HomeMy WebLinkAboutA121 Reflected Ceiling PlanLEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'A, LED ❑ LIGHT FIXTURE, 2'x2', LED LIGHT FIXTURE, I'x4', LED, ® INDIRECT CAN LIGHT FIXTURE SUSPENDED FROM DECK; CONFIRM EXACT SPEC, LOCAITON AND INSTALL HEIGHT WITH LANDLORD ® LIGHT FIXTURE, PENDANT NIL NIGHT LIGHT ® EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE JA ® EMERGENCY LIGHT EMERGENCY LIGHT FIXTURE FIXTURE $N LIGHTSWRCH a LIGHTSWRCH $N3 LIGHT SWITCH, &WAY $3 LIGHT SWITCH, &WAY LIGHT SWITCH, DIMMER $D LIGHT SWITCH, DIMMER AND $NP SWITCH, PROJECTOR SCREEN $p SWITCH, PROJECTOR SCREEN $NG SWITCH, GARBAGE DISPOSAL $G SWITCH, GARBAGE DISPOSAL (ABOVE COUNTERTOP) $NE SWITCH, EXHAUST FAN $G SWITCH, EXHAUST FAN i — UGHTCIRCUIT ...... LIGHTCIRCUIT CEILING GRID, SUSPENDED, 7x2' GYPSUM BOARD CEILING ■ EXPOSED TO DECK MRELOCATED DIFFUSER, LAY IN. 2 X7 RELOCATED DIFFUSER, LAY -IN, l'x4' RELOCATED ® DIFFUSER, LAY IN. WNW ® EXHAUST FAN, 2'x2' CEILING GRID, _r_ SUSPENDED, Zx2' ® EXISTING DIFFUSER, LAYJN, 2x2' ® EXISTING DIFFUSER, LAYJN, l'x4' m EXISTING DIFFUSER, LAYJN, 4"X4' XEXISTING EXHAUSTFAN, 7x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. RELOCATE DIFFUSERS L , .MECHANICAL DIFFUSER RELOCATION RELEASED FOR CONSTRUCTION `REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/07/19 AREA NOT IN CONTRACT ❑ AREA OF WORK GENERAL NOTES PROVIDE NEW BUILDING STANDARD 2X2CEILING GRID AND TILE INSTALLED AS HIGH AS POSSIBLE FOR UNIFORM HEIGHT ON ENTIRE 4TH FLOOR. CONFIRM EXACT SPECIFICATIONS WITH LANDLORD. 2. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMAANDIBC. LIGHTS CONNECTEDTOAN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 507,OF THE LIGHTING WILL BE REPLACED WITH NEW, SOASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 4. UNLESS OTHERWISE NOTED, ALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 5. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN. 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND 15 OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES, 2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING COMPLETED. FILTERS MUST BE CHANGED AT CLOSE OF PROJECT AND ALL THERMOSTATS MUST BE CALIBRATED AND AIR BALANCED, PROVIDE REPORT TO OWNER. PLAN NOTES itJl CLEAN ALL EXPOSED SURFACES AND PREPARE FOR DRYFALL PAINT AS NOTED ON PLAN PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING I N ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE RIGID SPIRAL DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA. R02 TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 5' WIDE DRYWALL BULKHEAD EXTENDING FROM 2' BELOW HEIGHT OF CEILING GRID TO DECK. TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL, R03 DESIGN INTENT 15 FOR CEILING GRID AND TILE TO STOP IN THIS LOCATION. SECURE GRID AS REQUIRED FOR FUTURE EXPANSION OF CEILING IN NORTH END OF SPACE, OCONFIRM WITH LANDLORD ON EXACT LOCATION AND INSTALL R04 HEIGHT OF LINEAR FIXTURES IN THIS AREA. 6CONFIRM EXACT PENDANT SPEC, INSTALL LOCATION AND HEIGHT 6 AND ALL REQUIRED SWITCHING WITH LANDLORD. REFLECTED CEILING PLAN 0 2' 4' 8' 16, �N THIS DRAWING, AND THE IDEAS, IESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC_ AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PAWL WITHOUT➢IE WRITTEN CONSENT OFSCHOTT DESIGN. N C) CD CD M Z 1^� O J LJJ L W � U LU U W H tn��Q N L CL C) ELJ Q r— LLU L ISSUE DATE DESCRIPTION 03.22.19 REVIEW SET 04.02.19 CONSTRUCTION SET REVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2018.429 PROD. MGR DRAWN BY AS SLF 4TH FLOOR REFLECTED CEILING PLAN Al21