HomeMy WebLinkAboutP1.0 Soil, Waste, And Vent Plumbing Plan (2)F,, 3. 4. 5. 6. 7. 8 m 10. IT. PLUMBING GENERAL NOTES THE EQUIPMENT ROUGH -IN ITEMS AND THEIR DIMENSIONED LOCATIONS FOR ALL CONNECTIONS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. IN SOME INSTANCES THE OWNER OR SUPPLIER MAY MAKE SUBSTITUTIONS OR THE EQUIPMENT ITEMS MAY VARY FROM WHAT IS SHOWN. THEREFORE, THESE ITEMS AND DIMENSIONS SHALL BE VERIFIED WITH THE EQUIPMENT SUPPLIER, OWNER AND/OR EQUIPMENT ROUGH -IN DRAWINGS. THE ARCHITECT/ENGINEER SHALL BE IMMEDIATELY NOTED, PRIOR TO CONSTRUCTION, OF ANY DEMATIONS FROM WHAT IS SHOWN OR IMPLIED ON THESE DRAWINGS. FAILURE OF THE APPROPRIATE CONTRACTOR TO VERIFY ROUGH -INS OR THEIR LOCATIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION AND/OR ADDITIONAL ROUGH -INS DIRECTLY UPON THE CONTRACTOR. CONTRACTOR SHALL SUPPLY TO THE ARCHITECT SIX COPIES OF SHOP DRAWINGS FOR APPROVAL SO THE QUALITY OF INTENDED MATERIALS OR EQUIPMENT CAN BE RENEWED BEFORE INSTALLATION. THERE WILL BE NO DRAW UNTIL SHOP DRAWINGS HAVE BEEN SUBMITTED AND RENEWED BY ARCHITECT/ENGINEER. DO NOT SCALE THIS DRAWING. REFER TO ARCHITECTURAL FLOOR PLANS FOR BUILDING DIMENSIONS. THE SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT THE CONTRACTOR HAS FAMILIARIZED HIMSELF WITH THE PLANS AND BUILDING SITE. CLAIMS MADE SUBSEQUENT TO THE PROPOSAL FOR MATERIALS AND LABOR BECAUSE OF DIFFICULTIES ENCOUNTERED WALL NOT BE RECOGNIZED, IF THEY COULD HAVE BEEN FORESEEN HAD PROPER EXAMINATION BEEN MADE. VERIFY SERVICE POINTS AND METERING LOCATIONS FOR PROJECT WITH LOCAL UTILITIES AND/OR LANDLORD (DOMESTIC WATER, SANITARY SEWER, GAS, ETC.) THE CONTRACTOR SHALL COOPERATE FULLY AMONG THE TRADES. ALL ROOF PENETRATIONS FOR ROOF DRAINS AND PLUMBING/GAS/ REFRIGERANT PIPING SHALL BE MADE IN ACCORDANCE WTH ROOF SYSTEM MANUFACTURER'S GUIDELINES COORDINATE NTH ARCHITECTURAL DETAILS AND/OR LANDLORD FOR ROOF SYSTEM USED. PLUMBING CONTRACTOR SHALL VERIFY WITH THE LOCAL HEALTH DEPARTMENT AND/OR WATER COMPANY AS TO THE METER AND VALUING ARRANGEMENT OF THE DOMESTIC WATER SERVICE LINE WHICH ENTERS THE BUILDING. SHOULD A BACKFLOW PREVENTER ASSEMBLY AND/OR PRESSURE REDUCING VALVE ASSEMBLY BE REQUIRED, THE PLUMBER SHALL FURNISH AND INSTALL SAME PER LOCAL AND STATE REQUIREMENTS. THE BACKROW ASSEMBLY SHALL BE A -WATTS' SERIES /909 OR APPROVED EQUAL MEETING ASSE STANDARDS 1013. 