HomeMy WebLinkAboutA000.2ELEVATION EC2M
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3303 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.40 5.51 4.66 47.55 11 0
AT EAVE 6.61 5.51 5.14 52.45 0 74.00
TOTAL (MIN)11.01 11.01 9.80 100.00
3
HIGH -
RIDGE VENT 4.40 5.51 5.00 49.32 0 0 40.00
AT EAVE 6.61 5.51 5.14 50.68 0 74.00
TOTAL (MIN)11.01 11.01 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
1012
1012 5:12
8:12
3030 FIXED
1012 10121012
12:12
1"x8" TRIM
SHAKE SIDINGPER SPECS
1012
BKT 20X24X5\pxql;BRICK VENEER REF. PRODUCT SPECS.
1012 1012
1"x6" TRIM
10
121012 STANDING SEAM METAL ROOF - REF. PRODUCT SPECS
SINGLES PER - REF. PRODUCT SPECS.
\pxql;4" ROWLOCK SILL - REF. PRODUCT SPECS
\pxql;SHINGLES PER - REF. PRODUCT SPECS.
\pxql;SHAKE SIDING - REF. PRODUCT SPECS.
STANDING SEAM METAL ROOF - REF. PRODUCT SPECS
\pxql;BRICK VENEER - REF. PRODUCTS SPECS.
1012
8:12
8:12
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
1"x6" TRIM
TOP OF FOUNDATION
12:12 10121012
8:12
\A1;4'-6" A.F.F.
\A1;1'-1"O.H.
\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.
\A1;6"O.H.\A1;6"O.H.
\A1;30'-6{\H0.750000x;\S3#4;}"
\A1;6"O.H.\A1;6"O.H.
\A1;2'-3{\H0.750000x;\S3#8;}"\A1;9'-2" BAY SHED PIVOT POINT
\A1;6'-0"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;6"O.H.
\A1;8'-0{\H0.750000x;\S1#2;}" GARAGE SHED PIVOT POINT
\A1;1'-1"O.H.
ADDRESS SIGN
SCALE:FRONT ELEVATION1/4" = 1'-0"-
ADDRESS
BRICK WRAP T.O. FOUNDATIONT.O. FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
ROOF SHINGLES, PER SPEC
SCALE:REAR ELEVATION1/8" = 1'-0"-
TOP OF FIRST FLOOR
FIRST FLOOR PLATE
ROOF SHINGLES, \PPER SPEC
HORIZONTAL SIDING, \PPER SPEC
6" FASCIA BOARD, \PPER SPEC
WINDOW HDR. HGT.
TOP OF FOUNDATION
612
612
BRICK WRAP
\A1;1'-1"O.H.\A1;1'-1"O.H.
\A1;7"O.H.
\A1;2'-3{\H0.750000x;\S3#8;}"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;1'-1"O.H.
\A1;4'-0"
SCALE:LEFT ELEVATION1/8" = 1'-0"-
\A1;16'-0"
\A1;6'-0"
\A1;12'-0"
\A1;1'-0"\PTYP.\A1;8'-1{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#2;}"
\A1;6'-7{\H0.750000x;\S3#4;}"
\A1;6'-0"
PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION
SCALE:ROOF PLAN1/8" = 1'-0"-
6:12
8:12
10:12
8:12
8:12 10:1210:1210:1210:12
10:12
10:1210:12 6:1210:1210:12
8:12
ROOF AREA"A"3303 SQ. FT.
6:12 6:12
128 612612
BRICK WRAP
\A1;8'-10{\H0.750000x;\S5#8;}"\A1;HDR. HGT. @ 4010
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
SCALE :1/4" = 1'-0"INTERIOR PORCH ELEVATION EC2M
SHAKE SIDINGPER SPECSSHAKE SIDINGPER SPECS 1"x6" TRIM SHAKE SIDINGPER SPECS 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
SUZETTE SCHUETTE06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 13
06/28/2019
PLOTTED: July 9, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-EC2M.DWG
A3
EC2M-2GS.1Elevation EC2M - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule07/26/19
Mike Sheeks