HomeMy WebLinkAboutI-201T.9'-0"HOLD7
RB1
P1
T.
8
T.
9
T.
10
T.
11
T.
12
3
I-202
RB1
P1
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9'-0"
T. = TEMPERED (SAFETY GLAZING)
T.T. T.T. T.T. T.T. T.T. T.T.
PNC OFFICE VINYL GRAPHIC
INSTALLED ON GLAZING, TYP.
OFFICE FRONT INTERIOR SAFETY GLAZING
SYSTEM AND DOORS SUPPLIED AND
INSTALLED BY OTHERS
T.
6
P1
5
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9-0"
T. = TEMPERED (SAFETY GLAZING)
T.T. 9'-0"HOLD3
I-202
RB1
PNC OFFICE VINYL GRAPHIC
INSTALLED ON GLAZING, TYP.
OFFICE FRONT INTERIOR SAFETY GLAZING
SYSTEM AND DOORS SUPPLIED AND
INSTALLED BY OTHERS
T.
13
3
I-202
T.T. T.
14
T.T. T.
15
T.T.
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9-0"9'-0"HOLDOFFICE FRONT INTERIOR SAFETY GLAZING
SYSTEM AND DOORS SUPPLIED AND
INSTALLED BY OTHERS
PNC OFFICE VINYL
GRAPHIC INSTALLED
ON GLAZING, TYP.
13'-9"5'-0"℄
MOUNT
℄
NEW 55" LCD TV. PROVIDE APPROPRIATE
FIRE RETARDANT TREATED PLYWD AND
BLOCKING (MIN 6" X 18" X 3/4") BETWEEN
STUDS FROM HORIZONTAL CENTERLINE
AND UP; PROVIDE J-BOXES FOR POWER
AND CABLE CONNECTIONS. REFER TO
ELECTRICAL
IN-WALL BOX AND TV MOUNT PROVIDED
BY PNC AND INSTALLED BY G.C. HEIGHT
OF TV MOUNT TO BE COORDINATED WITH
PNC PRIOR TO INSTALLATION OF
POWER/DATA. G.C. TO VERIFY
INFRASTRUCTURE LOCATIONS WITH AV
SHOP DRAWINGS
RB1
4
I-202
3
7'-9"6'-0"
P1
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9-0"18"TYP.MIRROR
PL1 BASE CABINETS
2'-10"HORIZONTAL POWER OUTLET.
REFER TO ELECTRICAL
DRAWINGS. TYP.
3'-0"
(2 EQUAL)
P1
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9'-0"
U/C REFRIGERATOR
(SHOWN DASHED)
1'-10" 1'-7"
6
I-501
3
I-501
4
I-501
5
I-501
SS1 COUNTERTOP
AND BACKSPLASH
WALL-MOUNTED
MAKE-UP MIRROR
4'-6"SS1 COUNTERTOP
AND BACKSPLASH
HORIZONTAL POWER/DATA
OUTLETS. REFER TO
ELECTRICAL DRAWINGS. TYP.
P1
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9'-0"2'-10" 12" MEGAWALL SLAT SYSTEM W/
2 SLATWALL BINS #MODEL TBD,
1" CLEAR ANOD. ALUM.
UPPER CABINET
8'-9"
(6 EQUAL)
1
I-501
8'-9"
(6 EQUAL)
2
I-501
7
I-501
2'-0" 2'-0"1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
2019190.32
PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19
06/19/19
-
-REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\020_201919032_I-20X.dwg
June 19, 2019 - ecurryI-201INTERIOR ELEVATIONSMAR EBC2
1 INTERIOR ELEVATION -OPEN AREA (OFFICES)
1/2" = 1/-0"
2 INTERIOR ELEVATION -OPEN AREA (TEAM ROOM 117)
1/2" = 1/-0"3 INTERIOR ELEVATION -OPEN AREA (OFFICES)
1/2" = 1/-0"
4 INTERIOR ELEVATION - CONFERENCE ROOM
1/2" = 1/-0"5 INTERIOR ELEVATION - NEW MOTHER'S ROOM
1/2" = 1/-0"6 INTERIOR ELEVATION - SERVICE CENTER
1/2" = 1/-0"
06/20/2019
07/23/19
William Hohlt
P1
FIN. FLR.
EL. = 0'-0"
CLG. HT.
EL. = 9'-0"5'-0"℄
3
℄
MOUNT
4
I-202
10'-7"
RB1
NEW 65" LCD TV. PROVIDE APPROPRIATE FIRE
RETARDANT TREATED PLYWD AND BLOCKING
(MIN 6" X 18" X 3/4") BETWEEN STUDS FROM
HORIZONTAL CENTERLINE AND UP; PROVIDE
J-BOXES FOR POWER AND CABLE
CONNECTIONS. REFER TO ELECTRICAL
IN-WALL BOX AND TV MOUNT PROVIDED BY PNC
AND INSTALLED BY G.C. HEIGHT OF TV MOUNT TO
BE COORDINATED WITH PNC PRIOR TO
INSTALLATION OF POWER/DATA. G.C. TO VERIFY
INFRASTRUCTURE LOCATIONS WITH AV SHOP
DRAWINGS.
