HomeMy WebLinkAboutLEGACY RIDGE 90 - LR090 (AS DESIGNED)IECC 2009 Performance Compliance
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90
LRO90 (AS DESIGNED)
LEGACY RIDGE 90
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,758
$281
$416
$2,455
$957
$0
$3,412
Requirements
C-M,
Energy Solutions
As Designed
51,767
S270
S416
$2,453
S957
so
$3,410
C4405.3 Performance-based compliance passes by 0.1%
R402.4.12 Air Leakage Testing Air sealing is 6.DD ACH at 5D Pa. It must not exceed 7 -DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 0.1%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
7111119 at 10:53 AM
Ekotrope RATER -Version 3.1.0.2212
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
1814 PULASKI CT
4Fri MI
CARMEL, IN 46033
Builder: LENNAR HOMES
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 6 ACH50
Window U -Value: 0.31, SHGC: 0.32
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 327 CFM @ 25Pa (61100 s.f.)
Total Duct Leakage 436.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 95.5 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 7111119 at 10:53 AM
Ekotrope RATER - Version 3.1.0.2212
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
1814 PULASKI CT TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90 Builder
LENNAR HOMES
LR090 (AS DESIGNED)
LEGACY RIDGE 90
General Building Information
Conditioned Area (sq ft) 5,454
Conditioned Volume (cubic ft) 51,120
Insulated Shell Area (sq ft) 9,401
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT(1,872 s.f., 1i ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: OVER GAR (70 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
[ Name: CONDIAMB (Exterior Perimeter [ft]: 168, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 31, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 7)
R: 11.00
Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4
Above Grade Wall
El Name: CONDIAMB (2,397 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (468 s.f.)
R-3 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
1814 PULASKI CT TSI Energy Solutions
CARMEL, IN 46033 Matthew Timmons
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90 Builder
LENNAR HOMES
LR090 (AS DESIGNED)
LEGACY RIDGE 90
Name: CONDIGAR (279 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (248 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CONDIAMB (303 s.f.)
R: 13.575
Name: CONDIGAR (31 s.f.)
R: 10.876
Name: CONDIATTIC (31 s.f.)
R: 13.575
Roof
El Name: MAIN (1,942 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
El Name: FRONT (184 s.f.), U:0.310, SHGC: 0.29, Orientation: EAST
El Name: BACK (228 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
C-M
Energy Solutions
Property Organization Inspection Status
1814 PULASKI CT TSI Energy Solutions Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90 Builder
LENNAR HOMES
LR090 (AS DESIGNED)
LEGACY RIDGE 90
E] Name: BACK BSMT (11 s.f.), U:0.320, SHGC: 0.31, Orientation: WEST
E] Name: SLIDER (40 s.f.), U:0.290, SHGC: 0.33, Orientation: WEST
El !Name: RIGHT SIDE (52 s.f.), U:0.310, SHGC: 0.32, Orientation: NORTH
El Name: LEFT SIDE (106 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
0 Fuel -fired air distribution (1) • Natural Gas • 100% Heating Load @ 95.5 AFUE
Air conditioner (2) • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating (3) • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 5,112 CFM50 (6.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
3
Energy Code Inspection Checklist
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90
LR090 (AS DESIGNED)
LEGACY RIDGE 90
Duct Leakage
Duct System 1
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 327 CFM @ 25 Pa (6 f 100 s.f.)
Total Duct Leakage specified as 436.0 CFM @ 25Pa (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
Organization Inspection Status
1814 PULASKI CT
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Matthew Timmons
Model: SOUTHILL (B)
Depth Below Grade Perimeter
Community: LEGACY RIDGE
Builder
CONDIAMB R-11 Draped, 4Pt
LENNAR HOMES
LRO90 (AS DESIGNED
Exposed Exterior
LEGACY RIDGE 90
CONDIGAR R-11 Draped, 4Pt
General Building Information
7 31
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq_ ft.]
