Loading...
HomeMy WebLinkAboutA111 Door Schedule & Arch Floor PlanDOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM. TYPE MATERIAL FINISH TYPE MATERIAL FINISH 01 3'-0"X8'-0" (PAIR) D3 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING EL, CR, CL PP 04 3'-0'x8'-0 D2 SOLID CORE BIRCH VNR. GRAHAM'x13/4' ARK WALNUT ITIMELY ALUMATONE PP, CL RI 05 3'-0"x8'-0"x13/q' DI SOLID CORE BIRCH VNR. GRAHAM ARK WALNUT ITIMELY ALUMATONE SL Ob 3'-0'x8'-0'Xl3/q' DI SOLID CORE BIRCH VNR. GRAHAM ARK WALNUT ITIMELY ALUMATONE PS 07 3'-d'x8'-0'X13/4' DI SOLID CORE VNR. GRAHAM ARK WALNUT I TIMELY ALUMATONE PIS 08 3'-0'X8'-0'x13/4' DI SOLID CORE VNR. GRAHAM ARK WALNUT IBIRCH TIMELY ALUMATONE P$ 09 3'-0"x8'-0"x13/q' D2 SOLID CORE BIRCH VNR. GRAHAM ARKWALNUT ITIMELY ALUMATONE P$ 10 3'-0"X8'-G' D4 HERCULITE GLASS SYSTEM DRYWALL WRAPPED OPENING EL, CR, CL, PP 12 3'-0"X8'-0'X13/q' DI SOLID CORE BIRCH VNR. GRAHAM DARK WALNUT F3 TIMELY ALUMATONE P$ 13 3'-0'x8'-0 DI SOLID CORE BIRCH VNR. GRAHAM'x13/4' ARK WALNUT I TIMELY ALUMATONE PS 14 3'113/q' D1 SOLID CORE BIRCH VNR. GRAHAM ARK WALNUT I TIMELY ALUMATONE P$ DOOR/FRAME TYPES 3'-0 D1 D2 2 STANLESS STEL TOP RAIL 1/2"TEMPEREOGIAA \ ROVQ SEE ONE PULLON \ EACH DOOR (TOTAL COUNT )TOTAL UM 2LA5 IN NOTED IN RE.AARFS 2STAINLESS STEEL TOP RAIL m IAA YI�II F1 F2 F4 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/07/19 PATCH PANELS FTYP. ATTOPAND BOTTOM OF Ei 1a TEMPERED GLASS 0 p\ EE \ PROVIDE ONE PULL ON EACHSIDEOFDOOR \ )TOTAL COUNT 2), AS NOTED IN REMARKS D3 5.8. EQ. EQ. F3 y/SFTEMP92® GLASS; BuncLAZED HARDWARE LEGEND ARCHITECTURAL LEGEND RI. SEE FRAME TYPE F4, WHICH IS TO BE CENTERED IN NORTHWEST WALL OF NEW CONSTRUCTION EXISTING TO REMAIN CONFERENCE 404 AS SHOWN ON PLAN. HEIGHT OF FRAME TO MATCH HEIGHT OF ADJACENT DOOR FRAME- w m WALL WALL HARDWARE LEGEND T ® PARTIAL HEIGHT WALL BTTSD PARTIAL HEIGHT WALL �u WINDOW/SIDELIGHT T~rt WINDOW/SIDELIGHT CL CLOSER CH COATHOOK CR CARD READER BY TENANT C N I.. ( ) DOOR AND FRAME (SEE DOOR SCHEDULE) 77 DOOR AND FRAME EL ELECTROMAGNETIC LOCK (PER IBC 2012) ES ELECTRIC STRIKE BY TENANT )N.LC.) H HOLD OPEN 0 KICK STOP WALL TYPES OL OFFICE LOCKSEi PP PUSH/PULL-PROVIDE ONE POST MOUNT PULL ON EACH SIDE OF DOOR TOTAL COUNT 2). ROCKWOOD #RM3302. 628 CLEAR ANODIZED FINISH, 4' LONG NOTE: PS PASSAGE LATCHSET PV PIVOT HINGE ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE F UNLESS OTHERWISE NOTED. SL STOREROOM LOCKSET PROVIDE MOISTURE RESISTANT/ GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. DOOR/FRAME NOTES ARE NECESSARILY LY USED ON THIS NOT ALL CT. ALLREF TYPERTO REFLECTED PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. CEILING Wl WALL WITH INSULATION I. PROVIDE NEW BUILDING STANDARD DOORS AND FRAMES AS NOTED 35/B"MErALSTDDS AT 16"O-G; ! 1 ON DOOR SCHEDULE. PRE -MACHINE NEW DOORS FOR CYLINDRICAL LOCKSETS. ONE LAYER OF %'TYPE "X" GYPSUM BOARD EACH SIDE; 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. FOR EXTEND WALL TO UNDERSIDE OF CEILING; NEW DOOR HARDWARE. PROVIDE GRADE 2 MINIMUM BUILDING FIBERGLASS SOUND BAIT INSULATION INSIDE STANDARD. PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK WALL AND 2-0" EACH SIDE OF WALL ABOVE AND LATCHSETS. CEILING 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL