HomeMy WebLinkAboutA121 Reflected Ceiling PlanLEGEND
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE, 2'A, LED
❑ LIGHT FIXTURE, 2'x2', LED
LIGHT FIXTURE, I'x4', LED,
® INDIRECT
CAN LIGHT FIXTURE
SUSPENDED FROM
DECK; CONFIRM EXACT
SPEC, LOCAITON AND
INSTALL HEIGHT WITH
LANDLORD
®
LIGHT FIXTURE,
PENDANT
NIL
NIGHT LIGHT
®
EXIT LIGHT FIXTURE
®
EXIT LIGHT FIXTURE
JA ®
EMERGENCY LIGHT
EMERGENCY LIGHT FIXTURE
FIXTURE
$N
LIGHTSWRCH
a
LIGHTSWRCH
$N3
LIGHT SWITCH, &WAY
$3
LIGHT SWITCH, &WAY
LIGHT SWITCH, DIMMER
$D
LIGHT SWITCH, DIMMER
AND
$NP
SWITCH, PROJECTOR SCREEN
$p
SWITCH, PROJECTOR SCREEN
$NG
SWITCH, GARBAGE DISPOSAL
$G
SWITCH, GARBAGE DISPOSAL
(ABOVE COUNTERTOP)
$NE
SWITCH, EXHAUST FAN
$G
SWITCH, EXHAUST FAN
i —
UGHTCIRCUIT
......
LIGHTCIRCUIT
CEILING GRID,
SUSPENDED, 7x2'
GYPSUM BOARD
CEILING
■ EXPOSED TO DECK
MRELOCATED
DIFFUSER, LAY IN. 2 X7
RELOCATED
DIFFUSER, LAY -IN, l'x4'
RELOCATED
® DIFFUSER, LAY IN. WNW
® EXHAUST FAN, 2'x2'
CEILING GRID,
_r_ SUSPENDED, Zx2'
® EXISTING DIFFUSER, LAYJN, 2x2'
® EXISTING DIFFUSER, LAYJN, l'x4'
m EXISTING DIFFUSER, LAYJN,
4"X4'
XEXISTING EXHAUSTFAN, 7x2'
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
RELOCATE DIFFUSERS L
, .MECHANICAL DIFFUSER RELOCATION
RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/07/19
AREA NOT IN CONTRACT
❑ AREA OF WORK
GENERAL NOTES
PROVIDE NEW BUILDING STANDARD 2X2CEILING GRID AND TILE
INSTALLED AS HIGH AS POSSIBLE FOR UNIFORM HEIGHT ON ENTIRE
4TH FLOOR. CONFIRM EXACT SPECIFICATIONS WITH LANDLORD.
2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMAANDIBC. LIGHTS CONNECTEDTOAN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR
MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN
RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE
AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE
APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO
DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT
THEIR EXPENSE.
3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS,
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI. OVER 507,OF THE LIGHTING WILL
BE REPLACED WITH NEW, SOASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
4. UNLESS OTHERWISE NOTED, ALL NEW SWITCHES MUST BE AN
OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND
INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE.
OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT
OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN
OPEN AREAS AS REQUIRED.
5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE,
GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH
PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN.
6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND 15
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES,
2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING COMPLETED.
FILTERS MUST BE CHANGED AT CLOSE OF PROJECT AND ALL
THERMOSTATS MUST BE CALIBRATED AND AIR BALANCED, PROVIDE
REPORT TO OWNER.
PLAN NOTES
itJl CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT
AS NOTED ON PLAN PER MANUFACTURER'S RECOMMENDATIONS.
PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK,
SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL
BEAMS AND FIREPROOFING I N ACCORDANCE WITH NFPA 13 6.3.8.
PROVIDE RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY
DIFFUSERS AS REQUIRED IN THIS AREA.
R02 TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 5'
WIDE DRYWALL BULKHEAD EXTENDING FROM 2' BELOW HEIGHT OF
CEILING GRID TO DECK. TRANSITION TO BE A CLEAN VERTICAL
BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS
CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE.
VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF
ADJACENT WALL,
R03 DESIGN INTENT 15 FOR CEILING GRID AND TILE TO STOP IN THIS
LOCATION. SECURE GRID AS REQUIRED FOR FUTURE EXPANSION
OF CEILING IN NORTH END OF SPACE,
OCONFIRM WITH LANDLORD ON EXACT LOCATION AND INSTALL
R04 HEIGHT OF LINEAR FIXTURES IN THIS AREA.
6CONFIRM EXACT PENDANT SPEC, INSTALL LOCATION AND HEIGHT
6 AND ALL REQUIRED SWITCHING WITH LANDLORD.
REFLECTED CEILING PLAN
0 2' 4' 8' 16,
�N
THIS DRAWING, AND THE IDEAS,
IESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC_ AND ARE NOT TO BE
ISED OR REPRODUCED IN WHOLE, OR
IN PAWL WITHOUT➢IE WRITTEN
CONSENT OFSCHOTT DESIGN.
N
C)
CD
CD
M
Z
1^�
O
J
LJJ
L
W
�
U
LU
U
W
H
tn��Q
N
L
CL
C)
ELJ
Q
r—
LLU
L
ISSUE
DATE
DESCRIPTION
03.22.19
REVIEW SET
04.02.19
CONSTRUCTION SET
REVISIONS
ARK
DATE
DB
DESCRIPTION
PROJECT NUMBER
2018.429
PROD. MGR DRAWN BY
AS SLF
4TH FLOOR
REFLECTED
CEILING PLAN
Al21