Loading...
HomeMy WebLinkAboutE-0011 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\050_201919032_E-001.dwg June 19, 2019 - ecurryE-001ELECTRICAL DETAILSMAR LT 1. ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (N.E.C.) AND APPLICABLE CODES, ORDINANCES, RULES, REGULATIONS, AND LAWS OF ALL LOCAL, MUNICIPAL, OR STATE AUTHORITIES HAVING JURISDICTION. 2. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING OR EFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE PROGRESS OF ALL WORK UNDER THIS CONTRACT. 3. ALL OUTLETS AND SWITCHES SHALL BE AS SPECIFIED IN SPECIFICATION SECTION 262726. 4. MOUNT RECEPTACLES WITH THE LONG AXIS VERTICAL EXCEPT WHERE SPECIFICALLY NOTED ON THE PLANS TO BE MOUNTED WITH THE LONG AXIS HORIZONTAL. 5. ALL RECEPTACLES SHALL BE WIRED USING 2#12 & 1#12(G). MINIMUM CONDUIT SIZE (WHERE UTILIZED) SHALL BE 3/4". REFER TO SPECIFCATION SECTION 16110 FOR ALLOWABLE USES FOR MC CABLE. NUMERAL INDICATES CIRCUIT NUMBER. 6. SEE ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL DATA/POWER RECEPTACLES AND LIGHTING. 7. ALL PENETRATIONS OF WALLS, PARTITIONS, CHASES, SHAFTS, FLOORS, AND ROOF SHALL BE COMPLETELY SEALED. PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED TO PROVIDE A FIRE RATING EQUAL TO OR GREATER THAN THAT OF THE WALL OR FLOOR PENETRATED. 8. E.C. SHALL PROVIDE TYPEWRITTEN DIRECTORIES FOR ALL PANELS. PANEL DIRECTORIES SHALL INCLUDE MONTH AND YEAR IN LOWER RIGHT CORNER. 9. E.C. SHALL PROVIDE OWNER WITH COMPLETE AND ACCURATE 'RECORD' DOCUMENTS FOR THE WORK PROVIDED/INSTALLED. 10. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND THESE SPECIFICATIONS HEREIN. WORK INCLUDES THE FOLLOWING UNDERSTANDINGS. a.CONTRACT DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO OUTLINE BASIC ENGINEERING AND SYSTEMS DESIGN, THEREFORE DO NOT SHOW DETAILS AND ACCESSORIES. IT IS THE CONTRACTOR'S RESPONSIBILITY FOR FURNISHING AND INSTALLING ALL SUCH ITEMS NECESSARY TO PROVIDE COMPLETE, OPERATIVE AND PROPERLY INSTALLED SYSTEMS TO THE OWNER. THE CONTRACTOR SHALL BE REQUIRED TO OBTAIN A WRITTEN RESPONSE FROM THE ENGINEER PRIOR TO BID FOR ANY DOCUMENT CLARIFICATION. b.THE DRAWINGS SHOW THE INTENDED LOCATION OF THE EQUIPMENT, HOWEVER, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY MINOR ADJUSTMENTS OR RELOCATIONS NECESSARY DUE TO CHOICE OF EQUIPMENT AND COORDINATION CONFLICTS. ALL EQUIPMENT RELOCATIONS MUST BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR APPROVAL. c.THE PROJECT CONTRACT DRAWINGS, SPECIFICATION, AND OTHER RELATED DOCUMENTS ARE COMPLIMENTARY. ITEMS REQUIRED BY ONE SHALL DESIGNATE REQUIREMENT BY THE OTHER, WHETHER EXPLICITLY STATED OR NOT. WHERE DOCUMENTS CONFLICT, THE WORK OF THE MORE STRINGENT NATURE SHALL BE REQUIRED. d.THE CONTRACTOR SHALL PROVIDE ALL NECESSARY ASSOCIATED ELECTRICAL EQUIPMENT, DISCONNECTS, STARTERS, WIRE, CONDUIT ETC. FOR ALL MECHANICAL/PLUMBING SYSTEMS. REFER TO MECHANICAL/ PLUMBING PLANS FOR SCOPE OF WORK. e.THE CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY ASSOCIATED EQUIPMENT FOR A COMPLETE AND OPERATIONAL SECURITY/ CCTV SYSTEM. 11. CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE PREMISES IN ORDER TO BE FAMILIAR WITH THE EXISTING CONDITIONS WHICH MAY IN ANY WAY AFFECT THE INSTALLATION OF THE WORK SPECIFIED HEREIN. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR THE CONTRACTORS FAILURE TO COMPLY HEREIN. 12. PROCURE AND PAY ALL PERMITS AND LICENSES REQUIRED FOR WORK UNDER THIS SECTION. 13. ALL EQUIPMENT AND MATERIALS INSTALLED ON THIS PROJECT AS WELL AS THE COMPLETE ELECTRICAL INSTALLATION SHALL COMPLY WITH ALL THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) WHEREVER THEY APPLY. 14. ELECTRICAL CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR LAYING OUT HIS WORK AND FOR ANY DAMAGE CAUSED TO THE OWNER OR OTHER CONTRACTORS BY IMPROPER LOCATION OR CARRYING OUT HIS WORK. 15. ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES AND IN SUCH MANNER AS TO NOT INTERFERE WITH OTHER WORK. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES IN ORDER TO HAVE ALL PIPES, CONDUITS, ETC., INSTALLED ON THE DRAWINGS AND SPECIFICATIONS. 16. THE WORK INCLUDES THE FURNISHING OF MATERIALS, TOOLS, EQUIPMENT, TRANSPORTATION SERVICES, SCAFFOLDING, SUPERVISION, LABOR, AND OTHER ITEMS WHICH MAY NOT BE MENTIONED, BUT ARE NECESSARY FOR THE FABRICATION, INSTALLATION, OR APPLICATION AND COMPLETION OF THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND SPECIFICATIONS. 17. CONDUCTORS #4 AWG AND SMALLER SHALL BE TYPE THWN/THHN. CONDUCTORS LARGER THAN #4 AWG SHALL BE TYPE XHHW, ALL RATED 600 VOLTS, COPPER CONDUCTORS. ALL CONDUCTORS SHALL BE STRANDED COPPER, WHERE AVAILABLE. ALL CONDUIT SHALL BE EMT 3/4" MINIMUM UNLESS OTHERWISE NOTED. 18. MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG FOR POWER AND #14 AWG STRANDED FOR CONTROL. 19. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES IN THE FIELD. 20. CONTRACTOR SHALL FOLLOW OWNER'S SAFETY RULES AND SHALL BROOM CLEAN DAILY. ALL DEBRIS SHALL BE REMOVED FROM THE BUILDING AND GROUNDS. 21. NO COMBUSTIBLE MATERIALS WILL BE PERMITTED IN CEILING PLENUMS. 22. ALL RECEPTACLES TO BE INSTALLED BY ELECTRICAL CONTRACTOR SHALL BE INSTALLED AT +18" A.F.F. UNLESS OTHERWISE SPECIFIED ON PLANS. 23. ALL EXPOSED CABLES INSTALLED IN AIR PLENUM CEILINGS SHALL HAVE PLENUM RATED INSULATION. IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO COORDINATE WITH OTHER TRADES TO VERIFY THAT ANY CABLES INSTALLED IN AIR PLENUM CEILINGS BY THOSE TRADES IS RATED FOR USE IN PLENUM CEILINGS. 