HomeMy WebLinkAboutP001.1PLUMBING NOTES
I. ALL WORK SHALL BE DONE IN COMPLIANCE WITH THE FOLLOWING REGULATIONS,
CODES AND STANDARDS
2007 INDIANA BUILDING CODE
2007 INDIANA MECHANICAL CODE
2007 INDIANA PLUMBING CODE
OSHA REGULATIONS AND STANDARDS
NFPA STANDARDS
2. THE PLUMBING DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO INDICATE
GENERAL ARRANGEMENT OF EQUIPMENT, FIXTURES AND PIPING. DO NOT SCALE
DRAWINGS FOR EXACT LOCATION OF EQUIPMENT, PIPING ETC. UNLESS SPECIFICALLY
DIMENSIONED ON THE DRAWINGS, LOCATIONS SHALL BE DETERMINED IN THE FIELD.
MAKE REASONABLE MODIFICATIONS IN THE INSTALLATION SO ALL EQUIPMENT, PIPING,
ETC. FIT PROPERLY AND CAN BE SERVICED.
3. PLUMBING CONTRACTOR SHALL ARRANGE AND PAY FOR ALL PLUMBING
PERMITS AND INSPECTIONS AS REQUIRED BY LOCAL ORDINANCES.
4. PLUMBING CONTRACTOR SHALL KEEP ACCURATE RECORDS OF ALL UNDERGROUND
AND CONCEALED PIPING AND EQUIPMENT WHICH DEVIATED FROM DRAWINGS. AT
COMPLETION OF WORK, CONTRACTOR SHALL PRESENT TO THE OWNER'S
REPRESENTATIVE A MARKED SET OF CONSTRUCTION DOCUMENTS INDICATING CHANGES.
5. THE PLUMBING CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL
NECESSARY TO PERFORM HYDROSTATIC TESTS PER THE STATE PLUMBING CODE.
6. TOILET ROOM ACCESSORIES SHALL BE FURNISHED AND INSTALLED BY THE OWNER
7. INSTALL DIELECTRIC UNIONS,COUPLNGS OR INSULATED FLANGE KITS AT ALL JUNCTIONS
OF DISSIMILAR METAL PIPING SYSTEMS.
8. INSTALL INDIVIDUAL SHUTOFF VALVES AND UNIONS AT ALL PLUMBING FIXTURES AND
PIECES OF EQUIPMENT.
9. INSTALL PROPER ADAPTORS AT CHANGES IN PIPING MATERIALS.
10. PROVIDE P-TRAP WITH 3" MINIMUM TRAP SEAL AT FLOOR DRAINS. FORM TRAP WITH
PVC-DWV RETURN BEND AND LONG RADIUS ELL. SET FLOOR DRAINS 1/8" LOWER
THAN FINISH FLOOR.
It ALL VALVES SHALL BE INSTALLED N LOCATIONS WHERE THEY ARE ACCESSIBLE AND
ABLE TO BE OPERATED AND MAINTAINED.
12. IT 15 TI-E INTENT OF THESE OF THESE SPECIFICATIONS TO COVER FIRST CLASS
WORKMANSHIP THROUGHOUT. PERSONNEL SHALL BE THOROUGHLY TRAINED AND
EXPERIENCED IN THE PRODUCTS INVOLVED AND IN RECOMMENDED METHODS FOR THEIR
FABRICATION AND INSTALLATION. NO ALLOWANCE SHALL BE MADE FOR LACK OF SKILL
ON THE PART OF THE WORKMAN IN THE ACCEPTANCE AND/OR REJECTION OF
COMPLETED WORK.
13. MATERIALS AND EQUIPMENT SHALL BE NEW AND INSTALLED AS INDICATED ON THE
DRAWINGS AND/OR SPECIFICATIONS. THEY SHALL BE INSTALLED PLUMB, LEVEL AND
TRUE -TO -LINE WITH ADJACENT WORK. WHERE INSTALLATION METHODS ARE NOT
SPECIFICALLY COVERED BY THE DRAWINGS AND/OR SPECIFICATIONS, FIRST CLA55
TRADE PRACTICES AND MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS
SHALL GOVERN.
