HomeMy WebLinkAboutA111ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN mr WALL WALL PARTIAL HEIGHT WALL ® PARTIAL HEIGHT WALL E=E25 �o WINDOW/SIDELIGHT a~o: WINDOW/SIDELIGHT ® DOORANDFRAME (SEE DOOR SCHEDULE) 77 DOORAND FRAME NOT: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE WI UNLESS OTHERWISE NOTED. PROVIDE MOISTURE R ISTANT/GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. F WALL WITH INSULATION ( 3S/e" METAL STUDS AT I6"O.CJ 11 C)' ONE LAYER OF 5%" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2-0 EACH EACH SIDE OF WALL ABOVE CEILING RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/02/19 WALL THICKNESS METAL STUD EXISTING WIN MULLION PRE -FINISHED ALUMINUM RECEIVER TRIM- FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINEOFEXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT n WALL AT MULLION DETAIL Al l l NOT TO SCALE GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PUN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. PLAN NOTES AOt ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. A02 NEW FIRE EXTINGUISHER AND SEMI -RECESSED FIRE EXTINGUISHER CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR, CABINET TO BE PAINTED TO MATCH ADJACENT WALL. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. ODESIGN INTENT 15 FOR NEW WALL TO ALIGN WITH EDGE OF A03 WINDOW. CONTRACTOR TO CONFIRM EXACT LOCATION IN FIELD TO ENSURE ACCURATE WALL PLACEMENT. PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A04 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. AREA NOTIN CONTRACT ARCHITECTURAL PLAN AREA OF WORK 0 ] 4 8 16 NC TH S DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT ME WRITTEN CONSENT OF SCH07 DESIGN. O N N I H O Z`�� N FNO O LL Z WZ H aN vj Zz0 Gaon 2XW< Whin Zz r 0 Q r ISSUE DATE DESCRIPTION 06.17.19 REVIEW SET 06.19.19 PERMITSET REVISIONS PROJECT NUMBER 2018.479 PROD. MGR DRAWN BY I BW BIN 2ND FLOOR ARCHITECTURAL FLOOR PLAN A111