1015 AND 1020. IF BACKFLOW PREVENTER IS INSTALLED, PROVIDE PROPERLY SIZED THERMAL EXPANSION TANK IN SUPPLY PIPING OF WATER HEATER. IF WATER PRESSURE IS 65 PSI OR GREATER, A PRESSURE REDUCING VALVE ASSEMBLY SHALL BE A 'WATTS° SERIES g2SAUB-Z3 OR APPROVED EQUAL SET AT 50 LBS, DELIVERY PRESSURE UNLESS OTHERWISE NOTED. THE WATER PIPING SYSTEM SHALL BE FLUSHED AND STERILIZED IN ACCORDANCE NTH LOCAL REGULATIONS. THE POTABLE WATER SUPPLY SHALL BE PROTECTED AGAINST BACKROW AND SIPHONAGE BOTH NATURAL AND INDUCED. ALL EQUIPMENT CONNECTED TO THE POTABLE WATER SYSTEM BEING CAPABLE OF POLLUTING OR CONTAMINATING THE POTABLE WATER DISTRIBUTION SYSTEM OR ANY PART THEREOF BY MEANS OF A REVERSAL OF FLOW, PRESSURE DROP, PRESSURE LOSS, INDUCED VACUUM OR BY INJECTION BECAUSE OF ANY PRIMARY OR AUXNARY PUMPING SYSTEM CONNECTED THERETO MUST BE ISOLATED AND CONTAINED BY MEANS OF APPROVED BACKFLOW DEVICES, CHECK VALVES, AIR GAPS OR VACUUM BREAKERS. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL THESE DEUCES PER LOCAL CODE REQUIREMENTS. THE HOT AND COLD WATER SUPPLY BRANCHES FOR ALL EQUIPMENT HAVING QUICK CLOSING VALVES OF ANY TYPE SHALL HAVE WATER HAMMER ARRESTORS INSTALLED AT THE HIGH POINT ON THE END OF EACH BRANCH. 12. FURNISH AND INSTALL SHUTOFF OR BALL VALVE AND DIELECTRIC UNION ON ALL EQUIPMENT HOT AND COLD WATER LINES. PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO EQUIPMENT. COORDINATE NTH EQUIPMENT SUPPLER FOR EXACT REQUIREMENTS. 13. FURNISH & INSTALL 1" (MIN.) FIBERGLASS INSULATION NTH ALL -SERVICE JACKET ON ALL HOT, COLD, RECIRCULATING WATER UNES ABOVE SLAB AND ALL CONDENSATE FROM MECHANICAL UNITS. 14. WATER PIPE AND FITTINGS SHALL BE COPPER OR BRASS PER CODE. ABOVE GROUND SHALL BE TYPE L RIGID COPPER. BELOW GROUND SHALL BE TYPE K SOFT COPPER NTH NO JOINTS PERMITTED BELOW GROUND. ALL JOINTS SHALL BE MADE NTH 95-5 SOLDER OR EQUAL. 15. BARRIER FREE LAVATORY P-TRAP AND ANGLE STOP ASSEMBLIES SHALL BE INSULATED NTH TRAP WRAP PROTECTIVE KIT 50OR BY BROCAR (1-800-827-1207) OR EQUAL. ABRASION RESISTANT EXTERIOR COVER SHALL BE SMOOTH AND HAVE 1/8" MIN. WALL OVER CUSHIONED FOAM INSERT. FASTENERS SHALL REMAIN SUBSTANTIALLY OUT OF SIGHT. 16. VERIFY MOUNTING HEIGHTS OF ALL BARRIER FREE FIXTURES NTH ARCH. PLANS RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City GF Carmel �VT�S2t�B*141WML DATE: \ 08/01/19 17. INSTALL 1" FIBERGLASS INSULATION WALL -SERVICE JACKET ON ALL ROOF LEADERS ABOVE CEILING. 