95N - Solar Panel Specs
N330/N325 Quality and Reliability Panasonic’s vertical integration, 20 years of experience manufacturing HIT® and 20 internal tests beyond those mandated by current standards provides extreme quality assurance. Higher Efficiency 19.7% Enables higher power output and greater energy yields. HIT® provides maximum production for your limited roof space. Unique water drainage The water drainage system give rain, water and snow melt a place to go, reducing water stains and soiling on the panel. Less dirt on the panel means more sunlight getting through to generate power. Low Degradation HIT “N-type” cells result in extremely Low Light Induced Degradation (LID) and zero Potential Induced Degradation (PID) which supports reliability and longevity. This technology reduces annual degradation to 0.26% compare to 0.70% in conventional panels, guaranteeing more power for the long haul. Our competitive advantages High Efficiency at High Temperatures As temperature increases, HIT® continues to perform at high levels due to the industry leading temperature coefficient of -0.258% /⁰C. No other module even comes close to our temperature characteristics. That means more energy throughout the day. 25 Year Product and Performance Warranty** Industry leading 25 year product workmanship and performance warranty is backed by a century old company- Panasonic. Power output is guaranteed to 90.76% after 25 years, far greater than other companies. Panasonic’s unique heterojunction technology uses ultra-thin amorphous silicon layers. These thin dual layers reduce losses, resulting in higher energy output than conventional panels. Advanced bifacial cell designed for increased energy output. The cell utilizes sunlight reflected back from the rear side material which captures more light and converted into energy. n-type crystalline silicon Double-sided textured surface i-type amorphous layer Amorphous layer Transparent electrode (TCO) Lattice-type electrodes Finger Tab These amorphous silicon layers reduces the recombination ofelectrons to minimum level. Electrodes Ultra-thin amorphous silicon layer HIT® is a registered trademark of Panasonic Group CAUTION! Please read the installation manual carefully before using the products. Used electrical and electronic products must not be mixed with general household waste. For proper treatment, recovery and recycling of old products, please take them to applicable collection points in accordance with your national legislation. Panasonic Eco Solutions of North America Two Riverfront Plaza, 5th Floor, Newark, NJ 07102 panasonicHIT@us.panasonic.com business.panasonic.com/solarpanels All Rights Reserved © 2017 COPYRIGHT Panasonic Corporation Specifications are subject to change without notice 04/2017 RS17170_DS DEPENDENCE ON IRRADIANCE Reference data for model: VBHN330SA16 (Cell temperature: 25°C) PERFORMANCE WARRANTY 97% 90.76% 80% More power over 25 years N330/N325 ELECTRICAL SPECIFICATIONS Model VBHN330SA16 VBHN325SA16 Rated Power (Pmax)¹330W 325W Maximum Power Voltage (Vpm) 58.0V 57.6V Maximum Power Current (lpm)5.70A 5.65A Open Circuit Voltage (Voc) 69.7V 69.6V Short Circuit Current (lsc) 6.07A 6.03A Temperature Coefficient (Pmax) -0.258%/°C -0.258%/°C Temperature Coefficient (Voc) -0.16V/°C -0.16V/°C Temperature Coefficient (lsc) 3.34mA/°C 3.32mA/°C NOCT 44.0°C 44.0°C CEC PTC Rating 311.3W 306.5W Cell Efficiency 22.09%21.76% Module Efficiency 19.7%19.4% Watts per Ft.²18.3W 18.0W Maximum System Voltage 600V 600V Series Fuse Rating 15A 15A Warranted Tolerance (-/+)+10%/-0%*+10%/-0%* MECHANICAL SPECIFICATIONS Model VBHN330SA16, VBHN325SA16 Internal Bypass Diodes 4 Bypass Diodes Module Area 18.02 Ft.² (1.67m²) Weight 40.81 Lbs. (18.5kg) Dimensions LxWxH 62.6x41.5x1.4 in. (1590x1053x35 mm) Cable Length +Male/-Female 40.2/40.2 in. (1020/1020 mm) Cable Size / Type No. 12 AWG / PV Cable Connector Type2 Multi-Contact® Type IV (MC4™) Static Wind / Snow Load 50 PSF (2400 Pa) Pallet Dimensions LxWxH 63.7x42.2x65.4 in. Quantity per Pallet / Pallet Weight 40 pcs. /1719 Lbs. (780 kg) Quantity per 40' Container 560 pcs. Quantity per 20' Container 240 pcs. OPERATING CONDITIONS & SAFETY RATINGS Model VBHN330SA16, VBHN325SA16 Operating Temperature -40°F to 185°F (-40°C to 85°C) Hail Safety Impact Velocity 1" hailstone (25mm) at 52 mph (23m/s) Safety & Rating Certifications UL 1703, cUL, CEC UL 1703 Fire Classification Type 2 Limited Warranty 25** Yrs Workmanship and Power Output (Linear)*** DIMENSIONS 41.5[1053]1.38[35]20.3[516.5]4.41[112]1.48[37.5]31.3[795]62.6[1590]40.2[1020]5.47[139] 7.97[202.5]1.48[37.5]1.378[35]1.378[35]0.059[1.5]0.118[3]0.994[25.25] 1.457[37]1.260[32] 0.797[20.25] 39.7[1009] Mount Locations 41.5[1053]1.38[35]20.3[516.5]4.41[112]1.48[37.5]31.3[795]62.6[1590]40.2[1020]5.47[139] 7.97[202.5]1.48[37.5]1.378[35]1.378[35]0.059[1.5]0.118[3]0.994[25.25] 1.457[37]1.260[32] 0.797[20.25] 39.7[1009] Mount Locations Unit: inches (mm) NOTE: Standard Test Conditions: Air mass 1.5; irradiance = 1000W/m²; cell temp. 25°C * Maximum power at delivery. For guarantee conditions, please check our guarantee document. ** Installation need to be registered through our website www.panasonicusahitwarranty.com within 60 days in order to receive twenty-five (25) year Product workmanship. Otherwise, Product Workmanship will be only fifteen (15) years. *** 1st year 97%, after 2nd year 0.26% annual degradation to year 25. 