Loading...
HomeMy WebLinkAboutI-201T.9'-0"HOLD7 RB1 P1 T. 8 T. 9 T. 10 T. 11 T. 12 3 I-202 RB1 P1 FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9'-0" T. = TEMPERED (SAFETY GLAZING) T.T. T.T. T.T. T.T. T.T. T.T. PNC OFFICE VINYL GRAPHIC INSTALLED ON GLAZING, TYP. OFFICE FRONT INTERIOR SAFETY GLAZING SYSTEM AND DOORS SUPPLIED AND INSTALLED BY OTHERS T. 6 P1 5 FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9-0" T. = TEMPERED (SAFETY GLAZING) T.T. 9'-0"HOLD3 I-202 RB1 PNC OFFICE VINYL GRAPHIC INSTALLED ON GLAZING, TYP. OFFICE FRONT INTERIOR SAFETY GLAZING SYSTEM AND DOORS SUPPLIED AND INSTALLED BY OTHERS T. 13 3 I-202 T.T. T. 14 T.T. T. 15 T.T. FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9-0"9'-0"HOLDOFFICE FRONT INTERIOR SAFETY GLAZING SYSTEM AND DOORS SUPPLIED AND INSTALLED BY OTHERS PNC OFFICE VINYL GRAPHIC INSTALLED ON GLAZING, TYP. 13'-9"5'-0"℄ MOUNT ℄ NEW 55" LCD TV. PROVIDE APPROPRIATE FIRE RETARDANT TREATED PLYWD AND BLOCKING (MIN 6" X 18" X 3/4") BETWEEN STUDS FROM HORIZONTAL CENTERLINE AND UP; PROVIDE J-BOXES FOR POWER AND CABLE CONNECTIONS. REFER TO ELECTRICAL IN-WALL BOX AND TV MOUNT PROVIDED BY PNC AND INSTALLED BY G.C. HEIGHT OF TV MOUNT TO BE COORDINATED WITH PNC PRIOR TO INSTALLATION OF POWER/DATA. G.C. TO VERIFY INFRASTRUCTURE LOCATIONS WITH AV SHOP DRAWINGS RB1 4 I-202 3 7'-9"6'-0" P1 FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9-0"18"TYP.MIRROR PL1 BASE CABINETS 2'-10"HORIZONTAL POWER OUTLET. REFER TO ELECTRICAL DRAWINGS. TYP. 3'-0" (2 EQUAL) P1 FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9'-0" U/C REFRIGERATOR (SHOWN DASHED) 1'-10" 1'-7" 6 I-501 3 I-501 4 I-501 5 I-501 SS1 COUNTERTOP AND BACKSPLASH WALL-MOUNTED MAKE-UP MIRROR 4'-6"SS1 COUNTERTOP AND BACKSPLASH HORIZONTAL POWER/DATA OUTLETS. REFER TO ELECTRICAL DRAWINGS. TYP. P1 FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9'-0"2'-10" 12" MEGAWALL SLAT SYSTEM W/ 2 SLATWALL BINS #MODEL TBD, 1" CLEAR ANOD. ALUM. UPPER CABINET 8'-9" (6 EQUAL) 1 I-501 8'-9" (6 EQUAL) 2 I-501 7 I-501 2'-0" 2'-0"1 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\020_201919032_I-20X.dwg June 19, 2019 - ecurryI-201INTERIOR ELEVATIONSMAR EBC2 1 INTERIOR ELEVATION -OPEN AREA (OFFICES) 1/2" = 1/-0" 2 INTERIOR ELEVATION -OPEN AREA (TEAM ROOM 117) 1/2" = 1/-0"3 INTERIOR ELEVATION -OPEN AREA (OFFICES) 1/2" = 1/-0" 4 INTERIOR ELEVATION - CONFERENCE ROOM 1/2" = 1/-0"5 INTERIOR ELEVATION - NEW MOTHER'S ROOM 1/2" = 1/-0"6 INTERIOR ELEVATION - SERVICE CENTER 1/2" = 1/-0" 06/20/2019 07/23/19 William Hohlt P1 FIN. FLR. EL. = 0'-0" CLG. HT. EL. = 9'-0"5'-0"℄ 3 ℄ MOUNT 4 I-202 10'-7" RB1 NEW 65" LCD TV. PROVIDE APPROPRIATE FIRE RETARDANT TREATED