Loading...
HomeMy WebLinkAboutE-6011 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\050_201919032_E-601.dwg June 19, 2019 - ecurryE-601LIGHTING CONTROL DETAILSMAR LT QSGR-TC-3S-WH-CPN5825 QS TIMECLOCK 4 GANG BACKBOX LOCATE IN I.T./ELEC. RM. 102 ADJACENT TO ESN-A & ESN-B QSE-CI-AP-D ENERGI SAVR NODE PROGRAMMING INTERFACE LOCATE IN I.T./ELEC. RM. 102 APPLE IPOD TOUCH OR IPHONE MOBILE DIGITAL DEVICE ® ® C-ESN-SETUP KIT WIRELESS ROUTER E Q-LINK 1 277/120V: P1-2 QSN-4T16-S ENERGI SAVR NODE QS (ESN)WITH (4) 0-10V CHANNELS AND(1) QS COMMUNICATIONS LINK ZONE 1: 0-10V DIMMING TO SINGLE OFFICES, OPEN AREA OFFICES, TEAM ROOM AND CONFERENCE ROOM, TYPES 'L01' & 'L15'. LUTRON QSM2-4W-C QUANTUM SENSOR MODULE (QSM) WITH WIRED & WIRELESS INPUTS LOCATE IN I.T. / ELEC RM 102 SYMBOL ON PLAN - 120V: C-1 QSN-4S16-S ENERGI SAVR NODE QS (ESN)WITH (4) SWITCHED OUTPUTS, AND(1) QS COMMUNICATIONS LINK ZONE 5: XXXX 120V: D-22 Q-LINK 1 Q-LINK 1 Q-LINK 1 ESN-B LOCATE IN LOCATE IN I.T. / ELEC RM 102 WIRING NOTES: QS LINK WIRING AS REQUIRED BY CONTROL LINK LENGTH (SEE CHART BELOW): CONTROL LINK LENGTH WIRE GAUGE AVAILABLE FROM LUTRON IN ONE CABLE: LESS THAN 500FT (153M) POWER (TERMINALS 1&2): 1 PAIR 18 AWG (1.0MM²) GRX-CBL-346S or GRX-PCBL-346S DATA (TERMINALS 3&4): 1 PAIR 22 AWG (0.5MM²), TWISTED AND SHIELDED* 500ft (153m) to 2000ft (610m)** POWER (TERMINALS 1&2): 1 PAIR 12 AWG (1.0MM²) GRX-CBL-46LDATA (TERMINALS 3&4): 1 PAIR 22 AWG (0.5MM²), TWISTED AND SHIELDED* E 2#12AWG,1#12(G) CAT5E OR BETTER CABLE FOR DEDICATED LUTRON NETWORK TERMINATED WITH RJ45 CONNECTORS (TO BE PROVIDED BY OTHERS). 328 FEET (100M) MAXIMUM RUN. 0-10V SIGNAL OR LV CONTROL: 2#18AWG WIRING LEGEND QS 1. ALL LUTRON LIGHTING CONTROL SYSTEM COMPONENTS ARE PNC FURNISHED THRU VILLA LIGHTING, EXCEPT FOR THE LOW VOLTAGE CABLES, WHICH SHALL BE BY THE E.C. REFER TO THE MATRIX OF RESPONSIBILITY ON TS-001 FOR VENDOR INFORMATION. VILLA LIGHTING CONTACTS: MATT KAESTNER, 314-633-0456, matt.kaestner@villalighting.com OR, DAN PUELLMANN, 314-633-0472, dan.puellmann@villalighting.com. E.C. IS RESPONSIBLE FOR CONTACTING VILLA LIGHTING TO PLACE ORDER. 