HomeMy WebLinkAboutA121LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4', FLUORESCENT, BUILDING m FLUORESCENT, BUILDING STANDARD INDIRECT, DIRECT STANDARD INDIRECT/DIRECT B EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE Jr EXIT/EMERGENCY LIGHT FIXTURE COMBO $N LIGHTSWITCH $N3 LIGHTSWITCH, 3-WAY *ND LIGHTSWITCH, DIMMER $NP SWITCH, PROJECTOR SCREEN $NG SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP( $NE SWITCH, EXHAUST FAN i — N LIGHT CIRCUIT ® EXIT LIGHT FIXTURE &0w EMERGENCY LIGHT FIXTURE 4e EXIT/EMERGENCY LIGHT FIXTURE COMBO LIGHTSWITCH $3 LIGHTSWITCH,&WAY sD LIGHTSWITCH, DIMMER pP SWITCH, PROJECTOR SCREEN $G SWITCH, GARBAGE DISPOSAL 3'E SWITCH, EXHAUST FAN LIGHTCIRCUIT III CEILING GRID, CEILING GRID, J—L—L SUSPENDED, 2'x2' SUSPENDED, 2'x2' mRELOCATED DIFFUSER, [ADIFFUSER, LAY -IN, 2'x2' LAY IN, 2'x2' ® RELOCATED DIFFUSER, ® DIFFUSER, LAY IN, I'M' DAY -IN, I'x4' RELOCATED DIFFUSER, m DIFFUSER, LAY -IN, 4"M LAY -IN, 4"x4' ® EXHAUST FAN, 2'x2' EXHAUST FAN, 2'x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTTUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS & nMECHANICAL DIFFUSER RELOCATION RELEASED FOR CONSTRUCTION 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/02/19 GENERAL NOTES I. PROVIDE NEW BUILDING STANDARD CEILING TILE AND REUSE EXISTING CEILING GRID, UNLESS OTHERWISE NOTED. EXISTING GRID IS 2 x2 AT 8'-S'A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY, IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILU RE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE TEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION, IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90, I, CONTRACTOR MUST NOTIFY SDI. OVER 50%OF THE LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MEr. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED, 6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 7. ELECTRICAL WORK IS LIMBED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AN D LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, PLAN NOTES R01 TIE IN NEW AND EXISTING LIGHT FIXTURES TO EXISTING CIRCUIT AND EXISTING LIGHTSWITCH. IF NOT POSSIBLE, PROVIDE NEW LIGHT SWITCH AS REQUIRED. ® AREA NOT IN CONTRACT REFLECTED CEILING PLAN ❑ AREA OF WORK 0 ]' 4' 8' 16' N C of IS DRAWING, AND THE IDEAS, DEIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH OII DESIGN. O N N W CD Z`�� N 1 O LU Z WZ PRaPR� �/ N v> `aTZzti Q in = x w Q Li I zz T- 0 Q 0 ISSUE DATE DESCRIPTION 06.17.19 REVIEW SET 06.19.19 PERMITSET REVISIONS PROJECT NUMBER 2018.479 PROJ. MGR DRAWN BY BW BW 2ND FLOOR REFLECTED CEILING PLAN Al 21