Loading...
HomeMy WebLinkAboutA000.2ELEVATION EC2M ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3303 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.40 5.51 4.66 47.55 11 0 AT EAVE 6.61 5.51 5.14 52.45 0 74.00 TOTAL (MIN)11.01 11.01 9.80 100.00 3 HIGH - RIDGE VENT 4.40 5.51 5.00 49.32 0 0 40.00 AT EAVE 6.61 5.51 5.14 50.68 0 74.00 TOTAL (MIN)11.01 11.01 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 1012 1012 5:12 8:12 3030 FIXED 1012 10121012 12:12 1"x8" TRIM SHAKE SIDINGPER SPECS 1012 BKT 20X24X5\pxql;BRICK VENEER REF. PRODUCT SPECS. 1012 1012 1"x6" TRIM 10 121012 STANDING SEAM METAL ROOF - REF. PRODUCT SPECS SINGLES PER - REF. PRODUCT SPECS. \pxql;4" ROWLOCK SILL - REF. PRODUCT SPECS \pxql;SHINGLES PER - REF. PRODUCT SPECS. \pxql;SHAKE SIDING - REF. PRODUCT SPECS. STANDING SEAM METAL ROOF - REF. PRODUCT SPECS \pxql;BRICK VENEER - REF. PRODUCTS SPECS. 1012 8:12 8:12 WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT 1"x6" TRIM TOP OF FOUNDATION 12:12 10121012 8:12 \A1;4'-6" A.F.F. \A1;1'-1"O.H. \A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H.\A1;1'-1"O.H. \A1;6"O.H.\A1;6"O.H. \A1;30'-6{\H0.750000x;\S3#4;}" \A1;6"O.H.\A1;6"O.H. \A1;2'-3{\H0.750000x;\S3#8;}"\A1;9'-2" BAY SHED PIVOT POINT \A1;6'-0" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;6"O.H. \A1;8'-0{\H0.750000x;\S1#2;}" GARAGE SHED PIVOT POINT \A1;1'-1"O.H. ADDRESS SIGN SCALE:FRONT ELEVATION1/4" = 1'-0"- ADDRESS BRICK WRAP T.O. FOUNDATIONT.O. FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. ROOF SHINGLES, PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- TOP OF FIRST FLOOR FIRST FLOOR PLATE ROOF SHINGLES, \PPER SPEC HORIZONTAL SIDING, \PPER SPEC 6" FASCIA BOARD, \PPER SPEC WINDOW HDR. HGT. TOP OF FOUNDATION 612 612 BRICK WRAP \A1;1'-1"O.H.\A1;1'-1"O.H. \A1;7"O.H. \A1;2'-3{\H0.750000x;\S3#8;}" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;1'-1"O.H. \A1;4'-0" SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;16'-0" \A1;6'-0" \A1;12'-0" \A1;1'-0"\PTYP.\A1;8'-1{\H0.750000x;\S1#2;}"\A1;8'-1{\H0.750000x;\S1#2;}" \A1;6'-7{\H0.750000x;\S3#4;}" \A1;6'-0" PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION SCALE:ROOF PLAN1/8" = 1'-0"- 6:12 8:12 10:12 8:12 8:12 10:1210:1210:1210:12 10:12 10:1210:12 6:1210:1210:12 8:12 ROOF AREA"A"3303 SQ. FT. 6:12 6:12 128 612612 BRICK WRAP \A1;8'-10{\H0.750000x;\S5#8;}"\A1;HDR. HGT. @ 4010 SCALE:RIGHT ELEVATION1/8" = 1'-0"- SCALE :1/4" = 1'-0"INTERIOR PORCH ELEVATION EC2M SHAKE SIDINGPER SPECSSHAKE SIDINGPER SPECS 1"x6" TRIM SHAKE SIDINGPER SPECS 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 SUZETTE SCHUETTE06/07/2013 GARAGE RIGHT Croix 1993.301 LOT 13 06/28/2019 PLOTTED: July 9, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-EC2M.DWG A3 EC2M-2GS.1Elevation EC2M - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule07/26/19 Mike Sheeks