Loading...
HomeMy WebLinkAboutCE Lawrence 237 John St CarmelBuilding Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Property/Builder Information Building Name CE Lawrence 237 John St Owner's Name Property Address 237 John St City, St, Zip Carmel, IN Phone Number Builder's Name CE Lawrence Phone Number Email Address Plan/Model Name Community/Development Permit Date/Number Organization Information Organization Name ESI Address City, St, Zip Fountaintown, IN 46130 Phone Number Website Rating/RESNET Information Provider ID ____-___ Sample Set ID 00000000 Registry ID Rater's Name Rater's ID 1839760 Rater's Email Rating Date 2019-07-18 Rating Type Projected Rating Reason for Rating New Home Rating Number Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 2 of 11 General Design Characteristics General Design Characteristics House Type One Story Foundation Type Enclosed Crawl Space Conditioned Floor Area 1640.00 Number of Bedrooms:3 Conditioned Floor Area Over Garage:0.00 % Of Floor Area on First Level Box Length 0.00 ft Box Width 0.00 ft Box Height 0.00 ft Heated Basement First Level Mid Level Second Level Third Level Distribution of Cond Floor Area(%) 100.0 Characteristics of Each Floor Number of Corners 8 Percent Open to Floor Above 0.0 Nominal Flat Ceiling Height 8.0 Percent Vaulted Ceiling 0.0 Building Envelope Characteristics Building Envelope Characteristics Ceiling(Attic Above) Type R-40 Blown Attic Vaulted Ceiling Type None Above-Grade Wall Type R-15 Foundation Wall Type R-10 Cont Floor Type Uninsulated Door Type Fiberglass Slab Type None Average Slab Depth Below Grade Heated Basement/Crawl 0.00 First Level 0.00 Type of Infiltration Measurement Blower door test Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 3 of 11 Building Envelope Characteristics Infiltration Rate 6.00 ACH @ 50 Pascals Foundation Wall Library List Foundation Wall: R-10 Cont Type Solid concrete or stone Thickness(in)2.0 Studs None Interior Insulation Continuous R-Value 10.0 Frame Cavity R-Value 0.0 Cavity Insulation Grade 1 Ins top 0.0 ft from top of wall Ins Bottom 0.0 ft from bottom of wall Exterior Insulation R-Value 0.0 Ins top 0.0 ft from top of wall Ins bottom 0.0 ft below grade Note Frame Floor Library List Floor: Uninsulated Information From Quick Fill Screen Continous Insulation R-Value 0.0 Cavity Insulation R-Value 0.0 Cavity Insulation Thickness (in.)0.0 Cavity Insulation Grade 3 Joist Size (w x h, in)1.5 x 9.5 Joist Spacing (in oc)16.0 Framing Factor - (default)0.1300 Floor Covering CARPET Note Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 4 of 11 Above-Grade Wall Library List Above-Grade Wall: R-15 Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value)0.0 Frame Cavity Insulation (R-Value)15.0 Frame Cavity Insulation Thickness (in)3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in)1.5 x 3.5 Stud Spacing (in o.c.)16.0 Framing Factor - (default)0.2300 Gypsum Thickness (in)0.5 Note Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading AGWall 1 North 0.280 0.290 45.00 0.0 0.0 0.0 0.85 0.70 None None AGWall 1 South 0.280 0.290 24.00 0.0 0.0 0.0 0.85 0.70 None None AGWall 1 East 0.280 0.290 36.00 0.0 0.0 0.0 0.85 0.70 None None Door: Fiberglass R-Value of Opaque Area 11.5 Storm Door No Note Roof Library List Ceiling: R-40 Blown Attic Information From Quick Fill Screen Continous Insulation (R-Value)30.0 Cavity Insulation (R-Value)10.0 Cavity Insulation Thickness (in)3.5 Cavity Insulation Grade 1 Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 5 of 11 Roof Library List Gypsum Thickness (in)0.500 Bottom Chord/Rafter Size(w x h, in)1.5 x 3.5 Bottom Chord/Rafter Spacing (in o.c.)24.0 Framing Factor - (default)0.1100 Ceiling Type Attic Note Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 6 of 11 Mechanical Equipment Number of Mechanical Systems 3 Heating SetPoint(F)68.00 Heating Setback Thermostat Not Present Cooling SetPoint(F)78.00 Cooling Setup Thermostat Not Present Heat: 92AFUE Gas Furn 64k SystemType Fuel-fired air distribution Fuel Type Natural gas Rated Output Capacity (kBtuh)64.0 Seasonal Equipment Efficiency 92.0 AFUE Auxiliary Electric 591 Eae Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 Cool: 13SEER A/C 2.5 ton System Type Air conditioner Fuel Type Electric Rated Output Capacity (kBtuh)30.0 Seasonal Equipment Efficiency 13.0 SEER Sensible Heat Fraction (SHF)0.70 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 DHW: 50 gal. 0.54EF Gas Water Heater Type Conventional Fuel Type Natural gas Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 7 of 11 Mechanical Equipment Energy Factor 0.54 