18. FURNISH AND INSTALL CONDENSATE LINES FROM ANY MECHANICAL EQUIPMENT AS REQUIRED. WHERE LOCAL JURIDICATION REQUIRES ANY CONDENSATE LINE TO RUN ABOVE THE CEILING OR IN A LOCATION WHERE THE PIPES SWEATING COULD CAUSE DAMAGE, SHALL BE INSULATED. RUN FULL SIZE TO DRAIN OR AS INDICATED ON PLANS. TURN DOWN WITH REQUIRED AIR GAP. 19. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL COPPER INDIRECT WASTE PIPING REQUIRED FROM EQUIPMENT TO FLOOR DRAINS, OPEN RECEPTACLES, OR FLOOR SINKS. PIPING SHALL COMPLY WITH STATE AND LOCAL CODES. COORDINATE WITH ALL EQUIPMENT SUPPLIERS AND SIZE AS REQUIRED BY PIECE OF EQUIPMENT SERVED. HOLD PIPING TIGHT TO WALL WHERE APPLICABLE PROPERLY SECURE AS REQUIRED. COORDINATE WITH CASEWORK SUPPLIER FOR MAXIMUM CLEARANCE UNDER CABINETS. 20, ALL EXPOSED GAS PIPING SHALL BE PAINTED TO MATCH ADJACENT WALL. 21. ALL VENT PIPE TO BE COMPATIBLE WITH STRUCTURE, MECHANICAL. EQUIPMENT AND DUCTWORK, ELECTRICAL EQUIPMENT AND LIGHTING. 22. THE NATURAL GAS TO THE EQUIPMENT SHALL BE LOW PRESSURE. THE REGULATOR OUTLET PRESSURE SHALL BE 7" WATER COLUMN. IF THE GAS COMPANY IS UNABLE TO PROVIDE THIS PRESSURE, IMMEDIATELY CONTACT THE A/E OR OWNER FOR INSTRUCTIONS. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL, U.O.N. 23. PROVIDE CHROME PLATED ESCUTCHEONS AT ALL WALL PENETRATIONS. 24, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 OR 80, TYPE 1, GRADE 1, POLYVINYL CHLORIDE COMPOUNDS AS DEFINED AND DESCRIBED IN THESE SPECIFICATIONS FOR RIGID PVC. CONTRACTOR MAY USE CAST IRON. 25. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 OR 80, TYPE 1, GRADE 1, POLYVINYL CHLORIDE COMPOUNDS AS DEFINED AND DESCRIBED IN THESE SPECIFICATIONS FOR RIGID PVC (ASTM DESIGNATION: D 2665, D 2949, F891 OR SCHEDULE 40 OR 30 ACRYLONITRILE-BUTADIENE-STYRENE COMPOUND AS DEFINED AND DESCRIBED IN STANDARD SPECIFICATIONS FOR ABS (ASTM DESIGNATION: D2661 OR F 628). IF PSIS NOT PERMITTED BY CODE PERMI��BY CODE CONTRACTOR TO USE CAST IRON IN UEU OF PVC. INSTALL PVC OR ABS PIPING PER CODE. PLUMBING CONTRACTOR SHALL INSTALL 4" SOIL, WASTE AND GREASE WASTE PIPING NTH A MINIMUM SLOPE OF 1/8° PER FOOT OR AS REQUIRED BY CODE. 26, FOR FLOOR TILES: HOLD TOP OF FLOOR DRAINS RUSH WITH FINISHED FLOOR. SEE ARCH. SHEETS FOR FLOOR SLOPES AROUND DRAINS. (IF REQ'D) FOR ALTRO SHEET VINYL INSTALLATIONS: FOLLOW ALL DETAILS FOR SURFACE MEMBRANE CLAMPING FIXTURES. 27. ALL NEW V.T.R'S SHALL BE EXTENDED TO A MINIMUM OF 12" ABOVE PARAPET HEIGHT AND MAINTAINED 10'-0" MINIMUM FROM ALL OUTSIDE AIR INTAKES. 28. MATERIALS, EQUIPMENT, ASSEMBUES AND SYSTEMS SHALL MEET ALL PERTINENT REQUIREMENTS OF NATIONALLY RECOGNIZED TESTING ORGANIZATION SUCH AS THE UL, ASTM, ASSE, AWWA, AGA AND Ni AS WELL AS THE MOST CURRENT VERSION OF THE STATE CODE AND LOCAL AMENDMENTS. 