HomeMy WebLinkAboutGN 004 04" CONC.
SLAB ON GRADE
6"-8" MIN,
GRAN. FILL
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND, WALL
00
00
00
oa
0
00
00
o
°
00
0
0
0
314" INSULATION SHEATHING
BRICK VENEER
TYPICAL FOUNDATION WALL:
8" POURED CONCRETE WALL
SILL ANCHOR BOLTS @ 6'-0" O.C.
SAND WITHIN 12" OF CORNERS
16 X 8 CONC. FOOTING
LOOP WIRE REINFORCING
FOUNDATION WALL at GARAGE - BRICK def.422
CRAWL and BASEMENT FOUNDATIONS SCALE: 3/4"=l'-0"
314" FLOOR DECKING NOTE: OFFSET FACE OF STUD 112"
SEE FLOOR FRAMING FROM FACE OF FOUND. WALL
PLAN FOR JOIST LAYOUT
2x4 TREATED
PLATE
TYPICAL FOUNDATION WALL:
8" POURED CONCRETE WALL
SILL ANCHOR BOLTS @ 6'-0" O.C.
#6 VERTICAL REINFORCEMENT SET 24" O.C.
@ 5" FROM SOIL SIDE OF WALL
16"x8" CONCRETE FOOTING
#3 STEEL WALL REINFORCING
LOOP WIRE REINFORCING
4" CONCRETE SLAB ON GRADE
WI6 MIL. VAPOR BARRIER
3-112" DIA. NOTE: OFFSET FACE OF STUD 112"
FETAL ANCHOR PLATE ADJUSTABLE STEEL FROM FACE OF FOUND, WALL
COLUMN
112" DRYWALL
4" CONCRETE SLAB ON GRADE
WI 6 MIL, VAPOR BARRIER 4" MIN. GRANULAR FILL 2x4 TREATED
ON 6 MIL. VISQUEEN SILL PLATE
,VAPOR BARRIER
4" CONIC, SLAB ON GRADE w
00 00 00 00000. 00 \
LLJ o 0 0 0 0
00 00 0 00 00
0. 0
00
00 0
00
SEE FOUNDATION PLAN WIDTH °
FOR PAD DIMENSIONS GRANULAR FILL
=
n
� � V
o °o 0 o °o
4" MIN. 0000 0
GRANULAR FILL 11
4" DRAIN TILE
FOUNDATION WALL at HOUSE - SIDING
PART'L and FULL BASEMENT FOUNDATIONS
(2) RISERS AT 7-314" EACH
(1) 9" TREAD
4" CONC. SLAB ON GRADE
8" MIN. GRANULAR FILL
WATERPROOFING
GRANULAR FILL TO
12" ABOVE TOP OF
CONCRETE FOOTING
4" DRAIN TILE
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND, WALL
SLOPE 2" TO DOOR
FOUNDATION WALL at GARAGE REAR
FULL BASEMENT FOUNDATIONS
A
SIDING
314" INSULATION SHEATHIN
2x4 TREATED PLATE
TYPICAL FOUNDATION WALL:
8" POURRED CONCRETE WALL
4" CONIC
SILL ANCHOR BOLTS @ 6'-0" O.0
SLAB ON GRADE
AND WITHIN 12 OF CORNERS
16"x8"CONCRETE FOOTING
_
SLOPE 2" TO D00
r
LOOP WIRE REINFORCING
24 GRADE
0. °o 0o
CXD
1'-4"
TYPICAL FOUNDATION at STEEL COLUMN def.esfF25 /`F22�7�
FOUNDATION WALL at GARAGE - SIDING dl.estF21
SLAB and BASEMENT FOUNDATIONS SCALE: 3/4"=V-0" CRAWL and BASEMENT FOUNDATIONS SCALE: 3/4"=l'-o"
OVERDIG
o °o °o °o
00 00 00 00
o 0. °o c)
o0 00 00
00 00 0
00 0.,
R-13 BATT INSULATION
WI2 MIL, VAPOR BARRIER
314" RIGID INSULATION
SIDING
1x BAND BOARD WI
GRADE DRIP EDGE
(SEE ELEV.)
WATERPROOFING
R-13 BATT INSULATION
WI2 MIL. VAPOR BARRIER
�-314" FLOOR DECKING
GRANULAR FILL
TO 12" ABOVE
TOP OF FOOTING
4" DRAIN TILE
SEE FLOOR FRAMING
PLAN FOR JOIST LAYOUT
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND. WALL
314" FLOOR DECKING
SEE FLOOR FRAMING
PLAN FOR JOIST LAYOUT
TYPICAL FOUNDATION WALL:
8" POURRED CONCRETE WALL
SILL ANCHOR BOLTS @ 6'-0" O.C.
