HomeMy WebLinkAboutLIFE SAFETY A001LEGEND EP EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT- BUILDING EXIT LOCATION FE FIRE EXTINGUISHER q®� EXIT SIGNAGE LID EMERGENCY LIGHTING NL NIGHT LIGHT/EMERGENCY LIGHTING ]NIGHT LIGHTS ARE HOOKED UP TO BUILDING EMERGENCY GENERATOR] ]SEE A200 FOR LOCATIONS] LIFE SAFETY PLAN SCALE:NOT TO SCALE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: 08/07/19 CODE SUMMARY SCOPE OF WORK: OFFICE SPACE BUILD -OUT REMODEL TO PREVIOUSLY BUILT -OUT OFFICE. OCCUPANCY CLASSIFICATION: BIUSINESSI CHANGE OF OCCUPANCY CLASS: NO TOTAL BUILDING AREA: ±13,620 SF/FLOOR X 2 STORIES = 27,239 GROSS SF TOTAL AREA ON FLOOR: 13,620 SQ.PT. TOTAL PROJECT AREA: 4,995 SQ.FT. OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD GENERAL OFFICE 4,995 100 49 TOTAL OCCUUANTS IN PROJECT AREA NUMBER OF REQUIRED EXITS: 2 SPRINKLER SYSTEM (YES/NOJ: NOT EXISTING - NEW SYSTEM BEING INSTALLED IN TENANT SUITE FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2014 INDIANA BUILDING (2012 IBC, ASCE-7-2010) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 20141NDIANA MECHANICAL CODE (2012 ]ARC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETY CODE 2014 INDIANA FIRE CODE (2012 EC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CHI ]-ACCESSIBILITY, ANSI A-] 17.1 STANDARD, ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGY CODE 2010 INDIANA ENERGY CONSERVATION CODE (ASTRAL 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. GENERAL NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY, 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES], EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 5. REFER TO SHEET A 100 FOR WALL TYPE AND CONSTRUCTION DETAILS 6. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO BE NEW. ❑ AREA OF WORK ■ AREA NOT IN SCOPE a E Z z L� m — Q — J a = H z O z - O m - - yCi n w ON 2a cc Rat RE 0 o tu 3 Z S- k O Z Be w 0 d LLJ0 £of e rn m _ W o 3 EachCIS p w Ass u O a w Ociff N LD L � O + N O r �mJ Safes L d � r E v V E .0 ++ Cd U W Z t— ['i•E'.. ey GISTZZ `.N 19600042 IT TE OF f 14RD /9 I u\\ LIFE SAFETY A001 ALL DEEIGxs,CONCEFUGARRANGEMExb AND PLANS INDICATED OR REPRESENTED BYTHESE DRAWINCSAPE OWNED BY PABALLELDEsoNGROUP INC. ADD SHALL NOT BE USED BY OR DISCLOSED ToMY PERSON REM ORCORP. FOR ANY REASON WHATSOEVERWIiHOUT THE WR1M CONSENT OF PARALLEL DESIGN GROUP INC CONTRACTORS SHALL VERIFY AN D BE RESPO NSIBLE FOR ALL DIM Ex SO xS ON TE JOB SITE PARALLEL DEs6ry GROUPING. MUST BE NO➢ FI ED OF MY DIECREPANCI ES ORVARIANnoxsFRO MTHE DINEN90NSSHOWNONTHE PUN.