HomeMy WebLinkAboutA000.3\A1;1'-1"
1012
1012
3:12
\A1;4'-6" A.F.F.
\A1;3'-2" TYP.
SHINGLES PERSUB. SPECS.
STONE PER SPECS
4" SILL
9" CROSSHEAD
SIDING PER SPECS
SHINGLES PERSUB. SPECS.
9" CROSSHEAD (TYP.)
SIDING PER SPECS16x36 LOUV. VENT
4" TRIM SURROUND ON DOOR 10" SQ. HALF COLUMN(SEE PORCH DETAIL)
4" TRIM SILL16x36 LOUV. VENT
SHAKE SIDING PER SPECS9" CROSSHEAD OVER DOOR
4" TRIM BOARD
\A1;3'-2" TYP.
\A1;4'-0"
DORMERS TO BE CENTERED WITH ARCHES BELOW.\PSEE DETAIL W/ET.3
\A1;EQUAL\A1;EQUAL 101210
6" CORNER BOARD (TYP.)4" TRIM
28302830 SHINGLES PER SUB SPECS.FIXEDFIXED
\A1;14'-4"\A1;3'-4"\A1;6'-8"\A1;3'-4"
12
SHINGLES PER SUB SPECS.
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
WINDOW HEIGHT
1st FLR LINE
PLATE HEIGHT
10" SQ. COLUMN(SEE PORCH DETAIL)
SCALE:FRONT ELEVATION1/4" = 1'-0"-
BRICK WRAP T.O. FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP.
ROOF SHINGLES, PER SPEC
SCALE:REAR ELEVATION1/8" = 1'-0"-
WINDOW HEIGHT
1st FLR LINE
CEILING HEIGHT\A1;1'-1"
SIDING PER SPECS
\A1;2'-0"
\A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"
\A1;1'-1"
BRICK WRAP
612 612
SCALE:LEFT ELEVATION1/8" = 1'-0"-
\A1;1'-0"\PTYP.
\A1;8'-0"
\A1;24'-0"\A1;6'-0"
SCALE:ROOF PLAN1/8" = 1'-0"-
ROOF AREA"A"3330 SQ. FT.
10:1210:12
10:1210:12
3:12
10:1210:12
6:12
6:12
10:1210:12
ELEVATION CR2H
ATTIC VENT SCHEDULE
VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE
** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS
* SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION
ROOF AREA "A"SQ FTG 3330 AT / NEAR RIDGE AT / NEAR EAVE
VENT TYPE
SQ. FT.
REQUIRED
RANGE
SQ. FT.
SUPPLIED
PERCENT
OF TOTAL
SUPPLIED
POT LARGE
(SQ. IN. EACH)
POT SMALL
(SQ. IN. EACH)
RIDGE VENT
(SQ. IN. PER LF)
EAVE VENT
(SQ. IN. EACH)
CONT. VENT
(SQ. IN. PER LF)
61.00 40.00 18.00 28.00 10.00
HIGH - POT
VENTS ONLY 4.44 5.55 5.08 49.73 12 0
AT EAVE 6.66 5.55 5.14 50.27 0 74.00
TOTAL (MIN)11.10 11.10 10.22 100.00
3
HIGH -
RIDGE VENT 4.44 5.55 5.00 49.32 0 0 40.00
AT EAVE 6.66 5.55 5.14 50.68 0 74.00
TOTAL (MIN)11.10 11.10 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE
BRICK WRAP
\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. @ 4020
612 612
SCALE:RIGHT ELEVATION1/8" = 1'-0"-
SCALE 1/4" = 1'-0"PORCH ELEVATIONS
LEFT PORCH FRONT PORCH RIGHT PORCH2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP)
\A1;3'-8{\H0.750000x;\S1#2;}"
\A1;2'-5"
\A1;4"\A1;4"
\A1;3'-4"
DORMER DETAIL
9" CROSSHEADTRIM BOARD AROUND WINDOW 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office...........................
PLAN NAME
SHEET
PRODUCTION MANAGER
DATE / DESCRIPTION
NPC PLAN NUMBERLAWSON PLAN ID
GARAGE HANDING
REV #
NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS
INITIAL RELEASE DATE:CURRENT RELEASE DATE:
(c) Copyright Pulte Home Corporation - 2019
SUZETTE SCHUETTE06/07/2013
GARAGE RIGHT
Croix
1993.301
LOT 05
06/26/2019
PLOTTED: June 26, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-CR2H.DWG
A3
CR2H-2GS.1Crafstman 2H - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule08/01/19
William Hohlt