HomeMy WebLinkAboutGN 004 04" CONC. SLAB ON GRADE 6"-8" MIN, GRAN. FILL NOTE: OFFSET FACE OF STUD 112" FROM FACE OF FOUND, WALL 00 00 00 oa 0 00 00 o ° 00 0 0 0 314" INSULATION SHEATHING BRICK VENEER TYPICAL FOUNDATION WALL: 8" POURED CONCRETE WALL SILL ANCHOR BOLTS @ 6'-0" O.C. SAND WITHIN 12" OF CORNERS 16 X 8 CONC. FOOTING LOOP WIRE REINFORCING FOUNDATION WALL at GARAGE - BRICK def.422 CRAWL and BASEMENT FOUNDATIONS SCALE: 3/4"=l'-0" 314" FLOOR DECKING NOTE: OFFSET FACE OF STUD 112" SEE FLOOR FRAMING FROM FACE OF FOUND. WALL PLAN FOR JOIST LAYOUT 2x4 TREATED PLATE TYPICAL FOUNDATION WALL: 8" POURED CONCRETE WALL SILL ANCHOR BOLTS @ 6'-0" O.C. #6 VERTICAL REINFORCEMENT SET 24" O.C. @ 5" FROM SOIL SIDE OF WALL 16"x8" CONCRETE FOOTING #3 STEEL WALL REINFORCING LOOP WIRE REINFORCING 4" CONCRETE SLAB ON GRADE WI6 MIL. VAPOR BARRIER 3-112" DIA. NOTE: OFFSET FACE OF STUD 112" FETAL ANCHOR PLATE ADJUSTABLE STEEL FROM FACE OF FOUND, WALL COLUMN 112" DRYWALL 4" CONCRETE SLAB ON GRADE WI 6 MIL, VAPOR BARRIER 4" MIN. GRANULAR FILL 2x4 TREATED ON 6 MIL. VISQUEEN SILL PLATE ,VAPOR BARRIER 4" CONIC, SLAB ON GRADE w 00 00 00 00000. 00 \ LLJ o 0 0 0 0 00 00 0 00 00 0. 0 00 00 0 00 SEE FOUNDATION PLAN WIDTH ° FOR PAD DIMENSIONS GRANULAR FILL = n � � V o °o 0 o °o 4" MIN. 0000 0 GRANULAR FILL 11 4" DRAIN TILE FOUNDATION WALL at HOUSE - SIDING PART'L and FULL BASEMENT FOUNDATIONS (2) RISERS AT 7-314" EACH (1) 9" TREAD 4" CONC. SLAB ON GRADE 8" MIN. GRANULAR FILL WATERPROOFING GRANULAR FILL TO 12" ABOVE TOP OF CONCRETE FOOTING 4" DRAIN TILE NOTE: OFFSET FACE OF STUD 112" FROM FACE OF FOUND, WALL SLOPE 2" TO DOOR FOUNDATION WALL at GARAGE REAR FULL BASEMENT FOUNDATIONS A SIDING 314" INSULATION SHEATHIN 2x4 TREATED PLATE TYPICAL FOUNDATION WALL: 8" POURRED CONCRETE WALL 4" CONIC SILL ANCHOR BOLTS @ 6'-0" O.0 SLAB ON GRADE AND WITHIN 12 OF CORNERS 16"x8"CONCRETE FOOTING _ SLOPE 2" TO D00 r LOOP WIRE REINFORCING 24 GRADE 0. °o 0o CXD 1'-4" TYPICAL FOUNDATION at STEEL COLUMN def.esfF25 /`F22�7� FOUNDATION WALL at GARAGE - SIDING dl.estF21 SLAB and BASEMENT FOUNDATIONS SCALE: 3/4"=V-0" CRAWL and BASEMENT FOUNDATIONS SCALE: 3/4"=l'-o" OVERDIG o °o °o °o 00 00 00 00 o 0. °o c) o0 00 00 00 00 0 00 0., R-13 BATT INSULATION WI2 MIL, VAPOR BARRIER 314" RIGID INSULATION SIDING 1x BAND BOARD WI GRADE DRIP EDGE (SEE ELEV.) WATERPROOFING R-13 BATT INSULATION WI2 MIL. VAPOR BARRIER �-314" FLOOR DECKING GRANULAR FILL TO 12" ABOVE TOP OF FOOTING 4" DRAIN TILE SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT NOTE: OFFSET FACE OF STUD 112" FROM FACE OF FOUND. WALL 314" FLOOR DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT TYPICAL FOUNDATION WALL: 8" POURRED CONCRETE WALL SILL ANCHOR BOLTS @ 6'-0" O.C. AND WITHIN 12" OF CORNERS 16"x8" CONCRETE FOOTING LOOP WIRE REINFORCING PERIMETER INSULATION DOWN TO GRANULAR FILL o° o° o 4" MIN. GRANULAR FILLCXD UNDER 4 MIL, VISQUEEN 1' 4„ VAPOR BARRIER det.estF31 I F32 FOUNDATION WALL at HOUSE - SIDING SCALE; 314" =1'-0" 2x4 TREATED WOOD PLATE TYPICAL FOUNDATION WALL: 8" POURED CONCRETE WALL SILL ANCHOR BOLTS @ 6'-0" O.C. 16"X8" CONCRETE FOOTING #3 STEEL WALL REINFORCING 2" FROM FACE OF WALL LOOP WIRE REINFORCING 4" CONC. SLAB ON GRADE WI6 MIL. VAPOR BARRIER 4" DRAIN TILE 4" GRANULAR FILL det.estF33 SCALE: 314" =1' 0" CRAWL and BASEMENT FOUNDATIONS 6"-8" MIN. GRANULAR FILL OVERDIG 314" FLOOR DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT (2) RISER AT 7-314" EACH (1) 9 TREAD PERIMETER INSULATION DOWN TO GRANULAR FILL 0. 0 TYPICAL FOUNDATION WALL. 8" POURED CONCRETE WALL o o SILL ANCHOR BOLTS @ 6'-0" O.C. 0. ° ° ° ° AND WITHIN 12" OF CORNERS CXD 16"x8" CONCRETE FOOTING 1'-4" LOOP WIRE REINFORCING 4" MIN. GRANULAR FILL UNDER 6 MIL. VISQUEEN VAPOR BARRIER FOUNDATION WALL at GARAGE REAR def.esfF28 FOUNDATION WALL ai GARAGE REAR R-13 BATT INSULATION WI2 MIL. VAPOR BARRIER -314" RIGID INSULATION -SIDING 1x BAND BOARD WI DRIP EDGE (SEE ELEV.) - 2x4 TREATED PLATE GRADE SCALE: 314" =1' 0" 314" RIGID INSULATION R-13 BATT INSULATIO WI2 MIL. VAPOR BARRIE METAL TIE BRICK VENEER THROUGH WALL FLASHING GRADE OVERDIG NOTE: OFFSET FACE OF STUD 112" N FROM FACE OF FOUND. WALL R 314" FLOOR DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT G PERIMETER INSULATION DOWN TO GRANULAR FILL TYPICAL FOUNDATION WALL: 8" POURED CONCRETE WALL SILL ANCHOR AND WITHIN 12" OF CORNERS 16"x8" CONCRETE FOOTING LOOP WIRE REINFORCING O O O 0 o° o° o CXD 4" MIN, GRANULAR FILL 1'4" UNDER 6 MIL, VISQUEEN VAPOR BARRIER FOUNDATION WALL at HOUSE- BRICK det.esfF30 CRAWL and PART'L BASEMENT FOUNDATIONS SCALE: 314" = 1'41 NOTE: OFFSET FACE OF STUD 112" FROM FACE OF FOUND. WALL BRICK VENEER 2x4 TREATED SILL PLATE 4" CONC. SLAB ON GRADE WI6 MIL. VAPOR BARRIER 6".8"MIN. COD faf GRANULAR FILL 00 00 00 00 00 00 0 00 00 0 0. O /___314"INSULATINSHEATHING TYPICAL FOUNDATION WALL: 12" POURRED CONCRETE WALL SILL ANCHOR BOLTS @ 6'-0" O.C. AND WITHIN 12" OF CORNERS 20"x8" CONCRETE FOOTING ;LOOP WIRE REINFORCING GRADE OVERDIG 4" FOUNDATION WALL at GARAGE - BRICK RETURNS det.estF44 CRAWL and BASEMENT FOUNDATIONS SCALE: 314" =1' 0" UA w w w w w w ���QQQQ UA (D 2011 cl w z Q cn 0 w Q z I-_ U w � z O w O O U H a U O O 02/21 /2012 SDI