HomeMy WebLinkAboutHVAC PLAN + NOTES A201IN CEILING
10 NOW HEAT
2 TON
AIR HANDLER
2 NTYPICAL
TO SCALE
'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
EXISTING MAIN SUPPLY
BRANCH DUCT
REROUTE EXISTING SUPPLY
BRANCHIR-EX DUCT
TYPICAL EXISTING SUPPLY
DISCHARGE DUCT
C
TYPICAL EXISTING SUPPLY
INLET DUCT
LEGEND
® DIFFUSER LAY IN, eS9'
® DIFFUSER, LAY -IN, I'REP
m DIFFUSER. LAY IN, 4xb'
MECHANICAL NOTES
I. DIFFUSER LOCATIONS ARE SHOWN ON PLAN FOR REFERENCE ONLY,
CONTRACTOR IS TO PEACE LOCATION OF DIFFUSERS AND RETURN
AIR GRILLES AS REG UIR ED BY CODE.
2. FIRE STOP ANY EXISTING DECK PEN EFRATIONS AS REQUIRED.
3. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL
DESIGN, ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT
CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT
BEFORE INSTALLING.
4, ALL HVAC SYSTEMS TO BE INSTALLED IN CONFORMANCE WITH
STATE AND LOCAL BUILDING CODES, LOCAL FIRE DEPARTMENT
REGULATIONS, AND THE LATEST EDITATION OF SMACNA AND
ASHRAE STANDARDS.
5. ALL DUCTWORK,HANGERS, SUPPORTS AND FASTENERS TO BE
INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE
SMACNA MANUAL.
6. INSTALL PLENUM RATED LOW VOLTAGE CONTROL WIRING FOR
THERMOSTATS, SENSORS AND DUCT SMOKE DEFECTORS (IF
APPLICABLE).
]. PROVIDE MANU BALANCING DAMPERS FOR ALL SUPPLY AIR
BRANCH LINES.
B. MAXIMUM FLEXIBLETERMINARONS TO SUPPLY AIR DIFFUSERS IS B'-0"
SUPPORT FLEXIBLE DUCT, PER CODE.
■ AREA NOT IN CONTRACT
❑ AREAOFWORK
.40. / DAMPER
TYPICAL EXISTING RELOCATED
PERIMETER SLOT DIFFUSER
NOTE. TO BE USED ONLY FOR PROJECTS THAT REQUIRE
RELOCATION AND REUSE OF EXISTING AIR DEVICES FROM
EXISTING EQUIPMENT AND DUCTWORK THAT REMAINS.
HVAC PLAN MECHANICAL DIFFUSER RELOCATION
SCALE: I /B" = I'-0" NOT TO SCALE
'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
Citv of Camel
�N;Mv�tD
DATE: 08/07/19
a
E
z
Z
L7
N
0
—
J
Q
H
z
O
[L
z -
LD m--
yCi n
w ON 2a cc
A
O
tu
i�
ED
ED
61
I
Z
K
O
Z
AD
Be
w
0
a-
w
o
O
ro
CJ
O
O
f
b
T
m
z
r c6
p
ED
EA
V ED
w
CF
u O
Q
O
Cop
O
N
LD
MID
O + N
U O
W
i
L d �
�Q�VE
++ rd U
W
ZO
a—
IEF uS',EUrigiiix
GIST['i•E'..
`.`
19600042
IT
TE OF
$
f 14
/9 �S
/ I
JAL I1I
HVAC PLAN +
NOTES
A201
ALL DESI4xgconCEPQAPPANGEMENTS AND PLANS
INDICATED OR REPRESENTED BYTHESE ORAWINCSAPE
OWNED BY PARAUELOESexeaaDP, INC. AND SHALL
NOT
BE USED BY OR DISCLOSED ToMY PERSON HEM
ORCORP. FOR ANY REASON WHATSOEVERWIiHOUF THE
WR1M
CONSENT OF PARALLEL DESIGN GROUP INC
CONTRACTORS SHALL VERIFY AN D BE RESPO NSIBLE FOR
AL
DIN Ex SO xS ON TE JOB SITE PARALLEL DESIGN
CREPIN M ACTAED OF MYE5xOWN!
OROUPINGNUS FRO
LET BE MTHE DINEN9 NSSHOWN ONT
PLAN.