Loading...
HomeMy WebLinkAboutD111LEGEND RECYCLING NOTES GENERAL NOTES PLAN NOTES EXISTING TO BE REMOVED EXISTING TO REMAIN WALL WALL o—xxx PARTIAL HEIGHT WALL xxxxxx: PARTIAL HEIGHT WALL i DOOR AND FRAME xo--tx WINDOW/SIDELIGHT I I CEILING GRID AND 7_-_—r TILES, 2'x4' CEILING GRID AND i--?--r TILES, 2x2' 9-/ �i�� SUPPLY AIR DIFFUSERS e �v commas EXHAUST FAN L-J LIGHT FIXTURE, FLUORESCENT, 2'x4' q=1 LIGHT FIXTURE, L_J11 FLUORESCENT, 2'x2' LIGHT FIXTURE, CAN P----+ LIGHT FIXTURE, FLUORESCENT "fir+ LIGHT FIXTURE, TRACK tk LIGHT FIXTURE, LIGHT FIXTURE, 05) PENDANT $ LIGHTSWITCH EXIT LIGHT q�y^ C-] EMERGENCY LIGHT T�VD)1l ELECTRIC OUTLETS) DATA OR Ir COMMUNICATION OUTLET 7 DOOR AND FRAME x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THATARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/02/19 DECONSTRUCTION MANAGEMENT CHECKLIST CO -MINGLE SORT REQUIRED THIS CHECKLIST ONLY APPLIES TO ITEMS BEING REMOVED. REFER TO DECONSTRUCTION PLAN. CO-MINGLE/LEED CONTAINER REQUIRED FOR RECYCLING. CONTAINER: w w ITEM BEING REMOVED z u z REMARKS xZ wi ¢p w0 DU :U U Yo DOORS REUSE ALL EXISTING DOORS IN NEW LAYOUT WHERE POSSIBLE FRAMES ✓ DOOR HARDWARE REUSE ALL EXISTING HARDWARE IN NEW LAYOUT WHERE POSSIBLE METAL LIGHT BOXES CASEWORK UNIT ✓ CARPET TILE ✓ BROADLOOM CARPET ✓ APPLIANCES ✓ GENERAL SORTING REQUIREMENTS (AS APPLICABLE): LEED CO -MINGLE RECYCLING CONTAINER: SHIPPING/PACKAGING, WOOD STUDS, WOOD TRIM, HVAC COMPONENTS, CEILING GRID, METAL STUDS, WIRING/ CONDUIT, AND OUTLETS/SWITCHES TRASH CONTAINER: DRYWALL, INSULATION, VINYL BASE, VCT, WALLCOVERING, CEILING TILES AND LVT (LUXURY VINYL TILE) CONTACTS: KRUSE CARPET RECYCLING: COORDINATE PICK UP AND REQUIREMENTS WITH SUSAN SHAFER 317.337.1950 CARPET RECYCLING: KRUSE PICKUP AND RECYCLING FEES ARE TO BE PAID THROUGH SCHOTT DESIGN'S NO COST ADD PROGRAM. NOTE: THE DEMOLITION CREW/GENERAL CONTRACTOR WILL NO LONGER BE PAYING THE CARPET DISPOSAL TIPPING FEES AT THE LANDFILL. CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION. I. CARPET BEING REMOVED TO BE RECYCLED VIA KRUSE CARPET RECYCLING. COORDINATE REQUIREMENTS AND PICK UP WITH SUSAN SHAFER (317) 337-1950. 2. CARPET TILES SHOULD BE PALLETIZED; BROADLOOM SHOULD BE PILED NEATLY. 3. COLLECT DOCUMENTATION FROM KRUSE AS PROOF OF RECEIVAL FORWARD TO THE GENERAL CONTRACTOR. I. REFER TO ALL DEC ONSTRUCTI ON NOTES ON TITLES HEETTI H. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECTOR BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER TO THE DECONSTRUCTION MANAGEMENT CHECKLIST BELOW. 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. 4. REMOVE EXISTING CEILING TILES AND 2X4 LIGHT FIXTURES THROUGHOUT EXPANSION AREA, UNLESS OTHERWISE NOTED. EXISTING CEILING GRID TO REMAIN. REFER TO DECONSTRUCTION CHECKLIST FOR PROPER RECYCLING METHOD OF LIGHT FIXTURES. Dot REMOVE EXISTING CABINETRY AND COUNTERTOP. REFER TO DECONSTRUCTION CHECKLIST FOR PROPER RECYCLING METHOD. D02 REMOVE EXISTING SINK. NO SERVICE SINKS ARE BEING REMOVED. D03 REMOVE EXISTING COAT ROD AND SHELF. ODESIGN INTENT IS FOR ALL METAL OUTLET/DATA BOXES AND/OR D04 WIRE MOLD ON EXTERIOR WINDOW LINE WITHIN THIS ROOM TO BE REMOVED. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED. ® AREA NOT IN CONTRACT DECONSTRUCTION PLAN ❑ AREA OF WORK 0 2 4 8 16 NC THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE I NTEILECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOIT DESIGN. N N LU CD ZCN C0 E � O LU Z WZ H N `a}Z111 z0 Q 1 XLU Q W�0 Zz r Q r ISSUE DATE DESCRIPTION 06.17.19 REVIEWSET 06.19.19 PERMITSET REVISIONS PROJECT NUMBER 2018.479 PROJ.MGR DRAWN BY 2ND FLOOR DECONSTRUCTION PLAN DIII