24. ALL LIGHTING FIXTURES SHALL BE WIRED USING 2#12 & 1#12(G). MINIMUM CONDUIT SIZE (WHERE UTILIZED) SHALL BE 3/4". REFER TO SPECIFICATION SECTION 260210.00 FOP ALLOWABLE USES FOR MC CABLE. 25. GROUNDING OF THE NON-CURRENT CARRYING METALLIC PARTS OF ALL ELECTRICAL EQUIPMENT AND ENCLOSURES INCLUDING CONDUITS, SUPPORTS, CABINETS, TRANSFORMERS, MOTOR FRAMES. SWITCHGEAR ENCLOSURES, CONTROL PANELS, ETC. WHICH ARE INSTALLED OR CONNECTED UNDER THIS CONTRACT, SHALL BE PROPERLY CONNECTED TO THE GROUNDING SYSTEM PER N.E.C. ARTICLE 250, REGARDLESS OF WHETHER OR NOT THESE CONNECTIONS ARE SHOWN ON THE DRAWINGS. 26. ELECTRICAL CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY TO ACQUIRE THE LATEST AND CURRENT SET OF CONSTRUCTION DOCUMENTS. THESE DOCUMENTS TO INCLUDE ALL GENERAL BULLETINS AND BULLETINS ADDRESSING SPECIFIC CHANGES TO THE PROJECT. 27. VERIFY EXISTING GROUND IS COMPLIANT WITH NEC & LOCAL JURISDICTION. INFORM CONSTRUCTION MANAGER AND ENGINEER OF ANY ISSUES. 28. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY, DETERMINE ARC FAULT, AND PROVIDE LABELS PER N.E.C. PROJECT GENERAL NOTES SYMBOLS AND ABBREVIATIONS LIST NOTES: T X/Y/Z S M WP DUPLEX RECEPTACLE GROUND FAULT DUPLEX RECEPTACLE GROUND FAULT INTERRUPTER TYPE. INSTALL IN TELECOMMUNICATIONS INTERRUPTER TYPE WEATHERPROOF HOUSING G G LINE VOLTAGE VACANCY SENSOR SWITCH DUPLEX RECEPTACLE RECEPTACLES VSS NEW PANELBOARD - SURFACE DISCONNECT SWITCH. 'X' INDICATES SWITCH SIZE. 'Y' INDICATES NUMBER OF POLES. 'Z' INDICATES FUSE SIZE (NF = NON-FUSED) MOTOR STARTING SWITCH MOTOR M TRANSFORMER JUNCTION BOX IG DENOTATIONS & ABBREVIATIONS C AFF A E D CU G FF UT UE NTS V WP W AUDIO/VISUAL TV S2 VC POWER PHOTOCELLPC SINGLE POLE SWITCHS LIGHTING TELEVISION OUTLET WITH 3/4" RACEWAY AND WIRE BACK TO SPEAKER - WALL MOUNTED SPEAKER - CEILING MOUNTED VOLUME CONTROL TERMINATION AREA GROUND FAULT INTERRUPTER UNDERGROUND TELEPHONE WEATHERPROOF WALL MOUNTED VOLTS ISOLATED GROUND NOT TO SCALE UNDERGROUND ELECTRIC DOUBLE DEVICE EMERGENCY FLUSH FLOOR MOUNTED CONDUIT COPPER ABOVE FINISHED FLOOR AMPERE S1 ALL BULLETINS) PRIOR TO STARTING CONSTRUCTION. SET OF CONSTRUCTION DOCUMENTS (INCLUDING ELECTRICAL CONTRACTOR TO CONTACT GENERAL CONTRACTOR FOR VERIFICATION OF THE LATEST SOME OF THESE SYMBOLS MAY NOT BE USED UNDER THIS PROJECT. SEE THE CONTRACTOR NOTES FOR ADDITIONAL REQUIREMENTS. MISCELLANEOUS #12 AWG BRANCH CIRCUIT WIRING WITH 3/4" BRANCH CIRCUIT WIRING - #10 AWG IN 3/4" CONDUIT BRANCH CIRCUIT WIRING IN 1" CONDUIT - UNDER FLOOR CONDUIT CONCEALED IN WALLS OR ABOVE CEILING HOME RUN BACK TO PANEL CONDUIT TURNED DOWN CONDUIT TURNED