PLYWD AND BLOCKING (MIN 6" X 18" X 3/4") BETWEEN STUDS FROM HORIZONTAL CENTERLINE AND UP; PROVIDE J-BOXES FOR POWER AND CABLE CONNECTIONS. REFER TO ELECTRICAL IN-WALL BOX AND TV MOUNT PROVIDED BY PNC AND INSTALLED BY G.C. HEIGHT OF TV MOUNT TO BE COORDINATED WITH PNC PRIOR TO INSTALLATION OF POWER/DATA. G.C. TO VERIFY INFRASTRUCTURE LOCATIONS WITH AV SHOP DRAWINGS. CLG. HT. ELEV. = 9'-0" 3 1/2" SOUND ATTENUATION BLANKET INSULATION. 5/8" GYPSUM BOARD, BOTH SIDES. WALL BASE. REFER TO FINISH SCHEDULE. BRACE STUDS TO STRUCTURE ABOVE @ 48" O.C. MAX. 5" 3- 5/8" METAL STUDS @ 16" O.C.6"SUSP. CEILING PER REFLECTED CEILING PLAN FIN. FLR. ELEV. = 0'-0" FIN. FLR. ELEV. = 0'-0" CLG. HT. ELEV. = 9'-0"6"SUSP. CEILING PER REFLECTED CEILING PLAN OFFICE FRONT INTERIOR SAFETY GLAZING SYSTEM AND DOORS SUPPLIED AND INSTALLED BY OTHERS. BRACE STUDS TO STRUCTURE ABOVE @ 48" O.C. MAX. 5/8" GYPSUM BOARD ON 3 5/8" METAL STUDS @ 16" O.C., PAINT UNDERSIDE OF BULKHEAD P1 LIGHT GAUGE 6" MTL STUD BOX HEADER ELECTRICIAN TO PROVIDE REQUIRED NUMBER OF RECESSED OUTLETS AND DATA JUNCTION BOXES. COORDINATE LOCATION WITH MONITOR. REFER TO ELECTRICAL DRAWINGS FOR DETAILS 5/8" GYP. BD. ON 3 5/8" MTL. STUDS @ 16 O.C. P1 MONITOR ON TV MOUNT, (CHIEF #TS318TU) ON IN-WALL BOX (CHIEF #TA501) PROVIDED BY PNC. INSTALLED BY G.C. WD. BLOCKING AS REQ'D., TYP. ℄5'-0"TO FINISH FLOOREXST'G. STOREFRONT GLAZING 3/8" CLEAR SILICONE SEALANT JOINT 22 GA BREAK METAL TO MATCH EXST'G. STOREFRONT PARTITION AS SCHEDULED 1/2" OVERLAPCOMPRESSION JOINT FILLER 3 5/8" X 20 GA BRACE @ 4'-0" O.C. (ALTERNATE DIRECTION) LS543 SWIFTCLIP SIMPSON SJC10.25 INSTALL TO UNDERSIDE OF STRUCTURE USING (2) 3/8" DIA TITEN HD ANCHORS (2 1/2" MIN. EMBED) EXIST. JOIST OR GIRDER NOTE: DETAIL APPLIES AT PARTIAL-HEIGHT WALLS. FTC3 INSTALL TO UNDERSIDE OF STRUCTURE USING (2) 1/4" DIA., 1 3/4" LONG HILTI KWIK CON ANCHORS CONT. 3" DEEP LEG TRACK EXIST. JOIST OR GIRDER NOTE: DETAIL APPLIES AT FULL-HEIGHT WALLS. EXST'G. STOREFRONT GLAZING OFFICE FRONT INTERIOR SAFETY GLAZING SYSTEM AND DOORS SUPPLIED AND INSTALLED BY OTHERS 2 7/8" MIN.3 15/16" MAX.2" GASKET WITH ADHESIVE ADJUSTABLE PARTITION CLOSURE TO MATCH EXST. STOREFRONT COMPRESSION JOINT FILLER 1 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\020_201919032_I-20X.dwg June 19, 2019 - ecurryI-202INTERIOR ELEVATIONS,INTERIOR WALL SECTIONSAND DETAILSMAR EBC2 1 INTERIOR ELEVATION - TRAINING 1/2" = 1/-0"2 INTERIOR WALL SECTION 3/4" = 1/-0" 3 INTERIOR WALL SECTION 3/4" = 1/-0" 4 SECTION AT WALL-MOUNTED TV 1 1/2" = 1'-0"5 PLAN DETAIL 3" = 1'-0" 8 TOP OF WALL BRACE 3/4"=1'-0" 7 TOP OF WALL BRACE 3/4"=1'-0" 6 PLAN DETAIL 3" = 1'-0" 06/20/2019 07/23/19 William Hohlt