HomeMy WebLinkAboutE111 Electrical PlanLEGEND NEW CONSTRUCTION D@N POWER OUTLET, DUPLEX N POWER OUTLET, QUADRUPLEX ® JUNCTION BOX MOUNTED OCEILING JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, OPEN P PROVIDE JUNCTION BOX ABOVE CEILING FOR POWER POLE CONNECTION. POWER POLE BY OTHERS. FLOOR BOX WITH POWER 70=19 AND DATA, FLUSH MOUNTED FLOOR BOX WITH ®1@ JUNCTION BOX AND DATA, FLUSH MOUNTED DATA/COMMUNICATION KIN OUTLET (PROVIDE BOX AND PULL STRING ONLY) DED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE GENERAL NOTES EXISTING TO REMAIN I. TENANTS FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. POWER OUTLET, DUPLEX POWER OUTLET, 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL QUADRUPLEX NEW DEVICES AND FACE PLATES TO BE WHITE. RELOCATE EXISTING Q JUNCTION BOX OUTLETS AT SAME HEIGHT AS NEW IF THERE IS A VARIANCE. CEILING MOUNTED JUNCTION BOX 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH BOX, BLANK COVER PLATE TENANT/OWNER REGARDING POWER LOCATIONS TO Q ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR Q BOX,OPEN MAG-LOCKS. ALL ELECTRICAL AND MAGNETIC HARDWARE AND CONNECTIONS TO BE COMPLETED BY TENANTS SECURITY VENDOR. P POWER AND DATA POLE ❑ 4. ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING, ELECTRICAL FLOOR BOX WITH POWER CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL Fq AND DATA, FLUSH WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MOUNTED MUST COMPLY WITH ALL APPLICABLE CODES. FLOOR BOX WITH FJ 11 JUNCTION BOX AND DATA, FLUSH MOUNTED b DATA/COMMUNICATION OUTLET RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/07/19 PLAN NOTES LUl PROVIDE POWER AS REQUIRED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. E02 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/ WALL FOR TENANTS MICROWAVE, CENTERED AT 24' A.F.F. PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED E03 TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH LANDLORD. MAREA NOT IN CONTRACT ELECTRICAL PLAN ❑ AREA OF WORK mr6ml0 2' 4' 8' l �N THIS DRAWING, AND THE IDEAS, IESIG ES AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC_ AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUTTHE WRITTEN CONSENT OF SCHOTT DESIGN. CV O ch � M V L O J LiJ w LU � U LU U W H N = Q 1< Z w Q� 07 I= .- w ISSUE DATE DESCRIPTION 03.22.19 REVIEW SET 04.02.19 CONSTRUCTION SET EVISIONS ARK DATE DB DESCRIPTION PROJECT NUMBER 2018.429 PROD. MGR DRAWN BY AS SLF 4TH FLOOR ELECTRICAL PLAN E111