AND WITHIN 12" OF CORNERS
16"x8" CONCRETE FOOTING
LOOP WIRE REINFORCING
PERIMETER INSULATION
DOWN TO GRANULAR FILL
o° o° o
4" MIN. GRANULAR FILLCXD
UNDER 4 MIL, VISQUEEN 1' 4„
VAPOR BARRIER
det.estF31 I F32 FOUNDATION WALL at HOUSE - SIDING
SCALE; 314" =1'-0"
2x4 TREATED
WOOD PLATE TYPICAL FOUNDATION WALL:
8" POURED CONCRETE WALL
SILL ANCHOR BOLTS @ 6'-0" O.C.
16"X8" CONCRETE FOOTING
#3 STEEL WALL REINFORCING
2" FROM FACE OF WALL
LOOP WIRE REINFORCING
4" CONC. SLAB ON GRADE
WI6 MIL. VAPOR BARRIER
4" DRAIN TILE
4" GRANULAR FILL
det.estF33
SCALE: 314" =1' 0"
CRAWL and BASEMENT FOUNDATIONS
6"-8" MIN.
GRANULAR FILL
OVERDIG
314" FLOOR DECKING
SEE FLOOR FRAMING
PLAN FOR JOIST LAYOUT
(2) RISER AT 7-314" EACH
(1) 9 TREAD
PERIMETER INSULATION
DOWN TO GRANULAR FILL
0. 0
TYPICAL FOUNDATION WALL.
8" POURED CONCRETE WALL
o o SILL ANCHOR BOLTS @ 6'-0" O.C.
0. ° ° ° ° AND WITHIN 12" OF CORNERS
CXD 16"x8" CONCRETE FOOTING
1'-4" LOOP WIRE REINFORCING
4" MIN. GRANULAR FILL
UNDER 6 MIL. VISQUEEN
VAPOR BARRIER
FOUNDATION WALL at GARAGE REAR def.esfF28
FOUNDATION WALL ai GARAGE REAR
R-13 BATT INSULATION
WI2 MIL. VAPOR BARRIER
-314" RIGID INSULATION
-SIDING
1x BAND BOARD WI
DRIP EDGE
(SEE ELEV.)
- 2x4 TREATED PLATE
GRADE
SCALE: 314" =1' 0"
314" RIGID INSULATION
R-13 BATT INSULATIO
WI2 MIL. VAPOR BARRIE
METAL TIE
BRICK VENEER
THROUGH WALL FLASHING
GRADE
OVERDIG
NOTE: OFFSET FACE OF STUD 112"
N FROM FACE OF FOUND. WALL
R 314" FLOOR DECKING
SEE FLOOR FRAMING
PLAN FOR JOIST LAYOUT
G PERIMETER INSULATION
DOWN TO GRANULAR FILL
TYPICAL FOUNDATION WALL:
8" POURED CONCRETE WALL
SILL ANCHOR
AND WITHIN 12" OF CORNERS
16"x8" CONCRETE FOOTING
LOOP WIRE REINFORCING
O O O 0
o° o° o
CXD 4" MIN, GRANULAR FILL
1'4" UNDER 6 MIL, VISQUEEN
VAPOR BARRIER
FOUNDATION WALL at HOUSE- BRICK det.esfF30
CRAWL and PART'L BASEMENT FOUNDATIONS SCALE: 314" = 1'41
NOTE: OFFSET FACE OF STUD 112"
FROM FACE OF FOUND. WALL BRICK VENEER
2x4 TREATED
SILL PLATE
4" CONC. SLAB ON GRADE
WI6 MIL. VAPOR BARRIER
6".8"MIN. COD
faf
GRANULAR FILL
00 00 00 00 00
00 0
00
00 0
0. O
/___314"INSULATINSHEATHING
TYPICAL FOUNDATION WALL:
12" POURRED CONCRETE WALL
SILL ANCHOR BOLTS @ 6'-0" O.C.
AND WITHIN 12" OF CORNERS
20"x8" CONCRETE FOOTING
;LOOP WIRE REINFORCING
GRADE
OVERDIG
4"
FOUNDATION WALL at GARAGE - BRICK RETURNS det.estF44
CRAWL and BASEMENT FOUNDATIONS
SCALE: 314" =1' 0"
UA
w
w
w
w
w
w
���QQQQ
UA
(D 2011
cl
w
z
Q
cn
0
w
Q
z
I-_
U
w
�
z
O
w
O
O
U
H
a
U
O
O
02/21 /2012
SDI