Loading...
HomeMy WebLinkAboutL100TRAVEL DISTANCE = 122'-1" AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all mgulatims of State and Local Codes City d Camel DATE: 08/02/19 ENLARGED LIFE SAFETY PLAN 0 4' 8' 16' CODE SUMMARY SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT OUT OFFICE SPACE PREVIOUS USE OF SPACE BIUSINESSI OCCUPANCY CLASSIFICATION BIUSINESSI CHANGE OF OCCUPANCY CLASS9 NO TOTAL BUILDING AREA 32,209 SF/FLOOR X 1 4 STORIES = 128,836 SF TOTAL PROJECT AREA Emw OCCUPANCY CALCULATIONS NUMBER OF EXITS 2561 SF SPACE TYPE AREA I SF PER OCCUPANT OCCUPLOAD GEN. OFFICE 2,561 SF 1 100 26 TOTAL OCCUPANTS IN PROJECT AREA 26 REQUIRED:I PROVIDED SPRINKLER SYSTEM(YES/NO) YES- EXISTING TO REMAIN TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 32,209 SF ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN) BUILT BEFORE 19788 NO BUILDING CONSTRUCTION TYPE II-B Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT- BUILDING STAIR LOCATION TIFF FIRE EXTINGUISHER ® EXITSIGN 11(1�® EMERGENCYLIGHT — — — TRAVEL DISTANCE OVERALL BUILDING NOT TO SCALE GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. E2. EXISTING COMMON CORRIDOR TO REMAIN. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT P FOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AN D LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. NC THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH OII DESIGN. r ISSUE DATE DESCRIPTION 06.17.19 REVIEW SET 06.19.19 PERMIT SET PROJECT NUMBER 2018.479 2ND FLOOR LIFE SAFETY L 100