SUITE 405 CODE SUMMARY
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY OFFICE SPACE
PREVIOUS USE OF SPACE BUSINESS)
OCCUPANCY CLASSIFICATION
B(USINESS)
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
VARIES SF/FLOOR
X
1 8 STORIES
=
214,546 SF
TOTAL PROJECT AREA
3,142 SF
OCCUPANCY CALCULATIONS
SPACE TYPE
AREA
SF PER OCCUPANT
OCCUP LOAD
GEN. OFFICE
3,142 SF
100
32
TOTAL OCCUPANTS IN PROJECTAREA 32
NUMBER OF EXITS
REQUIRED: I PROVIDED: I
SPRINKLER SYSTEM(YES/NO)
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
22,478 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REELECTED CEILING PLAN)
BUILT BEFORE 19782
NO
BUILDING CONSTRUCTION TYPE
III
LEGEND
EP EXISTING ELECTRICAL PANEL LOCATION
EJ( EXISTING EXIT. BUILDING STAIR LOCATION
FEI FF FIRE EXTINGUISHER
® EXITSIGN - LED EDGE LIT
— — — TRAVEL DISTANCE
O NIGHT LIGHT/EMERGENCY LIGHTING
wLeL NIGHT LIGHTS ARE HOOKED UP TO
UILDINGS EMERGENCY GENERATOR)
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/07/19
2
3
4
5
6
7
8
9
10
11
12
13
SUITE 430 CODE SUMMARY
SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY OFFICE SPACE
PREVIOUS USE OF SPACE BUSINESS)
OCCUPANCY CLASSIFICATION
B(USINESS)
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
VARIES SF/FLOOR
X
1 8 STORIES
=
214,546 SF
TOTAL PROJECT AREA
3,373 SF
OCCUPANCY CALCULATIONS
SPACE TYPE
AREA
SF PER OCCUPANT
OCCUP LOAD
GEN. OFFICE
3,373 SF
100
34
TOTAL OCCUPANTS IN PROJECT AREA 34
NUMBER OF EXITS
REQUIRED:I PROVIDED:I
SPRINKLER SYSTEM(YES/NO)
YES- EXISTING TO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
22,478 SF
ACCESSORY AREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 19782
NO
BUILDING CONSTRUCTION TYPE
I-B
LIFE SAFETY NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. FROM DE ALA RM NOTIFICATION APPLIANCES (HORNS/STROB ES),
EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AN D ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS ATTHEIR EXPENSE.
ELECTRICIAN TO RELOCATE EXISTING. ANY NEW FIXTURES TO BE
ADDED BY OWNER'S LIFE SAFETY VENDOR ONLY,
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER. FIRE EXTINGUISHERS PROVIDED BY
TENANT.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM, SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM,
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
nnrNnnFNTc WITH ME CTATF AN n I nrA I AI ITHnaITIFC H A VIM
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DEFAILS.
L2. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT
SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS
REQUIRED TO MEET ALL LOCAL AND STATE CODES.
AREA NOT IN CONTRACT LIFE SAFETY PLAN
❑0 4
AREA OF WORK %?==MmI
>N
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT
TO BE
USED OR REPRODUCED IN WHOLE,
OR
IN PART, WIMOUT ME WRITTEN
CONSENT OF SCHOTT DESIGN.
N
O
cY)
0
M
v
LO
O
J
�
W
h
W
�
V
LU N
U
WIlmmmmRIIIIIIIIIIR
N all
N
Q
C
0
ry
Z
LLJ
Q2
07
r
LU
C �
ISSUE
DATE
DESCRIPTION
03.22.19
REVIEW SEF
04.02.19
CONSTRUCTION SEF
REVISIONS
ARK
DATE
DB
DESCRIPTION
PROJECT NUMBER
2018.429
PROD. MGR DRAWN BY
AS SO
4TH FLOOR
LIFE SAFETY
L100