W. VERIFY EXACT CARRIERS WITH CARRIER MANUFACTURER.
15. OPENINGS REQUIRED FOR PLUMBING THROUGH FLOORS AND WALLS SHALL BE DONE
BY THE GENERAL CONTRACTOR, BUT THIS CONTRACTOR 15 RESPONSIBLE FOR
VERIFICATION OF EXACT LOCATION AND SIZE. ON PIPING RUNS THROUGH FOUNDATION,
POURED WALLS AND CEILINGS, PROVIDE PROPERLY SIZED SLEEVES AND EXACT
LOCATION TO THE GENERAL CONTRACTOR FOR HIS PLACEMENT. ALL HOLES THROUGH
WALLS AND CEILINGS EXPOSED TO FINISH AREAS SHALL HAVE PIPE ESCUTCHEONS
WITH APPROPRIATE FINISH. SEAL ALL SLEEVES WITH ETHAFOAM BACK-UP ROD AND
SILICONE SEALANT - USE '3M' uCP25 21412. FIRE RATED CAULKING FOR PENETRATIONS
THROUGH POURED WALLS AND CEILINGS.
16. HORIZONTAL COPPER WATER LINES BE SUPPORTED AT SIX (6) FOOT INTERVALS FOR
ONE (9 INCH AND SMALLER DIAMETER AND TEN (10) FOOT INTERVALS FOR ONE AND
ONE QUARTER (1 I/4) NCH AND LARGER. SUPPORTS SHALL BE COPPER MATERIAL OF
SUFFICIENT STRENGTH WHICH SHALL NOT ADVERSELY REACT WITH PIPING MATERIAL.
17. PROVIDE POLISHED CHROME SUPPLIES, STOPS AND 17 GAUGE CAST BRASS P-TRAP
WITH CLEANOUT AT THE PLUMBING FIXTURES.
18. CAREFULLY EXAMINE ALL ARCHITECTURAL. STRUCTURAL, PLUMBING, H.V.A.C. AND
ELECTRICAL DRAWINGS PERTAINING TO THE CONSTRUCTION, COOPERATE WITH OTHER
TRADES IN LOCATING DUCTWORK, PIPING, EQUIPMENT, ETC. IN ORDER TO AVOID CONFLICT
WITH OTHER TRADES' WORK. NO CLAIM FOR ADDITIONAL COST WILL BE ALLOWED FOR
RELOCATING EQUIPMENT, PIPING, DUCTWORK. ETC.. THAT INTERFERES WITH PROPER
INSTALLATION OF OTHER TRADES' WORK.
19. INSULATE ALL HANDICAP LAVATORY P-TRAP AND ANGLE VALVE ASSEMBLIES WITH
TRUEBRO, HANDI LAVGUARD INSULATION KIT, MODEL all (OR APPROVED EQUAL), WHITE
COLOR WITH 3-PIECE INTERLOCKING TRAP ASSEMBLY AND 2-PIECE INTERLOCKING
ANGLE VALVE ASSEMBLIES. FASTENERS SHALL BE NYLON -TYPE SUPPLIED WITH KIT.
20. MAIN OR BRANCH SOIL, WASTE AND VENT PIPES AND FITTINGS SHALL BE PVC SCHEDULE
40 OR 80 PRODUCED AND LABELED AS ASTMD-2665-75. D-1784-75 AND F-891 AND
AS FOLLOWS,
-MINIMUM PIPE SLOPE - 1/8 , 12
- MAXIMUM PIPE SLOPE - 1/4 s 12
A ANY INTERIOR OR ROOFTOP PLUMBING EQUIPMENT WEIGHING OVER 400 LBS. SHALL
HAVE SEISMIC RESTRAINTS BASED ON TESTED METHODS ACCEPTABLE TO
AUTHORITY HAVING JURISDICTION.
22. INSULATE ALL HOT AND COLD WATER PIPING WITH r FIBERGLASS INSULATION.
23. PAINT ALL EXTERIOR NATURAL GAS PIPING.
24. GENERAL CONTRACTOR TO PROVIDE FRAMING FOR MECHANICAL EQUIPMENT AS WELL
AS WALL, FLOOR AND ROOF PENETRATIONS.
