HomeMy WebLinkAboutE-6021 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\050_201919032_E-602.dwg June 19, 2019 - ecurryE-602ELECTRICAL DETAILSMAR LT IDENTIFY EACH CABLE SEGMENT AT SUBMIT LISTING OF NAMEPLATES FOR APPROVAL. CABLE MARKERS-PANDUIT SELF LAMINATING TYPE PSWM. LAMINATED NAMEPLATE-SIMILIAR TO ABOVE-SEE DETAIL. 3. 2. 1. NOTES: EACH END. BOX #-OUTLET "001-D2" "001-V1" "015-TV" "001-D1" INDICATE THUS. EXAMPLE: VC 70V ALL SPEAKER AND VOLUME CONTROL WIRE IS TO BE WPW #25224WT OR EQUIV. 18G/2C TWISTED PLENUM LOCATION TO BE DETERMINED BY PNC 1. ALL CABLING RUNS SHALL BE ESTIMATED AT 200' FOR BIDDING PURPOSES. CONSTRUCTION DRAWINGS SHALL BE ISSUED WITH FINAL LOCATIONS AT A LATER DATE. 2. CONTRACTOR SHALL FURNISH AND INSTALL AV CABLING ONLY. EQUIPMENT AND TERMINATIONS PROVIDED BY OTHERS UNDER A SEPARATE CONTRACT. 3. ALL ROUGH-INS FOR VOLUME CONTROLS SHALL BE ADJACENT TO LIGHT SWITCHES. 4. TAP SPEAKERS IN LOBBY 101, CHECK DESK 108 AND CONCIERGE 111 AT 4W. EACH AND SPEAKERS IN FLEX OFFICES AT 1W. EACH. (6) ATLAS SD72W SPKRS IN LOBBY 101, CHECK DESK 108 AND CONCIERGE 111 VC ATLAS AT10 FUTURE MUSIC SOURCE (1) ATLAS SD72W SPKR IN FLEX 106. VC VC PASO MUDMA230 AMPLIFIER 9 10 11 12 DVR 2 13 11 11 11 11 11 11 11 13 16 9 1 3 3 414 5 12 12 15 6 7 8 6 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RACK FRONT VIEW TELECOMMUNICATIONS DATA RACK GENERAL NOTES 1. ADD (1) ADDITIONAL HORIZONTAL WIRE MANAGER FOR EACH NETWORK SWITCH. 2. AT BRANCHES WITH MORE THAN 44 DATA DROP LOCATIONS, (2) ADDITIONAL PATCH PANELS WILL BE ADDED AFTER EACH 48 PORT PATCH PANEL. TELECOMMUNICATIONS DATA RACK NUMBERED NOTES BRANCH 24 PORT ANALOG EXTENSION PANEL, HUBBELL 25 PORT PATCH PANEL #P5E22BUE. BRANCH A PATCH PANELS, HUBBELL 48 PORT PATCH PANEL #HP648. BRANCH CISCO 2960 POE SWITCH. 2900 SERIES ROUTER. BRANCH OUT OF BAND ROUTER & BACKUP ROUTER. HUBBELL 10 OUTLET POWER STRIP #HPWPWR. BRANCH DIGITAL MERCHANDISING PC(S) & TIC DUAL WRITE PC(S). BRANCH DVR. HUBBELL 84" FLOOR MOUNT DATA RACK #HPW84RR19. HUBBELL VERTICAL WIRE MANAGER #VS76. INSTALL ON WALL SIDE OF RACK. HUBBELL 2 U HORIZONTAL WIRE MANAGERS #HC219CE3N. HUBBELL CANTILEVERED SHELF #MCCCS19. HUBBELL REAR CABLE ORGANIZER BAR #ECMBR3 (1 PER HORIZONTAL CABLING PATCH PANEL, REAR OF RACK) 25 PAIR VOICE CABLE WITH AMPHENAL MALE CONNECTOR. 66 BLOCK IS AT THE DEMARC AND CONNECTS TO #1 ON THE RACK VIA A 25 PAIR CAT5E CABLE. BRANCH B PATCH PANELS, HUBBELL 48 PORT PATCH PANEL #HP648. 9 10 11 12 1 134 2 3 3 5 (1) CAT5E 6 7 8 6 1 2 3 4 5 6 7 8 9 10 11 12 13 INCOMING TELEPHONE CABLE. 