UP EWC ELECTRIC WATER COOLER DOWNLIGHT WITH EMERGENCY BATTERY BALLAST EDGE LIT EXIT SIGN - DIRECTIONAL WALL MOUNTED LIGHT FIXTURE ARROWS AS INDICATED ON DRAWINGS LIGHTING FIXTURE - SEE FIXTURE SCHEDULE FOR MORE INFORMATION SEE FIXTURE SCHEDULE FOR MORE EMERGENCY LIGHTING FIXTURE WITH EMERGENCY BATTERY BALLAST - INFORMATION DOWNLIGHT ('D' - DENOTES DOUBLE FACED) DOUBLE DUPLEX RECEPTACLE DOOR CHIMEB INFORMATION OUTLET. OUTLET SHALL HAVE 4 PAIR, CATEGORY 6A PLENUM CABLE(S), QUANTITY AS SHOWN, TERMINATED ON THE DATA PATCH PANELS IN THE DATA RACK BY VENDOR. REFER TO SPECIFICATION SECTION 270500 FOR INSULATION COLORS. J FIRE RATED POKE-THRU ATM STACK EXT CCTV CAMERA IN ENVIRONMENTAL ENCLOSURE TO VIEW DRIVE UP STACKING FURNISH AND INSTALL TYPE "N" AND "G" CABLES TO THE DVR CONTROL IN THE MDF. ATM CAMERA ON ATM VENDOR SUPPLIED MOUNT FURNISH AND INSTALL TYPE "N" AND "G" CABLES TO THE DVR CONTROL IN THE MDF. CCTV CAMERA IN A DOME HOUSING FURNISH AND INSTALL TYPE "N" AND "G" CABLES TO THE DVR CONTROL IN THE MDF. CCTV CAMERA IN ENVIRONMENTAL ENCLOSURE WITH LENS. FURNISH AND INSTALL TYPE "N" AND "G" CABLES TO THE DVR CONTROL IN THE MDF. INTERIOR CCTV CAMERA WITH 2.8-12 mm LENS ON A STICK MOUNT. FURNISH AND INSTALL TYPE "N" AND "G" CABLES TO THE DVR CONTROL IN THE MDF. SAFE ALARM IR DC BACK-UP ALARM ATM ALARM ATM ALARM. FURNISH AND INSTALL 18 GAUGE, 8 CONDUCTOR, STRANDED CABLE. CABLE SHALL BE RUN IN A 3/4" CONDUIT FROM THE ATM TO THE ALARM CONTROL PANEL (TYPE "H" CABLE). DMP ALARM CONTROL. 120 VAC CIRCUIT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. PRESIDER SHALL BE MOUNTED IN THE TELECOMMUNICATIONS RACK. FIELD VERIFY EXACT LOCATION WITH THE OWNER. BACK-UP ALARM. CELLULAR BACK-UP SYSTEM DEPENDING ON SITE AVAILABILITY. 120 VAC CIRCUIT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. FIELD VERIFY EXACT LOCATION WITH THE OWNER. DIGITAL VIDEO RECORDER. DVR SHALL BE MOUNTED IN PNC SUPPLIED TELECOMMUNICATIONS RACK UNLESS OTHERWISE NOTED. HEIGHT CCTV CAMERA HEIGHT STRIP MOUNTED IN MULLION FURNISH AND INSTALL TYPE "N" AND "G" CABLES TO THE DVR CONTROL IN THE MDF. CAMERA POWER SUPPLYPS VIDEO MONITOR REQUIRES A RG 59U COAXIAL CABLE TO THE DVR CONTROL AND A 120 VAC CIRCUIT PROVIDED BY ELECTRICAL CONTRACTOR (SEE E-101). HOLD UP BUTTON. FURNISH AND INSTALL 22 GAUGE, 4 CONDUCTOR, STRANDED CABLE (TYPE "C" CABLE). MONEY CLIP. FURNISH AND INSTALL 22 GAUGE, 4 CONDUCTOR, STRANDED CABLE (TYPE "C" CABLE). HOLD UP INDICATOR. FURNISH AND INSTALL 22 GAUGE, 8 CONDUCTOR, STRANDED CABLE (TYPE "D" CABLE). MOTION SENSOR, CORNER OR CEILING MOUNT, FURNISH AND INSTALL 22 GAUGE, 4 CONDUCTOR, STRANDED CABLE (TYPE "C" CABLE). SAFE ALARM. FURNISH AND INSTALL 18 GAUGE, 8 CONDUCTOR, STRANDED