5;454
Unconditioned, attached garage?
Yes
Conditioned Volume [Cu. ft.]
51;120
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Top
Model
SOUTHILL (B)
Community
LEGACY RIDGE 90
Climate Zone
5A
C-M,
Energy Solutions
Foundation Wall
Name Library Type
Height Above Grade
Depth Below Grade Perimeter
Location
Enclosing
CONDIAMB R-11 Draped, 4Pt
1
8 168
Exposed Exterior
Conditioned Space
CONDIGAR R-11 Draped, 4Pt
1
7 31
Exposed Exterior
Conditioned Space
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top To
Is Fully Insulated Continuous R -value
Cavity R -value Effective Insulation R -
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-11 Draped_ Oft D
4
No N?A
NIA
11.00
Slab
Name Library Type
Perimeter Floor Grade
Carpet R Exposed Surface
Masonry Area
Area Location
Enclosing
BSMT Uninsulated
1 Below Grade 0 0 1,872.0 R2 Exposed Exterior
Conditioned
Space
Slab Library Lis
Name Wall Construction
Slab Completel Underslab Perimeter Perimeter
Thermal Break
Effective R -value
Type
Insulated. Insulation
Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Wood Frame/ Other
No
0 0 0
No
ID. DD
1
Building Summary
Property
Organization
1814 PULASKI CT
TSI Energy Solutions
CARMEL, IN 46033
Matthew Timmons
Model: SOUTHILL (B)
Surface Calor
Community: LEGACY RIDGE 90
Builder
CONDIAMB
LENNAR HOMES
LR090 (AS DESIGNED.
2.397.0 f['
LEGACY RIDGE 90
CONDIAMB 2X6
ramed Floor
Medium
Name Library Type
Ca
OVER GAR R-38, GR1
G1 R-13 BATT, R-3.0
Medium
248.0 Rs
Framed Floor Library List
Name
Effective R -value
R-38, GRi
2
33.825
Rim Joist
Name Library Type
CONDIAMB G1 R-13, R-3.0
CONDIATTIC G1 R-13, R-3.0
CONDIGAR G1 R-13, OSB
Rim Joist Library List
Name Effective Insulation R -value
G1 R-13, OSB 10.876
G1 R-13. R-3.0 13.575
C-M
Energy Solutions
Inspection Status
Results are projected
e Surface Area Location
1.23 Above Grade 70.0 R2 Unconditioned, attached
garage
303.0 fF Exposed Exterior
31.fl fF Attic
31.fl fF Unconditioned, attached garage
ali
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
G1 R-13 BATT, R-3.0
Medium
2.397.0 f['
Exposed Exterior
CONDIAMB 2X6
G1 R-19, R-3.0 2X6
Medium
468.0 f['
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R-3.0
Medium
248.0 Rs
Attic
2
Building Summary
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90
LRO90 (AS DESIGNED)
LEGACY RIDGE 90
Name
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Library Type
Inspection Status
Results are projected
Surface Calor
Surface Area
C-MEnergy Solutions
Location
CONDIGAR G1 R-13 Gar Walls
Medium
279.0 fts
Unconditioned, attached garage
Wall Library List
Name
Effective R -value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
G1 R-19, R-3.0 2X6
20217
Glazing
Name Library Type Wall
Assignment Foundation Wall
Assignment
Overhang Depth Overhang Ft
Top
To Overhang Ft To
Bottom
Orientation
Surface Area
BACK U-.31, SHGG.32
CONDIAMB
0
0 0
West
228.0 R2
BACK BSMT U-.32, SHGC-.31
CONDIAMB
0
0 0
West
11.0 ft`
FRONT U-.31, SHGG29
CONDIAMB
0
0 ❑
East
184.0 fts
LEFT SIDE U-.31, SHGG.32
CONDIAMB
0
0 ❑
South
106.0 fts
RIGHT SIDE U-.31, SHGG.32
CONDIAMB
0
0 ❑
North
52.0 ft
SLIDER U-29, SHGG.33
CONDIAMB
0
0 ❑
West
40.0 f'
Glazing Library List
Name
Shg c
U factor
U-29, SHGC-.33
0.33
0290
U-.31, SHGC-29
029
0.310
U-.31, SHGC-.32
0.32
0.310
U-.32, SHGC-.31
0.31
0.320
Building Summary