66 BLOCKS PROVIDED FOR INCOMING TELEPHONE COMPANY CABLE. NUMBER OF PAIRS AS SPECIFIED BY THE TELEPHONE SERVICE PROVIDER. PROVIDE CROSS CONNECT CABLES SO THAT EVERY PAIR IS CONNECTED TO EACH TERMINATION BLOCK. 66 BLOCK ON PROTECTED SIDE OF CABLE PROTECTORS. SEE EQUIPMENT ELEVATIONS ON DETAIL 9/E-5 FOR MORE INFORMATION. PNC SHALL EXTEND ALL ANALOG LINES FROM PATCH PANEL TO 66 BLOCKS. PROVIDE 48 PORT CAT 5E PATCH PANEL MOUNTED IN RACK. TERMINATE THE CAT 5E CABLES. DATA EQUIPMENT RACK WITH OWNER PROVIDED ELECTRONICS. OWNER PROVIDED VOIP SWITCH. PROVIDE (1) CAT 5E CABLE FROM EVERY JACK TO PATCH PANEL IN EQUIPMENT RACK. TERMINATE EVERY CABLE AT BOTH ENDS. PROVIDE CAT 5E PATCH CABLES AT EACH END OF NEW CABLE RUNS. AT OUTLET PROVIDE 10' CABLE AND AT PATCH PANEL PROVIDE 5' CABLES. ALL PATCH CABLES SHALL BE INSTALLED INTO THE PATCH PANEL. CABLE GUIDES ARE TO BE USED TO KEEP THE CABLES ORDERLY. THE EQUIPMENT END OF THE PATCH CABLE IS TO BE LEFT HANGING IN FRONT OF THE RACK. THESE WILL BE PATCHED INTO THE OWNER PROVIDED ELECTRONICS BY THE PNC BANK IT DEPARTMENT. IF THE CONTRACTOR PROVIDES ANY OPENINGS THROUGH WALLS, FLOOR, ETC. THEN THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIRESTOP SEALING, PATCHING, AND PAINTING ALL AREAS DISTURBED BY THIS CONTRACT. CABLE PROTECTORS. EVER INCOMING COPPER CABLE MUST BE PROTECTED. PROTECTORS ARE SPECIFIED IN THE SPECIFICATIONS. TELECOMMUNICATIONS WIRING DIAGRAM NUMBERED NOTES VC ATLAS AT10 ATLAS AT10 ATLAS AT10 ATLAS AT10 (1) ATLAS SD72W SPKR IN FLEX 105. (1) ATLAS SD72W SPKR IN COLLABORATIVE 104. (1) ATLAS SD72W SPKR IN FLEX 107. TOP VIEW WALL ANCHOR WALL METAL BRACKET STAND OFF INSULATOR COPPER BUS .281" DIA HOLE 4" 1" 16" 1/4" X 4" COPPER BUS 6 AUDIO BACKBONE SINGLE LINE DIAGRAM N.T.S. 4 TELECOMMUNICATIONS WIRING DIAGRAM N.T.S. 3 TELECOMMUNICATIONS DATA RACK ELEVATION N.T.S. 2 CABLE MARKER DETAIL N.T.S. 1 COPPER GROUND BAR DETAIL N.T.S.7 CARD READER/SECURITY INTERFACE N.T.S. J2-6J2-4 PARABIT CARD READER CONTROLLER LOCATED IN TELE/DATA 102 (1) 8 CONDUCTOR #18AWG STRANDED CABLE, BELDEN #6360UE (1) 4 CONDUCTOR #22AWG STRANDED CABLE, BELDEN #6502UE CARD READER FURNISHED WITH PARABIT CONTROLLER AT EXTERIOR SWINGING LOBBY DOOR. DOOR LOCKING DEVICE FURNISHED WITH DOOR HARDWARE PACKAGE AND INSTALLED BY G.C. DOOR LOCKING DEVICE POWER SUPPLY FURNISHED WITH DOOR HARDWARE PACKAGE, AND INSTALLED AND WIRED BY E.C.(1) 4 CONDUCTOR #18AWG STRANDED CABLE, BELDEN #6302UE DIEBOLD "DMP" PANEL LOCATED IN TELE/DATA 102 (1) 8 CONDUCTOR #22AWG STRANDED CABLE, BELDEN #6560UE NUMBERED NOTES DIEBOLD FURNISHES AND INSTALLS DEVICE AND MAKES WIRE TERMINATIONS. E.C. FURNISHES AND INSTALLS 120VAC POWER. REFER TO E-101. LVC FURNISHES AND INSTALLS LOW VOLTAGE CABLE. 06/20/2019 07/23/19 William Hohlt