Recovery Efficiency 0.76 Water Tank Size (gallons)50 Extra Tank Insulation (R-Value)0.0 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 8 of 11 Duct Systems Name Conditioned Floor Area(sq ft)1640.0 # of Returns 2 Heating System 92AFUE Gas Furn 64k Cooling System 13SEER A/C 2.5 ton Supply Duct Surface Area(sq ft)442.8 Return Duct Surface Area(sq ft)164.0 Duct Leakage Qualitative Assessment Not Applicable Duct Leakage to Outside Supply+Return 131.00 CFM @ 25 Pascals Supply Only Not Applicable Return Only Not Applicable Total Duct Leakage 0.00 CFM @ 25 Pascals Duct Tightness Test Postconstruction Test Type Location Percent Location R-Value Supply Conditioned space 100.0 0.0 Return Attic, under insulation 100.0 6.0 Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 9 of 11 Lights and Appliances Rating/RESNET audit Ceiling Fan CFM / Watt 0.00 Refrigerator kWh/yr 691 Refrigerator Location Conditioned Range/Oven Fuel Type Natural gas Induction Range No Convection Oven No Dishwasher Energy Factor 0.46 Dishwasher kWh/yr 0 Place Setting Capacity 12 Clothes Dryer Fuel Type Electric Location Conditioned Moisture Sensing No Energy Factor 3.01 Gas Energy Factor 2.67 Clothes Washer Location Conditioned LER (kWh/yr)704 MEF 0.817 Capacity (CU.Ft)2.874 Electricity Rate 0.08 Gas Rate 0.58 Annual Gas Cost 23.00 Qualifying Light Fixtures Interior CFLs %100.0 Interior Fluorescent %0.0 Exterior Lights %0.0 Garage Lights %0.0 Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 10 of 11 Mandatory Requirements IECC Requirements Verified IECC 04 false Verified IECC 06 false Verified IECC 09 true Verified IECC 12 false Verified IECC 15 false Verified NY-ECCC 2010 false Verified IECC MI false Seek Certification For: None ENERGY STAR Version 3 Checklist Thermal Enclosure Checklist false HVAC System Quality Installation Contractor Checklist false HVAC System Quality Installation Rater Checklist false Water Management System Builder Checklist false ENERGY STAR Version 3 Appliances Exist Amount Refrigerators false 0 Ceiling Fans false 0 Exhaust Fans false 0 Dishwashers false 0 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grad:false Basement Floor Area 0.00 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption:false Indoor airPlus Verification Checklist false Building Summary Property 237 John St Carmel, IN Weather:Indianapolis, IN CE Lawrence 237 John St Untitled.blg Organization ESI Builder CE Lawrence REM/Rate - Residential Energy Analysis and Rating Software v15.1 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. HERS Projected Rating 2019-07-18 Rater ID:1839760 Page 11 of 11 DOE Zero Energy Ready Home Home Builder ID Number Mandatory Requirements Verified Fenestration false Verified Insulation false Verified Duct Location false Verified Appliance false Verified Lighting false Verified Fan Efficiency false Verified Water Efficiency false Verified EPA Indoor airPLUS false Verified Renewable Energy Ready Solar Electric false Optional Home Builder Commitments for Recognition Certified under the EPA WaterSense for New Homes Program No Certified under the IBHS fortified for Safer Living Program No Followed the DOE Zero Energy Ready Home Quality Management Guidelines No The buyer of this home signed a waiver giving DOE Zero Energy Ready Home access to utility bill data for one year. No HOME CERTIFIED TO MEET THE PROVISIONS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE This home built at 237 John St, Carmel, IN by CE Lawrence exceeds the minimum requirements for the 2009 International Energy Conservation Code The 2009 International Energy Conservation Code is a registered trademark of the International Code Council, Inc. ( “ICC”). No version of this software has been reviewed or approved by ICC or its affiliates. REM/Rate - Residential Energy Analysis and Rating Software v15.1 The organization below certifies that the proposed building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in compliance with Chapter 4 based on Climate Zone 5A and with all mandatory requirements. Building Features Ceiling Flat R-40.0 Duct NA Name Signature Sealed Attic:NA Duct Leakage to Outside:131.00 CFM @ 25 Pascals Organization ESI Date July 18, 2019 Vaulted Ceiling NA Total Duct Leakage:0.00 CFM @ 25 Pascals Above Grade Walls R-15.0 Infiltration:Htg: 6.00 Clg: 6.00 ACH50 Foundation Walls R-10.0 Window U-Value: 0.280, SHGC: 0.290 Exposed Floor R-0.0 Heating Fuel-fired air distribution, Natural gas, 92.0 AFUE. Slab None Cooling Air conditioner, Electric, 13.0 SEER. Water Heating Conventional, Natural gas, 0.54 EF, 50.0 Gal. Chris Schiewer