HomeMy WebLinkAboutWCC 314 - Plot Plan"BASE HOUSE STANDARD FEATURES"
MODEL: 5271 (LOT SPECIFIC)
ELEV 5 - LEFT HAND
9' FULL BASEMENT
MASONRY WRAP
2 CAR SIDE ENTRY GARAGE
1 CAR FRONT ENTRY GARAGE
(2) 4'X4' WINDOW WELLS
Contractor should verify sump
pit location with Field Manage
Note:
LOT # 314
±15,005 SF
NO PAD PER PLAN
MFFE 894.4 PER PLAN
MFPG 892.5 PER PLAN
Minimum Front Yard - 20'
Minimum Side Yard - 5' or 8% (_
8.0')
Minimum SY Aggregate - 15 or 18%
(= 18.0')
Minimum Rear Yard - 20'
The lowest elevation to have gravity sanitary sewer service must
be more than one (1) foot above the lowest top of casting
elevation of either the first upstream or downstream manhole on
the main line sewer to which the connection is made.
Flood Hazard Note:
Lot Number 314 lies within Flood Hazard Zone "X" per the
scaled location on the Flood Insurance Rate Maps for Hamilton
County, Indiana (Community Panel 18057CO205G, dated
November 19, 2014).
Note:
This document has been prepared for the benefit of the parties indicated hereon,
for the express use of obtaining a residential building permit.
This document has been prepared and based upon the construction documents,
record drawings, and additional information prepared for this development by
others. This document is not based upon a field survey and Coor Consulting
does not warrant the accuracy or completeness of this information.
do�dd�o�g odQg
p o T a� o o 1M
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 05/28/19 JOB #2004-060.314CHELM REVISIONS:3
Gar. FFE = 895.0
1 st Fir FFE = 896.8
TOW = 895.8
Bsmt FFE = 887.0
Drive Slope = ±10%
LQ,OUunsd HQIPP h
N'MIt
�E o
No.
S0557
STATE OF
SU 0cj
Contractor should verify site specific information depicted hereon with the
approved construction plans for this development in regards to sidewalk and
handicap ramp placement, widths, and construction. Contractor should verify site
specific information in regards to erosion control placement and materials. Also,
Contractor should reference Architectural plans for foundation orientation and
dimensions.
Unless otherwise stated hereon, no information pertaining to but not
The contractor/owner should verify existing conditions prior to construction. Any
varying field conditions or any discrepancy with the information contained hereon
should be immediately reported to COOR Consulting & Land Services, Corp.;
failure to do so would result in the contractor/owners assumption of liability.
Note:
Manholes must remain accessible and at grade at all times.
Note:
Unless otherwise stated hereon, no information pertaining to but not limited to,
fluctuating water tables elevations, soil types, and conditions within the building
areas of this development have been provided and\or referenced on said
documents. With the excavation of the proposed structure foundations, certain
care and observations should be made in regard to such conditions as soil types
and fluctuating water tables. During the excavation process should any
unsuitable soils or ground water be witnessed, the builder shall be immediately
notified for further examination and consultation. At the builders discretion,
additional construction techniques may be necessary to alleviate future
problems.
VILLAGE OF
WESTCLAY
SECTION V02 -B
P.C. 4, SLIDE 110
INSTR. #200600042602
LOT # 314
12668 ROSEBERRY DRIVE
CARMEL, IN 46032
PLOT PLAN
Prepared For:
Pulte
Pulte Homes of Indiana
"BASE HOUSE STANDARD FEATURES"
MODEL: 5271 (LOT SPECIFIC)
ELEV 5 - LEFT HAND
9' FULL BASEMENT
MASONRY WRAP
2 CAR SIDE ENTRY GARAGE
1 CAR FRONT ENTRY GARAGE
(2) 4'X4' WINDOW WELLS
Contractor should verify sump
pit location with Field Manag_w
Note:
LOT # 314
±15=5 SF
NO PAD PER PLAN
MFFE 894.4 PER PLAN
MFPG 892.5 PER PLAN
Minimum Front Yard - 20'
Minimum Side Yard - 5' or 8% (_
8.0')
Minimum SY Aggregate - 15 or 18%
(= 18.0')
Minimum Rear Yard - 20'
The lowest elevation to have gravity sanitary sewer service must
be more than one (1) foot above the lowest top of casting
elevation of either the first upstream or downstream manhole on
the main line sewer to which the connection is made.
Flood Hazard Note:
Lot Number 314 lies within Flood Hazard Zone "X" per the
scaled location on the Flood Insurance Rate Maps for Hamilton
County, Indiana (Community Panel 18057CO205G, dated
November 19, 2014).
Note:
This document has been prepared for the benefit of the parties indicated hereon,
for the express use of obtaining a residential building permit.
This document has been prepared and based upon the construction documents,
record drawings, and additional information prepared for this development by
others. This document is not based upon a field survey and Coor Consulting
does not warrant the accuracy or completeness of this information.
Oor��a0�or�g��a�c 00c��
a
303 WEST MAIN STREET KNIGHTSTOWN. INDIANA
(888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692
DATE: 05/28/19 JOB #2004-060.314CHELM REVISIONS:3
Gar. FFE = 895.0
1 st Fir FFE = 896.8
TOW = 895.8
Bsmt FFE = 887.0
Drive Slope = ±10%
La��a�c�c H@Nh
Q30
tt,"1M'1"',
No. Cp .
S0557
STATE OF10
;
Contractor should verify site specific information depicted hereon with the
approved construction plans for this development in regards to sidewalk and
handicap ramp placement, widths, and construction. Contractor should verify site
specific information in regards to erosion control placement and materials. Also,
Contractor should reference Architectural plans for foundation orientation and
dimensions.
Unless otherwise stated hereon, no information pertaining to but not
The contractor/owner should verify existing conditions prior to construction. Any
varying field conditions or any discrepancy with the information contained hereon
should be immediately reported to COOR Consulting & Land Services, Corp.;
failure to do so would result in the contractor/owners assumption of liability.
Note:
Manholes must remain accessible and at grade at all times.
Note:
Unless otherwise stated hereon, no information pertaining to but not limited to,
fluctuating water tables elevations, soil types, and conditions within the building
areas of this development have been provided and\or referenced on said
documents. With the excavation of the proposed structure foundations, certain
care and observations should be made in regard to such conditions as soil types
and fluctuating water tables. During the excavation process should any
unsuitable soils or ground water be witnessed, the builder shall be immediately
notified for further examination and consultation. At the builders discretion,
additional construction techniques may be necessary to alleviate future
problems.
VILLAGE OF
WESTCLAY
SECTION V02 -B
P.C. 4, SLIDE 110
I N STR. #200600042602
LOT # 314
12668 ROSEBERRY DRIVE
CARMEL, IN 46032
PLOT PLAN
Prepared For:
Pulte �roui.
Pulte Homes of Indiana