Loading...
HomeMy WebLinkAboutE-5011 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\050_201919032_E-501.dwg June 19, 2019 - ecurryE-501ELECTRICAL SCHEDULES &ONE-LINE DIAGRAMMAR LT A. CONTRACTOR IS RESPONSIBLE FOR LOADING ON ALL PANELS AND FEEDERS PER THE N.E.C. CONTRACTOR SHALL KEEP CIRCUIT CONTINUITY TO DEVICES TO REMAIN. E.C. SHALL VERIFY THAT ALL LOADS PLACED ON EXISTING PANELS DO NOT EXCEED THE MAXIMUM LOADING REQUIREMENT PER THE LATEST EDITION OF THE NEC. NOTIFY A/E IF OVERLOAD IS POSSIBLE. PRIOR TO START OF WORK. LOADING NOTES 1. CONTRACTOR IS RESPONSIBLE FOR LOADING ON ALL PANELS AND FEEDERS PER THE N.E.C. CONTRACTOR SHALL KEEP CIRCUIT CONTINUITY TO DEVICES TO REMAIN. E.C. SHALL VERIFY THAT ALL LOADS PLACED ON EXISTING PANELS AND FEEDERS DO NOT EXCEED THE MAXIMUM LOADING REQUIREMENT PER THE LATEST EDITION OF THE NEC. NOTIFY A/E IF OVERLOAD IS POSSIBLE. 2. E.C. SHALL VERIFY THAT THE NEW LOADS DO NOT OVERLOAD EXISTING UTILITY SERVICE, THE CONTRACTOR IS ALSO RESPONSIBLE TO CALCULATE AND VERIFY THAT ALL UPSTREAM PANELS AND FEEDERS ARE NOT OVERLOADED DUE TO THE NEW LOADS. CONTRACTOR SHALL NOTIFY ENGINEER OF LOAD CALCULATIONS PRIOR TO COMMENCING WORK. 3. ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING SERVICE, PANELS, AND FEEDERS IN FIELD BEFORE START OF WORK, AND INFORM ENGINEER OF FINDINGS. PANEL SCHEDULE GENERAL NOTES: LIGHTING FIXTURE SCHEDULE NOTES 1. LIGHT FIXTURES ARE PNC FURNISHED THRU VILLA LIGHTING. REFER TO THE MATRIX OF RESPONSIBILITY ON TS-001. VILLA LIGHTING CONTACTS: MATT KAESTNER, 314-633-0456, matt.kaestner@villalighting.com OR, DAN PUELLMANN, 314-633-0472, dan.puellmann@villalighting.com. THE E.C. IS RESPONSIBLE FOR CONTACTING VILLA LIGHTING TO OBTAIN PRICING TO INCLUDE IN HIS BID. PNC WILL ORDER LIGHT FIXTURES. 2. E.C. SHALL PROVIDE VILLA LIGHTING WITH SHIPPING ADDRESS TO CONTRACTOR'S WAREHOUSE. LIGHT FIXTURES SHALL NOT BE SHIPPED DIRECTLY TO SITE. EXISTING METER EXISTING CT CABINET M TO EXISTING POWER Co. TRANSFORMER 1. THIS IS A FULLY RATED SYSTEM. MAIN BREAKER AND FEEDER BREAKERS IN SWITCHGEAR ARE BE RATED FOR 65,000 AMPS (MIN.) INTERRUPTING CURRENT (SYMMETRICAL). PROVIDE IDENTIFICATION LABELING FOR ALL FULLY RATED EQUIPMENT AS REQUIRED IN NEC 110.22 & 240.86. 2. THE E.C. SHALL COORDINATE WITH THE POWER Co. AND PROVIDE ARC-FLASH AND FAULT CURRENT CALCULATIONS AND LABELS ON ELECTRICAL EQUIPMENT PER NEC 110.16, NEC 110.24 AND LOCAL JURISDICTION REQUIREMENTS. 