29. ALL INSTALLED SYSTEMS, DEVICES AND RELATED ITEMS SHALL BE TESTED IN PLACE ON SITE PER LOCAL CODE REQUIREMENTS. REPLACE ANY AND ALL CONTRACTOR SUPPLIED DEFECTIVE DEVICES, ITEMS OR SYSTEMS AT CONTRACTOR'S OWN EXPENSE BEFORE COMPLETION OF PROJECT. 30. WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACT DOCUMENTS THAT DO NOT CHANGE THE SCOPE OR NATURE OF THE WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCH CHANGES WTHOUT ADDITIONAL COST TO THE OWNER. NO OTHER CHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE OWNER. 31. ALL EQUIPMENT, FIXTURES AND MATERIALS SHALL BE NEW AND UNUSED, AND INSTALLED IN STRICT CONFORMANCE TO MANUFACTURER'S RECOMMENDATIONS (U.Oi PROVIDE COMPLETE NTH ALL TRIM, STOPS, HANGERS, CARRIERS, SUPPORTS, ETC. INCLUDING PROVISIONS FOR BARRIER FREE USE, IF REQUIRED. WHERE FIXTURES ARE ACCESSIBLE, THEY MUST COMPLY NTH ALL FEDERAL A.D.A. REGULATIONS. 32. CONTRACTOR SHALL GUARANTEE ALL WORK FOR WHICH MATERIALS ARE FURNISHED, FABRICATED OR FIELD ERECTED, ALL FACTORY ASSEMBLED EQUIPMENT FOR WHICH NO SPECIFIC MANUFACTURER'S GUARANTEE IS FURNISHED AND ALL WORK IN CONNECTION NTH THE INSTALLATION OF MANUFACTURER'S GUARANTEED EQUIPMENT. THIS CONTRACTOR'S GUARANTEE SHALL EXIST FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL OWNER ACCEPTANCE OF THE WORK AND SHALL APPLY TO ALL DEFECTS IN MATERIALS AND/OR WORKMANSHIP OF ANY KIND. 33. BIDDERS SHALL BE LICENSED CONTRACTORS IN ACCORDANCE NTH LOCAL AND AND STATE LAWS. 34. ALL PERMITS AND FEES REQUIRED FOR THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR AND INCLUDED IN THE BID PRICE. 35. ALL PLUMBING FIXTURES AND PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE NTH THE LATEST EDITION OF STATE AND/OR LOCAL CODES. COOPERATE AS REQUIRED WTH ALL AUTHORITIES HAVING JURISDICTION TO INSURE THAT PROPER MATERIALS AND WORKMANSHIP ARE USED. REQUIREMENTS OF STATE AND LOCAL CODES AND AUTHORITIES TAKE PRECEDENCE OVER ANY INFORMATION WHICH IS INDICATED OR IMPLIED ON THESE DRAWINGS 36. THIS SYMBOL 000 INDICATES ITEM TO BE FURNISHED BY OWNER OR KITCHEN EQUIPMENT SUPP ER. COORDINATE INSTALLATION AND FINAL CONNECTION REQUIREMENTS NTH SUPPLIER. FIELD VERIFY SIZES AND LOCATIONS OF ALL SUPPLIER. FIELD VERIFY SIZES AND LOCATIONS OF ALL WATER, WASTE, INDIRECT WASTE, GAS AND/OR ELECTRICAL CONNECTIONS PRIOR TO INSTALLATION (TYPICAL ALL PLUMBING EQUIPMENT). 