1 STC: Cell temp. 25°C, AM1.5, 1000W/m² 2 Safety locking clip (PV-SSH4) is not supplied with the module. NOTE: Specifications and information above may change without notice. INVERTERSwww.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology -3 -3 --- 3 3 3 3 3 3 3 ----- Yes W ----- Yes ----- Yes W Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. TESLA.COM/ENERGY POWERWALL Tesla Powerwall is a fully-integrated AC battery system for residential or light commercial use. Its rechargeable lithium-ion battery pack provides energy storage for solar self-consumption, time-based control, and backup. Powerwall’s electrical interface provides a simple connection to any home or building. Its revolutionary compact design achieves market-leading energy density and is easy to install, enabling PERFORMANCE SPECIFICATIONS AC Voltage (Nominal)120/240 V Feed-In Type Split Phase Grid Frequency 60 Hz Total Energy 14 kWh Usable Energy 13.5 kWh Real Power, max continuous 5 kW (charge and discharge) Real Power, peak (10s, off-grid/backup)7 kW (charge and discharge) Apparent Power, max continuous 5.8 kVA (charge and discharge) Apparent Power, peak (10s, off-grid/backup)7.2 kVA (charge and discharge) Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Overcurrent Protection Device 30 A Imbalance for Split-Phase Loads 100% Power Factor Output Range +/– 1.0 adjustable Power Factor Range (full-rated power)+/– 0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency1,3 90% Warranty 10 years ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F) Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R Ingress Rating IP67 (Battery & Power Electronics) IP56 (Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m < 40 dBA at 30°C (86°F) MECHANICAL SPECIFICATIONS Dimensions1 1150 mm x 755 mm x 147 mm (45.3 in x 29.6 in x 5.75 in) Weight1 114 kg (251.3 lbs) Mounting options Floor or wall mount 1 Dimensions and weight differ slightly if manufactured before March 2019. 1 Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2 In Backup mode, grid charge power is limited to 3.3 kW. 3 AC to battery to AC, at beginning of life. COMPLIANCE INFORMATION Certifications UL 1642, UL 1741, UL 1973, UL 9540, IEEE 1547, UN 38.3 Grid Connection Worldwide Compatibility Emissions FCC Part 15 Class B, ICES 003 Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) 2 4 6 5 3 8 1 7 753 mm (29.6 in) 147 mm (5.75 in) 1150 mm (45.3 in) Contact Tesla for additional information. General Terms and Conditions of Installation The relationship between Jefferson Electric, LLC (“Contractor”) and “Customer” shall be based on the General Terms and Conditions of Sale, as defined below: 1.Turn Key Service: Contractor is providing a "turn-key" system which includes all applicable standard hardware, materials, and supplies required to provide a fully-operational photovoltaic system as described in Proposal and Project Summary attached hereto. Contractor shall provide proper bonding and grounding and properly waterproof all penetrations. 2.Compliance to Building Codes: All work shall be completed in a workmanship like manner and in compliance with all building codes and other applicable laws. 3.License Status: To the extent required by law all work shall be performed by individuals duly licensed and authorized by law to perform said work. 4.Use of Subcontractors: Contractor may at its discretion engage subcontractors to perform work hereunder, provided Contractor shall fully pay said subcontractor and in all instances remain responsible for the proper completion of this Contract. 5.Change Order (Mid-Performance Amendments): The Contractor and Customer recognize that Contractor`s original cost and time estimates may need to be adjusted due to unforeseen events, or to factors unknown to the Contractor when the contract was made; Customer may desire a mid-job change in the specifications that would add time and cost to the specified work possibly inconvenience the Contractor; or Other provisions of the contract may be difficult to carry out because of unforeseen events, such as a materials availability and pricing, shipping delays, labor strikes. If these or other events beyond the control of the parties reasonable require adjustments to this contract, the parties shall make a good faith attempt to agree on all necessary particulars. Such agreements shall be put in writing, signed by the parties and added to this contract. Failure to reach agreement shall be deemed a dispute to be resolved as agreed herein. 6.Liability Waiver: Contractor warrants it is adequately insured for injury to its employees and others incurring loss or injury as a result of the acts of Contractor or its employees and subcontractors. 7.Permits and Approvals: Contractor shall at its own expense obtain a permit for the work to be performed. 8.Additional Costs: Any alterations and additional costs required or recommended by the local utility to ensure safe and proper interconnection shall be the responsibility of the Customer. Additional costs to the customer may include, but are not limited to: requested customer upgrades, roof repairs, ground trenching, landscaping, electrical panel upgrades, sub-panel installations, and extended conduit runs. 9.Governing Law: This Agreement and any disputes shall be governed in accordance with the laws of the State of Indiana. 