2. THE QS CONTROL LINK HAS A FREE WIRING TOPOLOGY (DAISY CHAIN, T-TAP, ETC). THE SYSTEM WIRING ILLUSTRATED BY THIS DIAGRAM HAS BEEN LAID OUT TO ENSURE APPROPRIATE POWER TO EACH DEVICE. IF, FOR ANY REASON, THE SYSTEM IS TO BE WIRED DIFFERENTLY THAN WHAT IS SHOWN, CONFIRM ALL DEVICE POWER REQUIREMENTS ARE MET. 3. INSTALLATION OF LIGHTING CONTROL COMPONENTS SHALL COMPLY WITH MANUFACTURERS INSTRUCTIONS AND REQUIREMENTS. GENERAL LIGHTING CONTROL SYSTEM NOTES PJ2-2BRL-GWG-L01 434 MHZ PICO WIRELESS 2 BUTTON CONTROL WITH RAISE/LOWER WITH CW-1-WH CLARO WALLPLATE. SYMBOL ON PLAN - LRF2-OCR2B-P-WH 434MHZ WIRELESS OCCUPANCY/VACANCY SENSOR. DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED. DOES NOT REQUIRE POWER FEED. SYMBOL ON PLAN - RF RF LRF2-DCRB-P-WH 434MHZ WIRELESS DAYLIGHT SENSOR. DEVICE IS SURFACE-MOUNTED AND BATTERY POWERED. DOES NOT REQUIRE POWER FEED. SYMBOL ON PLAN - RF SWITCHED POWER (5A MAX) 0-10V DIM (60 mA MAX) 'POWPAK' DIMMING MODULE WITH 0-10 V CONTROL RMJ-8T-DV-B RF VS DS LPPSYMBOL ON PLAN - PWS(OCCURS IN FLEX 104/105/106 ONLY) NOTES: 1. REFER TO DETAIL 1/E-602 FOR WIRING LEGEND AND LIGHTING CONTROL SYSTEM GENERAL NOTES. 2. TYPICAL FOR THE FOLLOWING ROOMS: COLLABORATIVE 104, FLEX RMS 105,106,107, BREAK RM 109, CASH ROOM 110 AND OFF STAGE 114. PX-2B-GWH-I01 PICO WIRED 2 BUTTON CONTROL WITH CW-1-WH CLARO WALLPLATE, LOCATE IN OPEN AREA. SWITCH SHALL OVERRIDE ALL NETWORKED INTERIOR LIGHTS IN OPEN AREA (ESN-A ZONE 1). SYMBOL ON PLAN - PWCS H N LOAD TS 1:00 D A L O VSS 6 TIMER SWITCH WIRING DIAGRAM N.T.S.4 AND NIGHT LIGHT WIRING DIAGRAM CONTROLLED COMBINATION EMERGENCY N.T.S. 3 SENSOR WIRING DIAGRAM WALL MOUNTED VACANCY N.T.S. 2 LIGHTING CONTROL DIAGRAM LUTRON INDIVIDUAL ROOM N.T.S. 1 LUTRON LIGHTING CONTROL SYSTEM WIRING DIAGRAM N.T.S. NOTE: EXHAUST FAN (ZONE 5) SHALL BE PROGRAMMED FOR TIME OF DAY CONTROL. COORDINATE SCHEDULE WITH PNC. 5 LIGHT WIRING DIAGRAM CONTROLLED EMERGENCY N.T.S. ZONE 6: XXXXZONE 1: SWITCHED POWER TO SINGLE OFFICES, OPEN AREA OFFICES, TEAM ROOM AND CONFERENCE ROOM, TYPES 'L01' & 'L15'. ZONES 2, 3 AND 4 ARE SPARE ZONES ZONE 7 & 8 IS A SPARE ZONE 120V: CIRCUIT # VARIES SEE E-110 120V: C-3 ESN-A LOCATE IN I.T./ELEC. RM. 102 120V: D-24 RF 434 MHZ PICO WIRELESS 2 BUTTON CONTROL WITH CW-1-WH CLARO WALLPLATE. LOCATE SWITCH IN IT/DATA/ELECTRICAL 101. SWITCH SHALL OVERRIDE EXTERIOR SIGN (ESN-B, ZONE 6). SYMBOL ON PLAN - PJ2-2B-GWG-L01 QSS 120V: D-24 06/20/2019 07/23/19 William Hohlt