37. SEE PLUMBING ROUGH -IN DRAWINGS PROVIDED BY KITCHEN EQUIPMENT SUPPLIER FOR MORE INFORMATION. 38. ALL INDIRECT WASTE, WASTE PIPING OR FIXTURE WHICH RECEIVES THE DISCHARGE FROM A DISHWASHER, STEAMER OR SIMILAR PIECE OF EQUIPMENT WHICH PRODUCES SIMILAR PIECE OF EQUIPMENT WHICH PRODUCES WATER AT A TEMPERATURE HIGHER THAN 125F SHALL BE DWV COPPER OR CAST IRON A MINIMUM OF 10'-0" DOWNSTREAM FROM THE OUTLET PRODUCING SUCH DISCHARGE. COORDINATE WITH KES. 39. ALL INDIRECT WASTE PIPING FROM EQUIPMENT TO ABOVE FLOOR RECEPTOR SHALL BE 1" (MIN.) COPPER UNLESS LARGER SIZE IS INDICATED BY EQUIPMENT OPENING OR KES. SOIL, WASTE & VENT PLUMBING PLAN SOMM V4• a T-1 PLUMBING LEGEND ALL SYMBOLS SHOWN IN THIS LEGEND MAY NOT APPEAR IN THESE DOCUMENTS. GW GREASE WASTE PIPING SAN - SOIL AND WASTE PIPING VENT PIPING COLD WATER PIPING (CW) HOT WATER PIPING (HW) RECIRCULATING WATER PIPING T TEMPERED WATER PIPING F FILTERED WATER PIPING UNION GATE OR STOP VALVE H CHECK VALVE OR BACKFLOW PREVENTER 5 BALL VALVE JI" VTR QO VENT-THRU-ROOF L13 MANUAL GAS SHUT OFF VALVE ® FLOOR DRAIN ® FLOOR SINK TRENCH DRAIN p� 0 CLEANOUT AFT ABOVE FINISHED FLOOR OCROCRED FIXTURE/EQUIPMENT DESIGNATIONS DFU VALUES MARK DESCRIPTION CITY I DFU TOTAL E K FLOOR DRAIN 6 0 0 F1 FLOOR SINK (3" TRAP) 7 5 25 F2 FLOOR SINK (4" TRAP) 1 6 18 133 303 HAND SINK - KITCHEN AREAS 2 2 4 801 J UTILITY MOP SINK 1 5 5 A WATER CLOSET 2 4 8 O LAVATORY 2 1 2 306 4-COMPARTMENT WITH GREASE TRAP 1 6 6 TOTAL 68 SPECIAL NOTES ALL INDIRECT WASTE OR WASTE PIPING RECEIVING THE DISCHARGE FROM A 4-COMP. SINK, STEAMER OR SIMILAR PIECE OF EQUIPMENT WHICH PRODUCES WATER AT A TEMPERATURE HIGHER THAN 125T SHALL BE DWV COPPER OR CAST IRON 10'-0" (MIN) DOWNSTREAM FROM THE FROM THE OUTLET PRODUCING SUCH DISCHARGE. COORDINATE NTH EQUIPMENT SUPPLIER. CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288.0681 F :: 317. 288. 0753 DRAWN BY: MMD CHECKED BY: KDH OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 8717954 tesengineering.com 0�I;IsreRFo v i No.19800267 T� N A1111VVVVVV\\ THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXO_Li INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE AND ME NOT TO BE USED OR RITRODUCED. WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CU0.RAN ARCHTECTU0.E 0 WPY FIT201&CJRtANAVo1 ECNPE MOE'S RESTAURANT #0350 1424 WEST CARMEL DR. CARMEL, IN 46032 SOIL, WASTE, AND VENT PLUMBING PLAN ISSUE DATE REVISION 2 01-10-18 REVISION 3 05-14-19 AEYM 4 W27-19 PROJECT #: 180316 P 1.0