HomeMy WebLinkAboutLIFE SAFETY A001LEGEND
EP EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT- BUILDING EXIT LOCATION
FE FIRE EXTINGUISHER
q®� EXIT SIGNAGE
LID EMERGENCY LIGHTING
NL NIGHT LIGHT/EMERGENCY LIGHTING
]NIGHT LIGHTS ARE HOOKED UP TO
BUILDING EMERGENCY GENERATOR]
]SEE A200 FOR LOCATIONS]
LIFE SAFETY PLAN
SCALE:NOT TO SCALE
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 08/07/19
CODE SUMMARY
SCOPE OF WORK:
OFFICE SPACE BUILD -OUT REMODEL TO PREVIOUSLY BUILT -OUT
OFFICE.
OCCUPANCY CLASSIFICATION:
BIUSINESSI
CHANGE OF OCCUPANCY CLASS:
NO
TOTAL BUILDING AREA:
±13,620 SF/FLOOR X 2 STORIES = 27,239 GROSS SF
TOTAL AREA ON FLOOR:
13,620 SQ.PT.
TOTAL PROJECT AREA:
4,995 SQ.FT.
OCCUPANCY CALCULATIONS
SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD
GENERAL OFFICE 4,995 100 49
TOTAL OCCUUANTS IN PROJECT AREA
NUMBER OF REQUIRED EXITS:
2
SPRINKLER SYSTEM (YES/NOJ:
NOT EXISTING - NEW SYSTEM BEING INSTALLED IN TENANT SUITE
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED)
N/A
APPLICABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2014 INDIANA BUILDING (2012 IBC, ASCE-7-2010)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
20141NDIANA MECHANICAL CODE (2012 ]ARC WITH STATE
AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 EC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CHI ]-ACCESSIBILITY, ANSI A-] 17.1
STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASTRAL 90.1-2007)
WITH INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
GENERAL NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED
IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN
ON PLAN ARE FOR REFERENCE ONLY,
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES],
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY
TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING
CODE, INTERNATIONAL FIRE CODE, NFPA).
3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION
OF THE FIRE SPRINKLER SYSTEM.
4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNER/LANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
5. REFER TO SHEET A 100 FOR WALL TYPE AND CONSTRUCTION
DETAILS
6. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO BE NEW.
❑ AREA OF WORK
■ AREA NOT IN SCOPE
a
E
Z
z
L�
m —
Q
—
J
a =
H
z
O
z -
O m - -
yCi n
w ON 2a cc
Rat RE 0
o
tu
3
Z
S-
k
O
Z
Be
w
0
d
LLJ0
£of
e
rn
m
_
W
o
3 EachCIS
p
w
Ass
u O
a
w
Ociff
N
LD
L �
O + N
O
r
�mJ Safes
L d �
r E
v
V E
.0
++ Cd U
W
Z
t—
['i•E'..
ey GISTZZ
`.N
19600042
IT
TE OF
f 14RD
/9
I
u\\
LIFE SAFETY
A001
ALL DEEIGxs,CONCEFUGARRANGEMExb AND PLANS
INDICATED OR REPRESENTED BYTHESE DRAWINCSAPE
OWNED BY PABALLELDEsoNGROUP INC. ADD SHALL
NOT
BE USED BY OR DISCLOSED ToMY PERSON REM
ORCORP. FOR ANY REASON WHATSOEVERWIiHOUT THE
WR1M
CONSENT OF PARALLEL DESIGN GROUP INC
CONTRACTORS SHALL VERIFY AN D BE RESPO NSIBLE FOR
ALL
DIM Ex SO xS ON TE JOB SITE PARALLEL DEs6ry
GROUPING. MUST BE NO➢ FI ED OF MY DIECREPANCI ES
ORVARIANnoxsFRO MTHE DINEN90NSSHOWNONTHE
PUN.