Loading...
HomeMy WebLinkAboutA-110.14'-0" 2'-0"2'-11 1/2"2'-5"1 2 3 4 5 B A JOB NO. D C ISSUED FOR: PERMIT RECORD CONSTRUCTION BID 520 South Main Street, Suite 2531 Akron, OH 44311 330.572.2100 Fax 330.572.2102 2019190.32 PNC BANK - PENNWOOD OFFICE11405 NORTH PENNSYVANIA STREETCARMEL, IN 4603206/19/19 06/19/19 - -MATCH LINE - SEE 1/A-110OFFICE 113 OFFICE 114 OFFICE 115 TRAINING 118 FUTURE TENANT UNOCCUPIED --- LOBBY 2 103 2 2 2 2 1 REFLECTED CEILING PLAN 1/4"=1'-0" A. DO NOT SCALE DRAWINGS. B. THE BUILDING IS TO BE CONSTRUCTED IN COMPLIANCE WITH ASHRAE 90.1 OR PER THE LOCAL ENERGY CODE REQUIREMENTS. C. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CROSS-CHECK THE MEP DRAWINGS WITH THE ARCHITECTURAL DRAWINGS PRIOR TO THE ORDERING / INSTALLATION OF MECHANICAL, ELECTRICAL, AND PLUMBING WORK. ANY DISCREPANCIES BETWEEN THE ARCHITECTURAL AND MEP DRAWINGS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION FOR IMMEDIATE CLARIFICATION. D. COORDINATE WORK WITH OTHER TRADES, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE TENANT AND LANDLORD/BUILDING OWNER, AND THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. COORDINATE THE INSTALLATION WITH OTHER TRADES AS REQUIRED TO ENSURE A NEAT AND ORDERLY INSTALLATION. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES BEFORE STARTING WORK. E. GENERAL CONTRACTOR AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. F. WHERE THERE MAY BE A CONFLICT IN THE SPECIFICATIONS AND/OR DRAWINGS, THEN THE MORE EXPENSIVE LABOR, MATERIALS AND EQUIPMENT SHALL BE ASSUMED TO BE REQUIRED AND SHALL BE PROVIDED BY THE GENERAL CONTRACTOR TO THE SATISFACTION OF THE TENANT. G. WHEN WORK, NOT SPECIFICALLY CALLED OUT, IS REQUIRED TO COMPLETE THE PROJECT, IT SHALL BE PROVIDED BY THE GENERAL CONTRACTOR WITH THE BEST MATERIALS AND WORKMANSHIP. H. CEILING GRID HANGER WIRES SHALL NOT BE ATTACHED TO ROOF DECK. HANGERS TO ATTACH TO STRUCTURAL MEMBERS ONLY. MAY REQUIRE ADDITIONAL SUPPORT MEMBERS BE ADDED TO PROVIDE ADDITIONAL LIGHTING SUPPORT AND/OR CEILING SUPPORT, WHEN REQUIRED, PER SEISMIC ZONE AND LOCAL CODE. ATTACHING CEILING DIRECTLY TO DECK IS NOT PERMITTED. I. ELECTRICAL CONTRACTOR SHALL VERIFY PROPER OPERATION OF ALL EMERGENCY LIGHTS, EGRESS LIGHTS, EXIT SIGNS AND ALARM APPLIANCES. REPAIR AND/OR REPLACE AS REQUIRED. EQUIPMENT WILL BE TESTED AT FINAL INSPECTION 1. CENTER CEILING GRID IN SPACE UNLESS NOTED OTHERWISE. 2. WINDOW SHADE, SEE SHEET A-110. 3. START CEILING GRID AT NOTED LOCATION. 4. CENTER LIGHT WITHIN GRID. PLAN KEYNOTES GENERAL NOTES LEGEND ADJACENT TENANT, NO WORK IN THIS AREA. SEE LIGHT FIXTURE SCHEDULE ON ELECTRICAL DRAWINGS FOR MOUNTING HEIGHTS. FIXTURE SYMBOL TYPE NEW 2X2 ACOUSTICAL PANEL CEILING (CL2) NEW LIGHTING FIXTURES. SEE ELECTRICAL. NEW MECHANICAL EQUIPMENT . SEE MECHANICAL N # VESTIBULE 2 ENTRY 102 P1 B.O. BULKHEAD 8'-10" A.F.F. CLG. HGT. 9'-0" A.F.F. 1 2 A-110 STORAGE 121 CLG. HGT. 9'-0" A.F.F. 4 3 CLG. HGT. 9'-0" A.F.F. 1 CLG. HGT. 9'-0" A.F.F. 1 CLG. HGT. 9'-0" A.F.F. 1 CLG. HGT. 9'-0" A.F.F. 1 FUTURE TENANT UNOCCUPIED --- FIXTURE SYMBOL TYPE EXISTING MECHANICAL EQUIPMENT . SEE MECHANICAL 3 REV. DATE DESCRIPTIONDESIGNERPROJECT MANAGER Drawing Name: O:\2019\2019190\32 Carmel (Penn) Office IN\dwg\ConstructionDocuments\Architectural\010_201919032_A-110.dwg June 20, 2019 - ecurryA-110.1REFLECTED CEILING PLANMAR EBC2 06/20/2019 07/23/19 William Hohlt