HomeMy WebLinkAboutA121LEGEND
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE, 2'x4', LIGHT FIXTURE, 2'x4',
FLUORESCENT, BUILDING m FLUORESCENT, BUILDING
STANDARD INDIRECT, DIRECT STANDARD INDIRECT/DIRECT
B
EXIT LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE
Jr EXIT/EMERGENCY LIGHT
FIXTURE COMBO
$N LIGHTSWITCH
$N3 LIGHTSWITCH, 3-WAY
*ND LIGHTSWITCH, DIMMER
$NP SWITCH, PROJECTOR
SCREEN
$NG SWITCH, GARBAGE
DISPOSAL (ABOVE
COUNTERTOP(
$NE SWITCH, EXHAUST FAN
i — N LIGHT CIRCUIT
®
EXIT LIGHT FIXTURE
&0w
EMERGENCY LIGHT FIXTURE
4e EXIT/EMERGENCY LIGHT
FIXTURE COMBO
LIGHTSWITCH
$3 LIGHTSWITCH,&WAY
sD LIGHTSWITCH, DIMMER
pP
SWITCH, PROJECTOR
SCREEN
$G
SWITCH, GARBAGE
DISPOSAL
3'E SWITCH, EXHAUST FAN
LIGHTCIRCUIT
III CEILING GRID, CEILING GRID,
J—L—L SUSPENDED, 2'x2' SUSPENDED, 2'x2'
mRELOCATED
DIFFUSER,
[ADIFFUSER,
LAY -IN, 2'x2'
LAY IN, 2'x2'
®
RELOCATED DIFFUSER,
®
DIFFUSER,
LAY IN, I'M'
DAY -IN, I'x4'
RELOCATED DIFFUSER,
m
DIFFUSER,
LAY -IN, 4"M
LAY -IN, 4"x4'
®
EXHAUST FAN, 2'x2'
EXHAUST FAN,
2'x2'
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTTUTED FOR NEW. NO NEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELOCATE DIFFUSERS &
nMECHANICAL DIFFUSER RELOCATION
RELEASED FOR CONSTRUCTION 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/02/19
GENERAL NOTES
I. PROVIDE NEW BUILDING STANDARD CEILING TILE AND REUSE
EXISTING CEILING GRID, UNLESS OTHERWISE NOTED. EXISTING GRID IS
2 x2 AT 8'-S'A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR
ANY DAMAGED GRID.
2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE
TO CREATE UNIFORM LOOK.
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY, IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILU RE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE TEMS AT THEIR EXPENSE.
4. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION, IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90, I,
CONTRACTOR MUST NOTIFY SDI. OVER 50%OF THE LIGHTING WILL
BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MEr.
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED,
6. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
7. ELECTRICAL WORK IS LIMBED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AN D
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES,
PLAN NOTES
R01 TIE IN NEW AND EXISTING LIGHT FIXTURES TO EXISTING CIRCUIT
AND EXISTING LIGHTSWITCH. IF NOT POSSIBLE, PROVIDE NEW
LIGHT SWITCH AS REQUIRED.
® AREA NOT IN CONTRACT REFLECTED CEILING PLAN
❑ AREA OF WORK 0 ]' 4' 8' 16' N C
of IS DRAWING, AND THE IDEAS,
DEIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH OII DESIGN.
O
N
N
W
CD
Z`��
N
1
O LU
Z WZ
PRaPR� �/
N v>
`aTZzti
Q in
= x w Q
Li I
zz
T-
0
Q
0
ISSUE
DATE
DESCRIPTION
06.17.19
REVIEW SET
06.19.19
PERMITSET
REVISIONS
PROJECT NUMBER
2018.479
PROJ. MGR DRAWN BY
BW BW
2ND FLOOR
REFLECTED
CEILING PLAN
Al 21