Loading...
HomeMy WebLinkAbout126-10011-Mulligan-Rear ElevMAIN LEVEL 0" MAIN LEVEL 0" UPPER LEVEL 11'-2 1/8" UPPER LEVEL 11'-2 1/8" T.O. FOOTING -11'-2 1/8" T.O. PL - UPPER LEVEL 20'-3 5/8" ACTUAL GRADE TO BE DETERMINED ON SITE VERIFY ACTUAL NUMBER OF STEPS AND HEIGHTS w/ FINAL GRADE, TYP APPROX T.O. ROOF 34'-9 11/16" T.O. FOUNDATION -1'-2 1/8" T.O. SLAB -10'-10 1/8" T.O. PLATE 10'-1 1/2" © 2019 ARTHUR RUTENBERG HOMES, INC. T.O. GARAGE SLAB -3'-9" KIDS LOUNGE 9'-11 1/4" BATH 4 12'-2 1/8" SHINGLE ROOF 12 12 12 12 12 12 12 12 12 12 12 12 12 12 5 12 10 1210:1210:12T.O. PL - GARAGE 8'-6 1/2" 10" SQ SOLID CEDAR COL W/ 1X8 BOTT TRIM & 1X6 TOP TRIM 8'-0" 8'-0"8'-0" 8'-0"13'-4"8'-0"8'-0"8" x 30" HDR AT 18'-2" LOUVER VENT 8" x 30" HDR AT 14'-3" LOUVER VENT 8'-0"2'-10"GARAGE KEY PAD LOC TBD8'-3 3/8"retaining wall - loc tbd wood brackets see dtl 1/6 1'-0" 2'-0"motorized screens per specs7'-3"fxd screen specs SMOOTH FINISH HARDIE PANEL OR EQ W/ 1X2 VERTICAL BATTEN STRIPS1'-1" 3'-1 1/4"3 1/2"4'-5 5/8"2 5/8" 3'-9 5/8"5 3/8"R4'-6" 2 5/8"7 1/4" 5 3/8"6 1/4" 1'-1 1/4" 5 1/2"3'-6" 6"4'-0" 1/4" = 1'-0" REAR ELEVATION smArthur RutenbergHomesPLAN DISCLAIMERARTHUR RUTENBERG HOMES INC., THE DESIGNER, IS RESPONSIBLE FOR THE AESTHETIC DESIGN ONLY AS REPRESENTEDIN THESE DRAWINGS (PLANS), BUT NOT FOR ANY STRUCTURAL INFORMATION INCLUDED OR OMITTED. THE CONTRACTOR(BUILDER) IS RESPONSIBLE BOTH FOR CONFORMING THESE PLANS AND CONSTRUCTING THE RESIDENCE TO ALLAPPLICABLE FEDERAL, STATE, AND LOCAL BUILDING CODES, ORDINANCES, AND LAWS, INCLUDING BUT NOT LIMITED TOTHE FOLLOWING: EGRESS, FIRE SAFETY, TECHNICAL CODES, FLOOD ZONE CRITERIA, HURRICANE CODES, PRE-ENGINEERED TRUSSES, FRAMING MEMBERS, FLASHING, AND MOISTURE PROTECTION. BY USE OF THESE DRAWINGS THEOWNER, CONTRACTOR (BUILDER), AND SUBCONTRACTORS ACKNOWLEDGE AND AGREE TO THIS DISCLAIMER.ALL RIGHTS RESERVED ARTHUR RUTENBERG HOMES, INC.COPYRIGHT6a A CUSTOM PLAN FOR THE MULLIGAN RESIDENCEREAR ELEVATION PLAN: CUSTOM PLANJOB: 126-10011 - DCI #S 1-58Christopher Scott Investments, Inc.736 Hanover Place, Suite 100FCarmel, IN 460322/20/19 - SHC4/9/19 - A - TK305/10/19 SWH - B06/14/19 DCC - C06/20/19 DCC - C207/23/19 WF3 - D· FLAT SOFFIT AT PERIMETER OF HOUSE UNLESS NOTED OTHERWISE. · VERIFY ALL WDW & DR ROUGH OPNGS W/ MFR SPECS. · LOCATE ALL PLUMBING STACKS BEYOND THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER CODE. · ROOF VENTS SHOWN FOR LOCATION PURPOSE ONLY. · NUMBER OF ROOF VENTS TO BE DETERMINED BY BUILDER. GENERAL NOTES: !! ATTENTION !! NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER TO COORDINATE THE INSTALLATION OF ALL WATER PROOFING METHODS NECESSARY TO PROVIDE A WATER TIGHT BUILDING ENVELOPE. REFER TO MFR. INSTALLATION RECOMMENDATION FOR ALL SELECTED WATERPROOFING MATERIALS, FLASHING, SEALERS AND AD-MIX COMPONENTS THE FRAMING PLANS REPRESENTED IN THESE DRAWINGS ARE INTENDED TO ESTABLISH PROPOSED FRAMING MEMBER LOCATIONS, FRAMING MEMBER DEPTH, POTENTIAL BEARING LOCATIONS AND ELEVATIONS, AND IS IN NO WAY INTENDED OR TO BE INTERPRETED AS STRUCTURAL ENGINEERED DRAWINGS. THE CONTRACTOR (BUILDER) SHALL ENSURE THAT THE STRUCTURE CONFORMS TO THOSE STRAINS, LOADS, CONNECTIONS, AND STABILITY. REFER TO PLAN DISCLAIMER LOCATED ON THIS SHEET FOR ADDITIONAL STIPULATIONS AND REQUIREMENTS. Framing PLAN DISCLAIMER ANY DUCT ROUTING AND HVAC EQUIPMENT SHOWN ON THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE BUILDER IS SOLELY RESPONSIBLE FOR COORDINATING ALL ASPECTS OF MECHANICAL INSTALLATION WITH ALL TRADES. THE BUILDER SHALL COORDINATE BETWEEN THE PRE ENGINEERED TRUSS MFR. AND/OR FRAMING REQUIREMENTS WITH THE MECHANICAL CONTRACTOR TO ENSURE ADEQUATE SPACE FOR DUCT ROUTING AND EQUIPMENT PLACEMENT AND SUPPORT. HVAC INSTALLATION SHALL BE INSTALLED ACCORDING TO ALL CURRENT STATE AND LOCAL MECHANICAL CODES. MECHANICAL DISCLAIMER 1/2" = 1'-0" BRACKET DETAIL 1 08/07/19 Mike Sheeks