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90
LRO90 (AS DESIGNED)
LEGACY RIDGE 90
kylight
Skylight Library List
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
�.A
FM
0
Name
Library Type Wall Assignment Foundation Wall
Emittance Solar Surface Color
Surface Area Location
Assignment
Ab sorpta nce
FRONT
Steel Door CONDIAMB
0.9 0.75 Medium
20.0 T Exposed Exterior
GARAGE
Steel Door CONDIGAR
0.9 0.75 Medium
18.0 f' Exposed Exterior
Opaque Door Library List
Name Effective U -factor
0.182
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location
P.f.] Tiles
MAIN R-38 Blown, GR1 7,942 No Medium 1.942.0 f[s Attic
Roof Insulation Library List
Name Has Radiant Barrier Effective R -value
'•0 �- -I :a l No 38268
4
Building Summary
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RI DG
LRO90 (AS DESIGNED
LEGACY RIDGE 90
FWhole House Infiltration
Infiltration
6 ACH at 50 Pa
Mechanical Ventilation
Lighting ,
°I Interior Fitiorescent
Lighting
Onsite Generation
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Blower -door tested 4
rang Y. t)senor rmorescem
Lighting
100 0
None Present
Onsite Generation Library List
None Present
Solar Generation
Solar Generation Library List
C-M,
Energy Solutions
Lighting
1❑0
Building Summary
Property Organization Inspection Status
1814 PULASKI CT TSI Energy Solutions Results are projected
CARMEL, IN 46033 Matthew Timmons
Model: SOUTHILL (B)
Community: LEGACY RI DG Builder
LENNAR HOMES
LRO90 (AS DESIGNED
LEGACY RIDGE 90
onditioning Equipment
Name Library Type Pleating Percent Load Cooling Percent Load
Air conditioner (2) CA13NA042 0% 100%
I Fuel -fired air 915SA48080S17 100% o%
distribution (1)
IWater Heating (3) RE350` 0% o%
1
Equipment Type: 915SA4808OS17 MJFM=Wu
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5 AFUE
Heating Capacity [kBtulh]
78
Use default EAE
No
EAE [kWh]
946
Equipment Type: CA13NA042
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
46
Equipment Type: RE350*
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
C-M,
Energy Solutions
r Percent Load Location
0 Conditioned Space
❑ I Conditioned Space
1001 Conditioned Space
61
Building Summary
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RIDGE
LRO90 (AS DESIGNED.
LEGACY RIDGE 90
1butivn System
tion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
)uct R Value
Xct Area r]
]uct Area [ff]
5 to Outdoors
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Ctm Per Watt
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Forced Air
Fuel -fired air distribution (1)
Air conditioner (2)
5454
6
30
30
1041.7
964.5
327 CFM @ 25Pa (61 100 s-1)
436
Post -Construction
Yes
Conditioned Space
70
70
Attic (well vented; under insulation)
30
30
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
C-M,
Energy Solutions
7
Building Summary
Property
1814 PULASKI CT
CARMEL, IN 46033
Model: SOUTHILL (B)
Community: LEGACY RIDGE 90
LRO90 (AS DESIGNE-D:
LEGACY RIDGE 90
ater Distribution
I
ter Fixture Type
e Default Hot Water Pipe Length
t Water Pipe Length [ft]
Least R3 Pipe Insulation?
t Water Recirculation System?
circulation System Pipe Loop Length [ft]
in Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Standard
No
134
No
No
30
No
Electric
Timer Controls
glow
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.847
❑.331
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