Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SHW 005 - Plot Plan REV 7-1-19
"BASE HOUSE STANDARD FEATURES" MODEL: CROIX `' SLAB FOUNDATION 2 CAR FRONT ENTRY GARAGE BRICK WRAP +� "SELECTED FEATURES" ELEV CR2H - RIGHT HAND ✓ GOLF CART ST RAGE .� SUNROOM •/ 13.6'X12' CONCRETE PATIO ✓ NOTE: Minimum Front Yard - 20' Minimum Side Yard - 5'110' AGG Minimum Rear Yard - 25' XX.X = Proposed Grade = Drainage Flow = Overflow Route SW 403 SAN MH TC=917.99 N ote: SW 402 SAN MH TC=918.90 The lowest elevation to have gravity sanitary sewer service must be more than one (1) foot above the lowest top of casting elevation of either the first upstream or downstream manhole on the main line sewer to which the connection is made. Note: Manholes must remain accessible and at grade at all times. ' N ote: LOT #5 ±11,821 SF PAD 919.6 PER PLAN MFFE 920.2 PER PLAN MFPG 920.2 PER PLAN MLAG 919.7 PER PLAN .. Ivl Com•. .`rjST Na. S0557 STATE OF 4N0 SUlp,,�oc Contractor should verify site specific information depicted hereon with the approved construction plans for this development in regards to sidewalk and handicap ramp placement, widths, and construction. Contractor should verify site specific information in regards to erosion control placement and materials. Also, Contractor should reference Architectural plans for foundation orientation and dimensions. The contractor/owner should verify existing conditions prior to construction. Any varying field conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, Corp.; failure to do so would result in the contractor/owners assumption of liability. k Gar. FFE = 920.2 1 st Fir FFE = 921.0 TOW = 921.0 Bsmt FFE = NIA Drive Slope = ±8.0% I -FO.OV i rLiI , 9 � � r F1fnHazard Note: TLotNNumber 5 lies within Flood Hazard Zone "X" per the scaled location on the Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057CO205G, dated November 19, 2014). * Conc Flatwork Sq. Ft = ±952 Public Walk Sq Ft = ±313 Sod Sq Yds = ±195 Seeding Sq Ft = ±6,C16 * (Drive, Apron, 3' Walk, Patio, Stoops) (PORCH NOT INCLUDED) 0 O b0 'Mz m y Note: Unless otherwise stated hereon, no information pertaining to but not limited to, fluctuating water tables elevations, soil types, and conditions within the building areas of this development have been provided andlor referenced on said documents. With the excavation of the proposed structure foundations, certain care and observations should he made in regard to such conditions as soil types and fluctuating water tables. During the excavation process should any unsuitable sails or ground water he witnessed, the builder shall be immediately notified for further examination and consultation. At the builders discretion, additional construction techniques may be necessary to alleviate future problems. Note: This document has been prepared for the benefit of the parties indicated hereon, for the express use of obtaining a residential building permit. This document has been prepared and based upon the construction documents, record drawings, and additional information prepared for this development by others. This document is not based upon a field survey and Coor Consulting does not warrant the accuracy or completeness of this information. SHADOW WOOD P.G. 5, SLIDE 730 00r. INSTR # 2017048049 ©LM0U dig Nod C� O F LOT #5 303 WEST MAIN STREET KNIGHTSTOWN. INDIANA ,/ (888) 593-2667 (765) 345-5943 FAX#: (765) 345-5692 14485 CARLOW RUN DATE: 06/25/19 JOB #2016-080.005 REVISIONS:1 CARMEL, IN 46074 PLOT PLAN Prepared For: *PulteGroup Pulte Homes of Indiana