CLG. HT.
ELEV. = 9'-0"
3 1/2" SOUND ATTENUATION
BLANKET INSULATION.
5/8" GYPSUM BOARD,
BOTH SIDES.
WALL BASE. REFER TO
FINISH SCHEDULE.
BRACE STUDS TO
STRUCTURE ABOVE @ 48"
O.C. MAX.
5"
3- 5/8" METAL
STUDS @ 16" O.C.6"SUSP. CEILING PER
REFLECTED CEILING PLAN
FIN. FLR.
ELEV. = 0'-0"
FIN. FLR.
ELEV. = 0'-0"
CLG. HT.
ELEV. = 9'-0"6"SUSP. CEILING PER
REFLECTED CEILING PLAN
OFFICE FRONT INTERIOR SAFETY
GLAZING SYSTEM AND DOORS SUPPLIED
AND INSTALLED BY OTHERS.
BRACE STUDS TO STRUCTURE
ABOVE @ 48" O.C. MAX.
5/8" GYPSUM BOARD ON
3 5/8" METAL STUDS @ 16" O.C.,
PAINT UNDERSIDE OF
BULKHEAD P1
LIGHT GAUGE 6" MTL
STUD BOX HEADER
ELECTRICIAN TO PROVIDE REQUIRED
NUMBER OF RECESSED OUTLETS AND
DATA JUNCTION BOXES. COORDINATE
LOCATION WITH MONITOR. REFER TO
ELECTRICAL DRAWINGS FOR DETAILS
5/8" GYP. BD. ON 3 5/8" MTL.
STUDS @ 16 O.C. P1
MONITOR ON TV MOUNT,
(CHIEF #TS318TU) ON IN-WALL
BOX (CHIEF #TA501) PROVIDED
BY PNC. INSTALLED BY G.C.
WD. BLOCKING AS REQ'D., TYP.
℄5'-0"TO FINISH FLOOREXST'G. STOREFRONT
GLAZING
3/8" CLEAR SILICONE
SEALANT JOINT
22 GA BREAK METAL TO
MATCH EXST'G.
STOREFRONT
PARTITION AS
SCHEDULED
1/2" OVERLAPCOMPRESSION JOINT
FILLER
3 5/8" X 20 GA BRACE @ 4'-0"
O.C. (ALTERNATE DIRECTION)
LS543 SWIFTCLIP
SIMPSON SJC10.25 INSTALL TO UNDERSIDE
OF STRUCTURE USING (2) 3/8" DIA TITEN HD
ANCHORS (2 1/2" MIN. EMBED)
EXIST. JOIST OR GIRDER
NOTE: DETAIL APPLIES AT
PARTIAL-HEIGHT WALLS.
FTC3 INSTALL TO UNDERSIDE
OF STRUCTURE USING (2) 1/4"
DIA., 1 3/4" LONG HILTI KWIK
CON ANCHORS
CONT. 3" DEEP LEG TRACK
EXIST. JOIST OR GIRDER
NOTE: DETAIL APPLIES AT
FULL-HEIGHT WALLS.
EXST'G. STOREFRONT
GLAZING
OFFICE FRONT INTERIOR SAFETY
GLAZING SYSTEM AND DOORS
SUPPLIED AND INSTALLED BY
OTHERS
2 7/8" MIN.3 15/16" MAX.2" GASKET WITH
ADHESIVE
ADJUSTABLE PARTITION
CLOSURE TO MATCH
EXST. STOREFRONT
COMPRESSION JOINT
FILLER
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
2019190.32
PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19
06/19/19
-
-REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\020_201919032_I-20X.dwg
June 19, 2019 - ecurryI-202INTERIOR ELEVATIONS,INTERIOR WALL SECTIONSAND DETAILSMAR EBC2
1 INTERIOR ELEVATION - TRAINING
1/2" = 1/-0"2 INTERIOR WALL SECTION
3/4" = 1/-0" 3 INTERIOR WALL SECTION
3/4" = 1/-0"
4 SECTION AT WALL-MOUNTED TV
1 1/2" = 1'-0"5 PLAN DETAIL
3" = 1'-0"
8 TOP OF WALL BRACE
3/4"=1'-0"
7 TOP OF WALL BRACE
3/4"=1'-0"
6 PLAN DETAIL
3" = 1'-0"
06/20/2019
07/23/19
William Hohlt