3. EXISTING SERVICE ENTRANCE GROUNDING TO REMAIN. E.C. SHALL VERIFY BONDING AND GROUND SYSTEM IS COMPLIANT WITH THE NEC. AND LOCAL JURISDICTIONS. INFORM CONSTRUCTION MANAGER WITH ANY ISSUES. 4. EXISTING FEEDERS TO REMAIN AS IS. UNLESS NOTED OTHERWISE. 5. E.C. SHALL INSPECT EXISTING CIRCUIT BREAKER SHOWN ON DRAWING TO BE REUSED AS SUFFICIENT FOR SERVICE. IF ANY IMPERFECTIONS ARE FOUND IN THE ENCLOSURE, REPAIR OR REPLACE AS REQUIRED. CIRCUIT BREAKER MUST RETAIN THEIR UL LISTING IN ACCORDANCE WITH NEC COMPLIANCE. 6. EXISTING GROUNDING TO REMAIN. EXISTING TO REMAIN LEGEND ONE-LINE DIAGRAM NOTES 1 PARTIAL EXISTING ONE-LINE DIAGRAM N.T.S. ONLY PANELS WITH ADDITIONAL NEW LOADS ARE SHOWN. BESIDES VERIFYING THAT THE NEW LOADS DO NOT OVERLOAD EXISTING PANELS, THE CONTRACTOR IS ALSO RESPONSIBLE TO CALCULATE AND VERIFY THAT ALL UPSTREAM PANELS AND FEEDERS ARE NOT OVERLOADED DUE TO THE NEW LOADS. EXIST. PANEL "E" 400A. MLO 277Y/480V, 3Ø, 4W 2 EXIST PANEL "F" 400A. MLO 277Y/480V, 3Ø, 4W 2 EXIST. 75 KVA TRANSFORMER 208Y/120V-3ɸ-4W SECONDARY 480V-3ɸ-3W PRIMARY 6 EXIST. PANEL "D" 225A. MCB 120Y/208V, 3Ø, 4W 2 EXIST. PANEL "C" 100A. MLO 120Y/208V, 3Ø, 4W 2 EXISTING 400A-3P TO REMAIN. 1 2 5 EXISTING LANDLORD'S SWTICHGEAR MAIN DISTRIBUTION, FULLY RATED 65KAIC, 480Y/277V-3ɸ-4W, 1200AMP MCB, LANDLORD MAIN ELECTRICAL ROOM NEUT. BUS GND. BUS 3 TRANSFORMER FED FROM EXSIT. 100A/3P CIRCUIT BREAKER IN EXIST. PANEL 'E' 208V-3ɸ-4W SECONDARY 4 T-1 4 4 4 CONTRACTOR IS RESPONSIBLE FOR LOADING ON ALL PANELS AND FEEDERS PER THE N.E.C. CONTRACTOR SHALL KEEP CIRCUIT CONTINUITY TO DEVICES TO REMAIN. E.C. SHALL VERIFY THAT ALL LOADS PLACED ON EXISTING PANELS AND FEEDERS DO NOT EXCEED THE MAXIMUM LOADING REQUIREMENT PER THE LATEST EDITION OF THE NEC. NOTIFY A/E IF OVERLOAD IS POSSIBLE. ONE LINE DIAGRAM SHOWN FOR REFERENCE ONLY TO SHOW GENERAL ARRANGEMENT OF PANELS. E.C. SHALL FIELD VERIFY ALL FEEDERS AND ARRANGEMENT OF PANELS IN FIELD PRIOR TO BID. NOTIFY A/E OF ANY DISCREPANCIES THAT WOULD PROHIBIT COMPLETION OF WORK. EXISTING MAIN SWITCHGEAR POSITION GIVEN FOR GENERAL ARRANGEMENT OF CIRCUITS AND FEEDERS. EXISTING MAIN CIRCUIT BREAKER AND OR FUSES TO BE REUSED TO SERVE NEW/EXISTING PNC PANELBOARDS. E.C. SHALL VERIFY AVAILABLE CIRCUITS AFTER DEMOLITION AND REUSE FOR NEW/EXISTING PNC PANELBOARDS. PROVIDE TYPED UPDATED PANEL DIRECTORIES AFTER NEW WORK IS COMPLETE. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. 06/20/2019 07/23/19 William Hohlt