HomeMy WebLinkAboutA-101.11 FLOOR PLAN
1/4"=1'-0"
1 2 3 4 5
B
A
JOB NO.
D
C
ISSUED FOR:
PERMIT
RECORD
CONSTRUCTION
BID
520 South Main Street, Suite 2531
Akron, OH 44311
330.572.2100 Fax 330.572.2102
2019190.32
PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19
06/19/19
-
-
N REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\010_201919032_A-101.dwg
June 19, 2019 - ecurryA-101.1FLOOR PLANMAR EBC2MATCH LINE - SEE 1/A-101OFFICE
113
OFFICE
114
OFFICE
115
TRAINING
119
FUTURE TENANT
UNOCCUPIED
---
LOBBY 2
103
VESTIBULE 2
ENTRY
102
8 9 8
13
14
15
16
18
17
19
20
3I-201
2 8
2 8
2 8
5
1
I-201
17
17
17
STORAGE
121
8
FUTURE TENANT
UNOCCUPIED
---
8
A. DO NOT SCALE DRAWINGS.
B. THE BUILDING IS TO BE CONSTRUCTED IN COMPLIANCE WITH ASHRAE 90.1 OR PER THE LOCAL ENERGY
CODE REQUIREMENTS.
C. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CROSS-CHECK THE MEP DRAWINGS WITH
THE ARCHITECTURAL DRAWINGS PRIOR TO THE ORDERING / INSTALLATION OF MECHANICAL, ELECTRICAL,
AND PLUMBING WORK. ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND MEP DRAWINGS SHALL
BE BROUGHT TO THE ARCHITECTS ATTENTION FOR IMMEDIATE CLARIFICATION.
D. COORDINATE WORK WITH OTHER TRADES, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE
TENANT AND LANDLORD/BUILDING OWNER, AND THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE
PROJECT SITE. COORDINATE THE INSTALLATION WITH OTHER TRADES AS REQUIRED TO ENSURE A NEAT
AND ORDERLY INSTALLATION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES BEFORE STARTING
WORK.
E. GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION
DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE
DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE
DOCUMENT SET.
F. WHERE THERE MAY BE A CONFLICT IN THE SPECIFICATIONS AND/OR DRAWINGS, THEN THE MORE
EXPENSIVE LABOR, MATERIALS AND EQUIPMENT SHALL BE ASSUMED TO BE REQUIRED AND SHALL BE
PROVIDED BY THE GENERAL CONTRACTOR TO THE SATISFACTION OF THE TENANT.
G. WHEN WORK, NOT SPECIFICALLY CALLED OUT, IS REQUIRED TO COMPLETE THE PROJECT, IT SHALL BE
PROVIDED BY THE GENERAL CONTRACTOR WITH THE BEST MATERIALS AND WORKMANSHIP.
H. G.C. TO REPLACE ALL CARPET WHERE DEMOLITION OCCURS TO MATCH EXISTING TO REMAIN
PLAN KEYNOTES GENERAL NOTES
1. MFD PRINTER TO BE PROVIDED BY PNC.
2. OFFICE FURNITURE BY OTHERS. G.C. TO COORDINATE PLACEMENT WITH PNC.
3. (3) 36" WIDE FLAT FILES WITH COMMON TOP. G.C. TO COORDINATE PLACEMENT WITH PNC.
4. WORKSTATION FURNITURE BY OTHERS. G.C. TO COORDINATE PLACEMENT WITH PNC.
5. 65" MONITOR. REFER TO INTERIOR ELEVATION FOR MOUNTING HEIGHT.
6. BASE CABINETRY. COORDINATE WITH PNC AND VENDOR. SEE 200 SHEETS.
7. COUNTERTOP WITH SUPPORT BRACKETS. BRACKETS TO BE PAINTED TO MATCH ADJACENT
WALL, SEE SHEETS I-501.
8. G. C. TO ENSURE THAT EXISTING AREA IS SMOOTH, LEVEL, AND PREPARED TO RECEIVE NEW
FLOOR FINISH.
9. FURNITURE. PROVIDED BY PNC AND VENDOR.
10. ROD AND SHELF INSTALLED BY G.C.
11. UNDER-COUNTER REFRIGERATOR. G.C. TO COORDINATE PLACEMENT WITH PNC.
12. DROP-IN SINK. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
13. 55" MONITOR. REFER TO INTERIOR ELEVATION FOR MOUNTING HEIGHT.
14. TACK BOARD. COORDINATE PLACEMENT WITH PNC.
15. WASTE STREAM CENTER. COORDINATE PLACEMENT WITH PNC.
16. WALL CABINETRY. COORDINATE WITH PNC AND VENDOR. SEE 200 SHEETS
17. OFFICE FRONT INTERIOR SAFETY GLAZING SYSTEM AND DOORS SUPPLIED AND INSTALLED BY
OTHERS.
LEGEND
ADJACENT TENANT, NO WORK IN THIS
AREA.
-
EXISTING WALL PARTITION
NEW FULL HEIGHT WALL PARTITION
06/20/2019
07/23/19
William Hohlt