HomeMy WebLinkAbout126-10011-Mulligan-Foundation PlanUP DN ALIGN TOP OF SILL TRACK / RISER FLUSH WITH FLOOR FINISH. *NOTE:SGD SILL, TRACK & REQ. RECESS MAY VARY FROM THIS DETAIL COORDINATE WITH YOUR SPECIFIC SGD MFR. & INSTALLER FOR PROPER RECESS DEPTH & WIDTH. BASEMENT 4" THICK MIN. CONC. SLAB ON 6 MIL. VAPOR BARRIER ON 6" THICK MIN GRAVEL BASE UNEXCAVATED 4" THICK MIN. CONC. SLAB ON 6" THICK MIN GRAVEL BASE outer 4" of poured wall to support garage slab ht basement pour height 10' 1'-0"1'-0" 6'-1" 48'-10" 6'-7" 7'-1" 2'-10"19'-8" 3'-4" 45'-6" 16'-8" 4'-3" 10'-2" 6'-7" 6'-4" 7'-2" 11'-0" 3'-2" 13'-6" 34'-6" 4'-3" 5'-8" 4'-3" 13'-6"9'-8" 8'-2" 7'-1"2'-2" 23'-0" 62'-2"5'-6"5'-6" 22'-4"38'-8" 6'-8" 6'-1" 1'-0" 1'-0"12'-0" 5'-2" 9'-3" 1'-8" 10'-2" 5" 21'-6" 9" 9'-6" 2'-0" 15'-3"17'-1 1/2"3'-1" 2'-1 1/2" 2'-1 1/2" 16'-5" 1'-7" 16'-5" 2'-1 1/2" 8'-3 3/4"3'-6" 5'-4 1/2" 1'-6 1/4" 13'-7 1/2" 5'-0"18'-7 3/4"PROVIDE GAS 1'-3" 19'-10"1'-7" 12'-10" 2'-0" 4'-11" 2'-0"1'-0"1'-0"29'-6"87'-4" 11'-10 1/2"3'-10"floor drain sump and grinder locations tbd 2'-4"3'-0"OUTER 4" OF FOUNDATION WALL TO STEP DOWN FOR BRICK VENEER UNEXCAVATED 4" THICK MIN. CONC. SLAB ON 6" THICK MIN GRAVEL BASE 2'-8 1/4" footing for columns per struct eng line of deck above WATERSUPPLY SEWERLINEfloor outlet location tbd 1 4.1 _______ 1 4.1 _______ 3 4.1 _______ 4 4.1 _______ 2 4.1 _______ 7 4.1 _______ STD WALL SECTION SITE RETAINING WALL PROVIDE GAS WH WH PROVIDE GAS 5 4.1 _______ RECESS 75'-9"guardrail as req'd 6 4.1 _______ 6 4.1 _______ AHU smArthur RutenbergHomesPLAN DISCLAIMERARTHUR RUTENBERG HOMES INC., THE DESIGNER, IS RESPONSIBLE FOR THE AESTHETIC DESIGN ONLY AS REPRESENTEDIN THESE DRAWINGS (PLANS), BUT NOT FOR ANY STRUCTURAL INFORMATION INCLUDED OR OMITTED. THE CONTRACTOR(BUILDER) IS RESPONSIBLE BOTH FOR CONFORMING THESE PLANS AND CONSTRUCTING THE RESIDENCE TO ALLAPPLICABLE FEDERAL, STATE, AND LOCAL BUILDING CODES, ORDINANCES, AND LAWS, INCLUDING BUT NOT LIMITED TOTHE FOLLOWING: EGRESS, FIRE SAFETY, TECHNICAL CODES, FLOOD ZONE CRITERIA, HURRICANE CODES, PRE-ENGINEERED TRUSSES, FRAMING MEMBERS, FLASHING, AND MOISTURE PROTECTION. BY USE OF THESE DRAWINGS THEOWNER, CONTRACTOR (BUILDER), AND SUBCONTRACTORS ACKNOWLEDGE AND AGREE TO THIS DISCLAIMER.ALL RIGHTS RESERVED ARTHUR RUTENBERG HOMES, INC.COPYRIGHT4 A CUSTOM PLAN FOR THE MULLIGAN RESIDENCEFOUNDATION PLAN PLAN: CUSTOM PLAN(BASEMENT)JOB: 126-10011 - DCI #S 1-58Christopher Scott Investments, Inc.736 Hanover Place, Suite 100FCarmel, IN 460322/20/19 - SHC4/9/19 - A - TK305/10/19 SWH - B06/14/19 DCC - C06/20/19 DCC - C207/23/19 WF3 - DTHE FOUNDATION PLANS REPRESENTED IN THESE DRAWINGS ARE INTENDED TO ESTABLISH GROUND FLOOR SURFACE CONDITIONS AND ESTABLISH VERTICAL ELEVATION DATA. ALL POTENTIAL BEARING LOCATIONS AND CONDITIONS ARE IN CONJUNCTION WITH FRAMING PLANS CONTAINED WITHIN THIS DRAWING SET AND ARE NOT INTENDED TO BE INTERPRETED AS STRUCTURAL ENGINEERED DRAWINGS. THE CONTRACTOR (BUILDER) SHALL ENSURE THAT THE STRUCTURE CONFORMS TO THOSE STANDARDS IN ALL RESPECTS INCLUDING STRENGTH, STRESSES, STRAINS, LOADS, CONNECTIONS AND STABILITY. REFER TO PLAN DISCLAIMER LOCATED ON THIS SHEET FOR ADDITIONAL STIPULATIONS AND REQUIREMENTS. FOUNDATION PLAN DISCLAIMER SLABS ON GRADE: 4" CONC. SLAB W/ FIBERMESH W/ 6 MIL VAPOR BARRIER OVER MECH. COMPACTED FILL. PROVIDE CONTROL JOINTS AS REQUIRED TREAT SOIL W/ TERMITE POISONING. SLAB NOTES: SEE SHEET 6 FOR SPECIFIC ELEV DETAILS. VERIFY DEPTH AND WIDTH OF SLAB RECESS AT ALL DOORS TO ACCOMMODATE PROPER ALIGNMENT WITH THRESHOLDS AND DOOR TRACKS WITH MFR. REQUIREMENTS IN RELATION TO FINISH FLOOR MATERIALS. ALL PIER LOCATIONS TO BE REVIEWED AND APPROVED BY A STRUCTURAL ENGINEER GENERAL NOTES: RECESSED FLOOR OUTLET (FULLY CONCEAL BELOW FLOOR LEVEL) #68-P W/COVER PLATE BY: THOMAS & BETTS, INC. OR EQUAL FLOOR OUTLET NOTE: 1/4" = 1'-0" FOUNDATION PLAN RECESS RECESS 08/07/19 Mike Sheeks