DEMISING WALLTO DECK CORNERS UNLESS OTHERWISE NOTED ON PLAN. W2 WITH INSULATION 3% METAL STUDS AT I6"O.C; 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. ONE LAYER OF%'TYPE'X'GYPSUM BOARD EACH SIDE; 6.TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, EXTEND WALLTO UNDERSIDE OF DECK; PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED FIBERGLASS SOUND BATT INSULATION INSIDE ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES, WALL ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS, WS HEIGHT WALL PARTIAMETAL ]. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: 3S/B"METAL STUDS AT 16" O.C.; STUDS • 7'-0"HT. TO HAVE 3 HINGES ONE LAYER OF %" TYPE "X"GYPSUM BOARD • GREATER THAN 7'-0" IN HT. TO HAVE 4 HINGES EACH SIDE; • FINISH TO MATCH HARDWARE SET SEE DETAILS FOR WALL HEIGHT; PROVIDE I"STEEL PIPE ANCHORS INTO B. PROVIDE(1) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE CONCRETE FLOOR FOR SUPPORT AS NOTED. REQUIRED 9. PROVIDE WALL STOP )FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. GENERAL NOTES I. EXISTING SPACE IS IN WHITEBOX CONDITION; NO DEMOLITION REQUIRED. 2. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 3. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS, 4. CONFIRM THAT ALL EXISTING WALLS ARE FULLY INSULATED, IF NOT, PROVIDE NEW INSULATION AS REQUIRED. WALL THICKNESS n METAL STUD EXISTING WIN MULLION PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT WALL AT MULLION DETAIL AI I I NOT TO SCALE PLAN NOTES UAOt ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET A02 TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. OPROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A03 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WTH LANDLORD. AD4 SUPPORT COUNTER AS REQUIRED WITH CENTERLINE BRACKET'S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT, CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. A05 EXISTING COLUMN TO REMAIN RAW UNFINISHED CONCRETE. CLEAN AS REQUIRED. A06 IF REQUIRED, EXTEND EXISTING DRYWALL TO DECK IN AREA OF EXPOSED CEILING. SEE REFLECTED CEILING PLAN FOR EXACT LOCATION OF EXPOSED CEILING. A07 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xq', PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WTH LANDLORD PRIOR TO INSTALLATION. A08 FIRE EXTINGUISHER TO BE LOCATED WITHIN SINK CABINE. CONTRACTOR TO PROVIDE AND INSTALL CODE COMPLIANT LABEL ON CABINET FACE, INDICATING FIRE EXTINGUISHER LOCATION. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. PD1 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. P02 PROVIDE COPPER WATER LINE (PLOYTUBE IS NOT PERMITTED) FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH LANDLORD. ® AREA NOT IN CONTRACT ARCHITECTURAL PLAN ❑ A0 2' 4' 8' 16' AREA OF WORK u mmm THIS DRAWING, AND THE IDEAS, IESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC.. AND ARE NOT TO BE ISED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT TH E WRITTEN CONSENT OF SCHOTT DESIGN. wim N CD M O •M� V �y W Z LJ•l CD J LJJ 1n 2 W Qf� UwNU W H B = v> N Q Z LcLjJ Q_ L Yw � W SSUE DATE DESCRIPTION 03.22.19 REVIEW SET 04.02.19 CONSTRUCTION SET EVISIONS ARK DATE I DO DESCRIPTION PROJECT NUMBER 2018.429 PROD. MGR DRAWN BY AS SLF 4TH FLOOR DOOR SCHEDULE 8 ARCH. FLOOR PLAN A111