HomeMy WebLinkAboutE111LEGEND
NEW CONSTRUCTION
EXISTING TO REMAIN
POWER OUTLET. DUPLEX
POWER OUTLET. DUPLEX
POWER OUTLET
POWER OUTLET
QUADRUPLE%
QUADRUPLE%
JQ
JUNCTION BOX
QJ
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX. BLANK COVER PLATE
BOX, OPEN
QO
BOX, OPEN
P
PROVIDE JUNCTION BOX
P
POWER AND DATA POLE
D
ABOVE CEILING FOR
O
POWER POLE
CONNECTION, POWER
POLE BY OTHERS.
FLOOR BOX WTH POWER
FLOOR BOX WITH POWER
FI®
AND DATA, FLUSH
6b
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
®
JUNCTION BOX AND
F0141
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
DATA/COMMUNICATION
11
OUTLET (PROVIDE BOB
b
AND PULLSTRING ONLY)
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42'
HEIGHT OF ELECTRICAL
OR DATA DEVICE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
DATE: 08/02/19
GENERAL NOTES
I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO INSTALLED I B"MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND
MUST COMPLY WITH ALL APPLICABLE CODES.
PLAN NOTES
Eol COORDINATE COPIER RECEPTACLE WITH TENANT, PROVIDE
DEDICATED RECEPTACLE AS REQUIRED.
E02 PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE
SYSTEM, COORDINATE EXACT LOCATION WITH TENANT'S
FURNITURE VENDOR.
EOJ PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE
FOR POWER AND DATA, COORDINATE WITH TENANTS FURNITURE
VENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE
SU BMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING.
E04 IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOX TO NEW
RECEPTACLE AS SHOWN. IF NOT POSSIBLE, REMOVE BLANK/OPEN
BOX AND PROVIDE NEW RECEPTACLE ATTHIS LOCATION.
E05 PROVIDE MAG-LOCK HARDWARE AND POWER AS REQUIRED TO
HERCU LITE DOOR. SEE DOOR SCHEDULE FOR MORE DETAILS. ALL
CARD READER HARDWARE TO BE PROVIDED AND INSTALLED BY
TENANTS SECURITY VENDOR, COORDINATE WITH VENDOR FOR
MORE INFORMATION.
E06 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT
LOCATION WITH TENANT.
® AREA NOT IN CONTRACT ELECTRICAL PLAN
❑ AREA OF WORK 0 2 4 8 16 N I<)
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC.. AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
N
N
W
CD
ZCN
C0
1 �
O LL
Z WZ
LU
I—
N cn
aZzo
>aoE
2XWQ
W:*0
zz
T-
0
Q
0
ISSUE
DATE
DESCRIPTION
06.17.19
REVIEW SET
06.19.19
PERMITSET
REVISIONS
PROJECT NUMBER
2018.479
PROD. MGR DRAWN BY
2ND FLOOR
ELECTRICAL PLAN
E111