25. PLUMBING CONTRACTOR TO VERIFY GAS PRESSURE AVAILABLE WITH LOCAL UTILITY
TO ENSURE PROPER FINAL GAS PIPE SIZING. PROVIDE ENGINEER WITH INFORMATION
PRIOR TO INSTALLATION.
26. WATER SUPPLY PIPES, FITTINGS AND MATERIALS SHALL BE TYPES K, L. AND M COPPER.
27. GAS PIPING, FITTINGS AND MATERIALS SHALL BE BLACK WROUGHT IRON PIPE.
28. LAVATORY FAUCETS TO BE EQUIPPED WITH ASSE 1070 OR 1017 AUTOMATIC SAFETY
WATER MIXING DEVICE
29. PROVIDE ISOLATION VALVES ON WATER SUPPLY PER IPC SECTION 890.1190-F
30. POTABLE WATER SYSTEMS SHALL BE PROTECTED BY AN 12PZ(REDUCED PRESSURE
ZONE) BACKFLOW PREVENTER INSTALLED ON THE DEMAND SIDE OF THE WATER METER.
Ill 890.1130.C)
11�����kl�lldlld�il�6`ii1�4�liGP
Subject to compliance with all regulations
of State and Local Codes
City of Cari
DATE: 07/31 /19
WASTE AND VENT PIPING ISOMETRIC
NOT TO SCALE
MARK
DESCRIPTION
MFR / PRODUCT
HC WC
ACCESSIBLE WATER CLOSET
GERBER 21-811 WHITE
OVAL BOWL E TANK
WC LAV
ACCESSIBLE DROP -IN LAV
GERBER 20" X IB" 12-654-00
NO 12-654-00 W/ DELTA 501-DST FAUCET
US
UTILITY SINK
NEW UTILITY SINK WITH LEGS
INST
THE
THIS
i
I GENERAL NOTE: I
ALL CONTRACTORS SHALL ENSURE COORDINATION OF EQUIPMENT AND
MATERIALS INSTALLATION WITH OTHER BUILDING COMPONENTS. ALL WORK
SHALL BE DONE IN ACCORDANCE WITH ALL APPLICABLE STATE, COUNTY
AND LOCAL BUILDING REGULATIONS AND CODES AS WELL AS INDUSTRY
STANDARD PRACTICE. THESE REQUIREMENTS ARE CONSIDERED A PART
OF THE PLANS AND SPECIFICATIONS AND SHALL PREVAIL SHOULD THEY
DIFFER FROM THE PLANS OR SPECIFICATIONS. PRIOR TO BID SUBMISSION
OR ANY WORK BENG PERFORMED, THE CONTRACTOR SHOULD DIRECT THE
ARCHITECT'S/ET*INEER'S ATTENTION TO ANY DISCREPANCY. SHOULD THE
SAD CONTRACTOR NOT SO NOTIFY THE ARCHITECT/ENGINEER, THE
CONTRACTOR SHALL FULLY COMPLY WITHOUT CLAIM FOR EXTRA COSTS.
WC COUNTER
DROP -IN LAV
PLUMBING PLAN
31V - T-9
CONSTRUCTION DOCUMENTS
DES7FIOY ALL PREVIOUS DOCUL(EdfB
I
ulllin
II oil U ro
z�
I11 I111
11 H r
II IIII II Z U) 70
II 11111 � < V
1j111 W Q Z
11111111 W Q 0
pllll Z p a
IIIIII II ( Z N
IIIIII II Z Q 00
1��11111 W Y J LJ
j1II11 C
M _ > O
1�11 1j z Q d
(� Z >
�IIIII II (n O l.J
IIIIIIII W N
05
a$
=ilig
� J
ggem
o
s a3keg
�8
Yam+
hr- m u;$
�aaz-nte�i�_�8
y��.Cgc cci
gss
ga
ore
I€�g��
REVISIONS
NO. DESCRIPTION
L
0
•LF
r ~
W
W
N
c()
J J
0
Z
v
m 2
Q
Ir
Q
W Q 0
Z
U U a
Q
2
z
N
U O o
W
2
O N0
W; 5 iq/d
to
FO :�'✓�
C'/at
No. 19441
WAIC G
i
W
fs0 01 AM�Gt?t'
07A21/9
ORA" B.
onTE
Q1B
07- 2-19
PROJECT NUMBER-1921
ORAwINc NUMBER
781