CABLE. CABLE SHALL BE RUN IN A 3/4" CONDUIT FROM THE SAFE TO THE ALARM CONTROL PANEL (TYPE "H" CABLE). ALARM KEYPAD. FURNISH AND INSTALL (2) 22 GAUGE, 8 CONDUCTOR, STRANDED CABLES (TYPE "D" CABLE). DOR CONTACT. FURNISH AND INSTALL 22 GAUGE, 4 CONDUCTOR, STRANDED CABLE (TYPE "C" CABLE). CABLING SHALL BE RUN IN WINDOW MULLIONS AND FRAMING DURING CONSTRUCTION TO ENSURE ACCESS. VIDEO MONITOR. REQUIRES (2) RG 59U COAXIAL CABLES TO THE DVR CONTROL AND A 120 VAC CIRCUIT PROVIDED BY PNC BANK ELECTRICAL CONTRACTOR. STK ELECTRIC DOOR CONTROL MAGNETIC LOCK. FURNISHED WITH DOOR HARDWARE, INSTALLED AND WIRED BY E.C. TO ATM VESTIBULE DOOR ACCESS CONTROL PANEL. WIRING PER CONTROL PANEL MANUFACTURER'S REQUIREMENTS. ATM VESTIBULE CARD READER. FURNISHED WITH DOOR ACCESS CONTROL PANEL AND INSTALLED & WIRED BY E.C. WIRING PER CONTROL PANEL MANUFACTURER'S REQUIREMENTS.CR EXT IP Axis IPHEIGHT Anixter IP CAMERAS. FURNISH AND INSTALL "CAT6A" CABLES TO THE DVR CONTROL IN THE MDF. IR (NOTE: ALL SYMBOLS MAY NOT BE USED) SECURITY CABLE TYPE DESCRIPTION CABLE PART # C D H G N BELDEN 6502UE BELDEN 6506UE BELDEN 6306UE BELDEN 6300UE 4 CONDUCTOR #22 GAUGE, STRANDED CABLE IN 3/4" CONDUIT 8 CONDUCTOR #22 GAUGE, STRANDED CABLE IN 3/4" CONDUIT 8 CONDUCTOR #18 GAUGE, STRANDED CABLE IN 3/4" CONDUIT 2 CONDUCTOR #18 GAUGE, STRANDED, TWISTED PAIR CABLE* IN 3/4" CONDUIT RG-59 COAXIAL CABLE* IN 3/4"C. *NOTE: COMBINATION COAX AND POWER CABLE MAY BE USED TO REPLACE "N" AND "G" TYPE CABLES NOTE: CABLES SHOWN HERE ARE FOR BIDDING PURPOSES ONLY. E.C. SHALL VERIFY EXACT CABLING REQUIREMENTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. SECURITY CABLING SCHEDULE LUTRON LIGHTING CONTROLS LPP PW SQS SLINE VOLTAGE TIME SWITCHTS ESN VS DS LUTRON "PowPak" DIMMING MODULE. REFER TO DETAIL 2/E-603 FOR WIRING. MOUNT ABOVE ACCESSIBLE CEILING WHERE SHOWN ON E-111. LUTRON "Energi Savr Node" MODULE. REFER TO DETAIL 1/E-603 FOR WIRING. MOUNT WHERE SHOWN ON E-111. LUTRON "PICO" WIRELESS WALL SWITCH. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. LUTRON MULTI-BUTTON QSN SYSTEM WALL SWITCH. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. LUTRON WIRELESS VACANCY SENSOR. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. LUTRON WIRELESS DAYLIGHT SENSOR. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. QS LUTRON 'QS' SENSOR MODULE. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. 1. SYMBOLS ARE NOT SHOWN TO SCALE 2. ALL SYSMBOLS MAY NOT BE USED PWC SLUTRON "PICO" WIRED WALL SWITCH. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. IP DOME WIRELESS PENDANTSWP DS LUTRON WIRED DAYLIGHT SENSOR. REFER TO DETAIL 1/E-603 FOR ADDITIONAL INFORMATION. W TRIPLEX RECEPTACLE 06/20/2019 07/23/19 William Hohlt