Loading...
HomeMy WebLinkAboutHVAC PLAN + NOTES A201IN CEILING 10 NOW HEAT 2 TON AIR HANDLER 2 NTYPICAL TO SCALE 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION EXISTING MAIN SUPPLY BRANCH DUCT REROUTE EXISTING SUPPLY BRANCHIR-EX DUCT TYPICAL EXISTING SUPPLY DISCHARGE DUCT C TYPICAL EXISTING SUPPLY INLET DUCT LEGEND ® DIFFUSER LAY IN, eS9' ® DIFFUSER, LAY -IN, I'REP m DIFFUSER. LAY IN, 4xb' MECHANICAL NOTES I. DIFFUSER LOCATIONS ARE SHOWN ON PLAN FOR REFERENCE ONLY, CONTRACTOR IS TO PEACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REG UIR ED BY CODE. 2. FIRE STOP ANY EXISTING DECK PEN EFRATIONS AS REQUIRED. 3. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN, ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT BEFORE INSTALLING. 4, ALL HVAC SYSTEMS TO BE INSTALLED IN CONFORMANCE WITH STATE AND LOCAL BUILDING CODES, LOCAL FIRE DEPARTMENT REGULATIONS, AND THE LATEST EDITATION OF SMACNA AND ASHRAE STANDARDS. 5. ALL DUCTWORK,HANGERS, SUPPORTS AND FASTENERS TO BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA MANUAL. 6. INSTALL PLENUM RATED LOW VOLTAGE CONTROL WIRING FOR THERMOSTATS, SENSORS AND DUCT SMOKE DEFECTORS (IF APPLICABLE). ]. PROVIDE MANU BALANCING DAMPERS FOR ALL SUPPLY AIR BRANCH LINES. B. MAXIMUM FLEXIBLETERMINARONS TO SUPPLY AIR DIFFUSERS IS B'-0" SUPPORT FLEXIBLE DUCT, PER CODE. ■ AREA NOT IN CONTRACT ❑ AREAOFWORK .40. / DAMPER TYPICAL EXISTING RELOCATED PERIMETER SLOT DIFFUSER NOTE. TO BE USED ONLY FOR PROJECTS THAT REQUIRE RELOCATION AND REUSE OF EXISTING AIR DEVICES FROM EXISTING EQUIPMENT AND DUCTWORK THAT REMAINS. HVAC PLAN MECHANICAL DIFFUSER RELOCATION SCALE: I /B" = I'-0" NOT TO SCALE 'REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes Citv of Camel �N;Mv�tD DATE: 08/07/19 a E z Z L7 N 0 — J Q H z O [L z - LD m-- yCi n w ON 2a cc A O tu i� ED ED 61 I Z K O Z AD Be w 0 a- w o O ro CJ O O f b T m z r c6 p ED EA V ED w CF u O Q O Cop O N LD MID O + N U O W i L d � �Q�VE ++ rd U W ZO a— IEF uS',EUrigiiix GIST['i•E'.. `.` 19600042 IT TE OF $ f 14 /9 �S / I JAL I1I HVAC PLAN + NOTES A201 ALL DESI4xgconCEPQAPPANGEMENTS AND PLANS INDICATED OR REPRESENTED BYTHESE ORAWINCSAPE OWNED BY PARAUELOESexeaaDP, INC. AND SHALL NOT BE USED BY OR DISCLOSED ToMY PERSON HEM ORCORP. FOR ANY REASON WHATSOEVERWIiHOUF THE WR1M CONSENT OF PARALLEL DESIGN GROUP INC CONTRACTORS SHALL VERIFY AN D BE RESPO NSIBLE FOR AL DIN Ex SO xS ON TE JOB SITE PARALLEL DESIGN CREPIN M ACTAED OF MYE5xOWN! OROUPINGNUS FRO LET BE MTHE DINEN9 NSSHOWN ONT PLAN.