HomeMy WebLinkAboutA211DOOR SCHEDULE
If DIMENSIONS DOOR FRAME HARDWARE REM.
3'-0'k8'-0'kl3/"
TYPE
DI
MATERIAL
EUSE/MATCH
EXISTING
FINISH
ONESTAIN TO
MATCH EXIST.
TYPE
I
MATERIAL
TIMELY
FINISH
MATCH
EXIST.
OL
Ol
Rl
02
3'-0'k8'-0'k13/"
Dl
REUSE/MATCH
EXISTING
STAIN TO
MATCH EXIST.
I
TIMELY
MATCH
EXIST.
OL
RI
03
3'-0N8'-0NIY;'
DlREUSE/MATCH
EXISTING
STAIN TO
MATCH EXIST.
I
TIMELY
MA TCH
EXIST.
OL
RI
04
3'-0'k8'-0'k13/4"
IEXISTING
REUSE/MATCHSTAIN
TO
MATCH EXIST.
F2
TIMELY
MATCH
EXIST.
OL
RI
05
3'-0'k8'-0'k13/"
IIOL
EUSE/MATCH
EXISTING
STAIN TO
MATCH EXIST.
TIMELY
MATCH
EXIST.
RI
06
3'-0'k8'-0'k13/"
I
REUSE/MATCH
EXISTING
STAIN TO
MATCH EXIST.
ITIMELY
MATCH
EXIST.
OL
RI
3'-0'k8'-0'k13/"
I
EUSE/MATC
STAIN TO
MATCH EXIST.
FI
TIMELY
MATCHEXISTING
EXIST,
FO7
3'-0N8'-0NIY;'
Dl
EUSE/MATC
STAIN TO
MATC
TCH EXIST.
F2TIMELYMAEXISTING
EXIST,
3'-ONFULL HEIGHT
D3
HERCULITE GLASS SYSTEM
I DRYWALL WRAPPED OPENING
EL, CR, CL, PP
R2
DOOR/FRAME TYPES
D1 D2
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City Df Camel
�N;K��1tD,A
DATE: 08/02/19
D3
ROVIDE ONE
LOCKING LADDER PULL
ON EACH S1DE OF
DOOR TOTAL COUNT
21, AS NOTED IN
REMARKS
E"'i,1�I' ii411
11�11
REMARKS
RI. PROVIDE V I NYL FILM; LWMAR, FROST SERIES 36"ROLL, GLACIER
NRM55 P54. DESIGN INTENT IS FOR FILM TO BE INSTALLED FROM
2'-6" AFF TO 5'-6" AFF.
R2. PROVIDE ADA COMPLIANT C.R. LAURENCE BRUSHED STAINLESS 60"
LOCKING LADDER PULL#LLPA60BS. PROVIDE VINYL FILM ON
DOOR. DESIGN INTENT IS FOR FILM STYLE AND PLACEMENT TO
MATCH TENANT'S EXISTING SUITTE DOUBLE DOOR ENTRY. CONFIRM
EXACT REQUIREMENTS WITH TENANT.
HARDWARE LEGEND
CL CLOSER
CH COATHOOK
CR CARD READER BY TENANT(N.LC.)
DB DEADBOLT
DL DUMMY LEVER
EL ELECTROMAGNETIC LOCK (PER IBC 2012)
ES ELECTRIC STRIKE BY TENANT(N.LC.)
H HOLD OPEN
KP KICK PLATE
KS KICK STOP
OL OFFICE LOCKSET
PH PANIC HARDWARE
PL PRIVACY LOCKSET
PP PUSH/PULL
PS PASSAGE LATCHSET
PV PIVOT HINGE
RL ROLLER LATCHES
SL STOREROOM LOCKSET
TS TOP STRIKES
F1 F2
DOOR/FRAME NOTES
I. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP
EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD
DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS
TO MATCH EXISTING. PRE -MACHINE NEW DOORS FOR CYLINDRICAL
LOCKSETS.
2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE
EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE, FOR NEW
DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD.
PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED. REUSE
EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING
REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS,
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
• 7'0 HT, TO HAVE 3 HINGES
• GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES
• FINISH TO MATCH HARDWARE SET
8. PROVIDE (I I SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE)AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
MIS DRAWING, AND ME IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WRHOLR THE WRITTEN
CONSENT OF SCHOTT DESIGN.
CRIPTION
ff
ETEi
REVISIONS
PROJECT NUMBER
2018.479
PROD. MGR DRAWN BY
BW BW
2ND FLOOR
DOOR SCHEDULE
A21 I