Loading...
HomeMy WebLinkAboutA000.3\A1;1'-1" 1012 1012 3:12 \A1;4'-6" A.F.F. \A1;3'-2" TYP. SHINGLES PERSUB. SPECS. STONE PER SPECS 4" SILL 9" CROSSHEAD SIDING PER SPECS SHINGLES PERSUB. SPECS. 9" CROSSHEAD (TYP.) SIDING PER SPECS16x36 LOUV. VENT 4" TRIM SURROUND ON DOOR 10" SQ. HALF COLUMN(SEE PORCH DETAIL) 4" TRIM SILL16x36 LOUV. VENT SHAKE SIDING PER SPECS9" CROSSHEAD OVER DOOR 4" TRIM BOARD \A1;3'-2" TYP. \A1;4'-0" DORMERS TO BE CENTERED WITH ARCHES BELOW.\PSEE DETAIL W/ET.3 \A1;EQUAL\A1;EQUAL 101210 6" CORNER BOARD (TYP.)4" TRIM 28302830 SHINGLES PER SUB SPECS.FIXEDFIXED \A1;14'-4"\A1;3'-4"\A1;6'-8"\A1;3'-4" 12 SHINGLES PER SUB SPECS. \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" WINDOW HEIGHT 1st FLR LINE PLATE HEIGHT 10" SQ. COLUMN(SEE PORCH DETAIL) SCALE:FRONT ELEVATION1/4" = 1'-0"- BRICK WRAP T.O. FLOOR \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. TYP. ROOF SHINGLES, PER SPEC SCALE:REAR ELEVATION1/8" = 1'-0"- WINDOW HEIGHT 1st FLR LINE CEILING HEIGHT\A1;1'-1" SIDING PER SPECS \A1;2'-0" \A1;9'-1{\H0.750000x;\S1#8;}"\A1;8'-2{\H0.750000x;\S7#8;}" \A1;1'-1" BRICK WRAP 612 612 SCALE:LEFT ELEVATION1/8" = 1'-0"- \A1;1'-0"\PTYP. \A1;8'-0" \A1;24'-0"\A1;6'-0" SCALE:ROOF PLAN1/8" = 1'-0"- ROOF AREA"A"3330 SQ. FT. 10:1210:12 10:1210:12 3:12 10:1210:12 6:12 6:12 10:1210:12 ELEVATION CR2H ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 3330 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 4.44 5.55 5.08 49.73 12 0 AT EAVE 6.66 5.55 5.14 50.27 0 74.00 TOTAL (MIN)11.10 11.10 10.22 100.00 3 HIGH - RIDGE VENT 4.44 5.55 5.00 49.32 0 0 40.00 AT EAVE 6.66 5.55 5.14 50.68 0 74.00 TOTAL (MIN)11.10 11.10 10.14 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE BRICK WRAP \A1;8'-2{\H0.750000x;\S7#8;}"\A1;HDR. HGT. @ 4020 612 612 SCALE:RIGHT ELEVATION1/8" = 1'-0"- SCALE 1/4" = 1'-0"PORCH ELEVATIONS LEFT PORCH FRONT PORCH RIGHT PORCH2" CORNER BOARD (TYP)SIDING PER COMM. SPECS (TYP) \A1;3'-8{\H0.750000x;\S1#2;}" \A1;2'-5" \A1;4"\A1;4" \A1;3'-4" DORMER DETAIL 9" CROSSHEADTRIM BOARD AROUND WINDOW 1900 Golf Road, Suite 300Schaumburg, Illinois 60173Midwest Zone Office........................... PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2019 SUZETTE SCHUETTE06/07/2013 GARAGE RIGHT Croix 1993.301 LOT 05 06/26/2019 PLOTTED: June 26, 2019 / Annie Lee / 1993-CROIX-CZ-BAS2-EL-CR2H.DWG A3 CR2H-2GS.1Crafstman 2H - Slab2 Car Front EntryFront, Side and Rear Elevations, Roof Plan and Ventilation Schedule08/01/19 William Hohlt