10.Force Majeure: Contractor shall not be liable for any delay due to circumstances beyond its control including strikes, casualty or general unavailability of materials. Any starting or completion dates stated by us shall be subject to clarification of all technical details. Moreover, Contractor’s obligation to meet any deadlines shall be based on the punctual and proper fulfillment of the customer`s, utility’s, and local government’s obligations. In the event of strikes, lockouts, Force Majeure, delayed shipments by suppliers or subcontractors or other causes hindering punctual Completion for reasons that Contractor is not accountable for, Contractor shall be entitled to extend the estimated completion date by a reasonable amount of time. 11.Materials: All materials shall be new, in compliance with all applicable laws and codes, and shall be covered by a manufacturer's warranty if appropriate. 12.What Constitutes Completion: The work specified herein shall be considered completed upon approval by Customer, provided that Customer's approval shall not be unreasonably withheld. Substantial performance of the specified work in a workmanlike manner shall be considered sufficient grounds for Contractor to require final payment by Customer. Any delays caused by the local utility, any authorities having jurisdiction, or SREC related entities shall not be grounds for the customer to withhold final payment. 13.Warranties: See Workmanship Warranty [attached] 14.Payment: Customer signature and 50% deposit is required to begin the installation and interconnection process. Payment of 45% (95% of total) is due immediately upon completion of Contractor’s installation of solar equipment and receipt of invoice. Remaining 5% is due upon utility interconnection approval. A 2.5% surcharge is applied to credit card payments. Workmanship Warranty Jefferson Electric LLC (“Jefferson Electric”) offers a limited warranty (“Workmanship Warranty”) for any defects in the workmanship carried out by its qualified installers when installing a solar energy system (“SES”). Beneficiary of this Workmanship Warranty This warranty applies to the customer named in the solar array installation agreement entered into with Jefferson Electric. Where the installation premises has been transferred, Jefferson Electric will transfer this Workmanship Warranty to the new owner of the premises for the balance of the warranty period on the same terms. Scope of this Workmanship Warranty The Workmanship Warranty covers any defects that arise from the workmanship at the premises specified in the solar array installation agreement. The Workmanship Warranty does not cover any of its components, which may be covered by separate manufacturer warranties. The Workmanship Warranty period is 16 years from the date of the signed agreement. Where the Workmanship Warranty applies, Jefferson Electric will, at its discretion and cost, rework or repair the SES. Comparable parts shall be new or refurbished in order to restore the SES. Limitations and Exclusions of the Workmanship Warranty: To the extent permitted by law, claims are excluded from the Workmanship Warranty where the defect or loss is or has been caused or contributed by: ◾improper use of the solar SES; ◾failure to comply with manufacturer instructions; ◾work performed on the SES (including modifying, moving or relocating any part of the system, even if temporarily) by anyone other than Jefferson Electric; ◾non-adherence to maintenance requirements set out by Jefferson Electric or component manufacturers; ◾any act, omission, misuse, abuse, or damage (whether wilful, accidental or negligent) caused by the customer or a third party; ◾any extreme weather at the location in which the array was installed (lightening, floods, power surges, animal or insect damage, corrosion, land or building movement); ◾interference from other devices or site modification; ◾general wear and tear; ◾events outside of design specifications caused by the utility, distributor or network operator; ◾failure to promptly notify Jefferson Electric of any system defects or adverse conditions; ◾any work or parts which were not part of the installation agreement. You must provide all reasonable assistance, including remote site monitoring, to Jefferson Electric to help us diagnose and remedy any defects. If you do not do so, costs to attend your premises may not be covered by the Workmanship Warranty. Any repairs excluded under the Workmanship Warranty may and shall be completed using current labor and material rates. Claims under this Workmanship Warranty To claim under this Workmanship Warranty, please contact Jefferson Electric by one of the following means: 2114 East Washington Street, Indianapolis, Indiana 46201 Support@JeffersonElectricLLC.com (317)624-2795 You will need to provide: Your name, address and contact telephone number; Outline of the nature of the defect; Evidence of the defect. This Workmanship Warranty replaces and supersedes any and all previous warranties or guarantees from Jefferson Electric, both written and verbal. This Workmanship Warranty is provided by Jefferson Electric LLC, as the entity that entered into the solar installation services agreement with you.