDGE VENT 0.55 0.68 0.75 47.37 0 0 6.00
AT EAVE 0.82 0.68 0.83 52.63 0 12.00
TOTAL (MIN)1.37 1.37 1.58 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "C"SQ FTG 466 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.62 0.78 0.85 46.56 2 0
AT EAVE 0.93 0.78 0.97 53.44 0 14.00
TOTAL (MIN)1.55 1.55 1.82 100.00
HIGH -
RIDGE VENT 0.62 0.78 0.75 43.55 0 0 6.00
AT EAVE 0.93 0.78 0.97 56.45 0 14.00
TOTAL (MIN)1.55 1.55 1.72 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
ROOF AREA "E"SQ FTG 352 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 0.47 0.59 0.85 46.56 2 0
AT EAVE 0.70 0.59 0.97 53.44 0 14.00
TOTAL (MIN)1.17 1.17 1.82 100.00
HIGH -
RIDGE VENT 0.47 0.59 0.75 43.55 0 0 6.00
AT EAVE 0.70 0.59 0.97 56.45 0 14.00
TOTAL (MIN)1.17 1.17 1.72 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
16" Cornice Termination w/ Corbel Corner (Brick Veneer)
\A1;1'-4"
\A1;8"\A1;1" CORBEL
SCALE 3/8" = 1'-0"
BRICK VENEER WALLS +0"{\C6;SIDE}{\C6;FRONT}
BRICK VENEER WALLS +0"LINE OF BRICK WALL BEYONDCORBEL BRICK COURSES (8 TIMES)
BRICK SOLDIER COURSE TUCKED UNDER FRIEZE3 ROWS OF STACK BRICK COURSE
1x3 TRIM OVER 1x10 TRIM
BRICK SOLDIER COURSE
LINE OF BRICK VENEER WALL BEYOND ROOF SHINGLES OVER CAP FLASHINGBOXED RAKE
PLAN NAME
SHEET
COMMUNITY NAME
PRODUCTION MANAGER
LAWSON COMMUNITY ID
RELEASE DATE:DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN IDLEGACY PLAN NUMBER / NAME
SPECIFICATION LEVEL
GARAGE HANDING
REV #
PROJECT TYPE
CURRENT
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
ARCHITECT OF RECORD:ENGINEER OF RECORD:
05/13/2019Joel Hampshire
(c) Copyright PulteGroup, Inc. - 2011
Indiana Division11590 N. Meridian St, Suite 530Carmel, Indiana 46032SINGLE FAMILY
West Clay
LOT 314
----
GARAGE LEFT
Red
Plan 5
1815.0000
--
5271
MULHERN & KULPGODUCO DESIGN - ARCHITECTS
PLOTTED: June 28, 2019 / Annie Lee / PLAN-5271-IN-WCLY-EL-IT3S.DWG
7.03A
IT3SItalianate 3SFront & Rear Elevations1------------------------------
07/26/19
Adam Schriner