HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance
Property Organization
7098 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: DURHAM Michael Hill
Community: THE GROVE AT LEGA[
Builder
GL0200B (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200E
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,189
$174
$333
$1,696
$662
$0
$2,358
Requirements
C-M,
Energy Solutions
As Designed
5973
5149
5333
$1,455
5662
s0
$2,117
C4405.3 Performance-based compliance passes by 14.2%
R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 11 -11 -Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 14.2%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
6113119 at 8:24 AM
Ekotrope RATER - Version 3.1.0.2194
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
7498 CHERRY CREEK BLVD
(CARMEL, IN 46033
Builder: li BUILDERS, LLC
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5ACH50
Window U-ValUe: 0.31, Sl 0.28
Building Features
Duct Supply R-13.0, Return R-9.0
Duct Leakage to Outside 97.0 CFM @ 251
Total Duct Leakage 570.0 CFM @ 251
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectetlrtested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC cr will be venfied as such by another party.
Name
Organization
Michael Hill
TSI Energy Solutions
Signature:
Date:
6113119 at 8:24 AM
Ekotrope RATER -Version 3.1.0.2194
2009 l compliance results calculated using Ekotrope RATER's energy and code camptance algorithm_
Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability forthe information sh— on this report.
Energy Code Inspection Checklist
Property Organization
7098 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: DURHAM Michael Hill
Community: THE GROVE AT LEGA(
GL0200B (AS DESIGNED)
THE GROVE AT LEGACY 200B
General Building Information
Conditioned Area (sq ft)
Conditioned Volume (cubic ft)
Insulated Shell Area (sq ft)
Builder
PYATT BUILDERS, LLC
2,601
22,608
6,215
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB (1,844 s.f.)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (1,740 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: III
El Name: CONDIGAR (410 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: III
Name: CONDIATTIC (7 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: III
Name: CONDICOND (370 s.f.)
R-0 continuous insulation, R-22 cavity insulation
Insulation Grade: III
Energy Code Inspection Checklist
Property
7098 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: DURHAM
Community: THE GROVE AT LEGA[
GL0200B (AS DESIGNED)
THE GROVE AT LEGACY 200E
Rim Joist
None Present
Roof
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Name: MAIN (1,844 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (20 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (158 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH
El Name: BACK (47 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH
El Name: SLIDER (64 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST
El Name: RIGHT (119 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
C-M,
Energy Solutions
Mechanical Equipment 2
Energy Code Inspection Checklist
Property Organization inspection Status
7098 CHERRY CREEK BLVD TSI Energy Solutions Results are projected
CARMEL, IN 46033 317-846-4655
Model: DURHAM Michael Hill
Community: THE GROVE AT LEGA(
Builder
GL0200B (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200B
El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
El Air conditioner • Electric • 100% Cooling Load @ 13 SEER
El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 1,876 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC. Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Tested Post -Construction
Leakage to Outdoors is specified in Ekotrope at 97.0 CFM @ 25Pa
Total Duct Leakage is specified in Ekotrope at 570.0 CFM @ 25Pa
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property Organization
7098 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: DURHAM Michael Hill
Community: THE GROVE AT LEGA(
Builder
GL0200B (AS DESIGNED) PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200B
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
7098 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: DURHAM
Community: THE GROVE AT LEGACY 200B
GLG200B [AS DESIGNED]
THE GROVE AT LEGACY 2008
Genera?Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Foundation Wall
Foundation Wall Library List
Slab
Organization Inspection Status
TSI Energy Solutions Results are projected
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
3
2
2;501
Yes
22;508
1
Duplex; single unit
DURHAM
THE GROVE AT LEGACY 200B
5A
None Present
None Present
Masonry Area
C-M,
Energy Solutions
n
SLAB R-10, 1'down, 2' in 215
On Grade 1.23
0 1,844.0 sq. R.
Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter
Perimeter
Thermal Break Effective R -value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft]
Insulation R Value
R-10, 1'down, 2' in Wood Frame /Other No
2 1
10
No 10.00
Framed Floor
None Present
1
Building Summary
Property
Organization
7098 CHERRY CREEK BLVD
TSI Energy Solutions
CARMEL, IN 46033
317-846-4655
Model: DURHAM
Michael Hill
Community: THE GROVE AT LEGACY 200B
Exposed Exterior
G3 R-15 BATT, OSB
Builder
GL0200B [AS DESIGNED]
PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200B
Framed Floor Library List
None Present
Rim Joist
Rim Joist Library List _
None Present
Wall
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library Type
Surface Calor
Surface Area
Location
CONDIAMB
Exposed Exterior
G3 R-15 BATT, OSB
Medium
1,740.0 sq. ft.
CONDIATTIC
Attic
G3 R-15 BATT, OSB
Medium
7.0 sq. ft.
CONDICOND
Conditioned Space [Adiabatic]
G3 R-22 Dbl Wall
Medium
370.0 sq. ft.
CONDIGAR
Unconditioned, attached garage
G3 R-15 Gar Walls
Medium
410.0 sq. H.
Wall Library List
Name
Effective R value
G3 R-15 BATT, OSB
12293
G3 R-15 Gar Walls
10.683
G3 R-22 Dhl Wall
15.364
2
Building Summary
Property Organization Inspection Status
7098 CHERRY CREEK BLVD TSI Energy Solutions Results are projected
CARMEL, IN 46033 317-846-4655
Model: DURHAM Michael Hill
Community: THE GROVE AT LEGACY 200B
Builder
GL❑200B [AS DESIGNED] PYATT BUILDERS, LLC
THE GROVE AT LEGACY 200B
FGlazin
Name Library Type WaIT Assignment Foundation Wall Overhang Depth Overhang Ft To
Assignment Top
Overhang Ft To
Bottom
C-MEnergy Solutions
Orientation Surface Area
BACK U-.31, SHGG28
CONDIAMB
❑
❑
❑
North
47.0 sq. ft
FRONT U-.31, SHGG28
CONDIAMB
❑
❑
❑
South
158.0 sq. ft.
RIGHT U-.31, SHGG28
CONDIAMB
0
❑
❑
East
119.0 sq. ft.
SLIDER U-.31, SHGG28
CONDIAMB
0
❑
❑
East
64.0 sq. ft
Glazing Library List
Name
Shg c
U #actor
U-.31, SHGC-28
028
0.31 ❑
Skylight
None Present
Skylight Library List
None Present
Opaque Door
Name Library Type Wall Assignment Foundation Wall
Emittance
Solar
Surface Color
Surface Area
Location
Assignment
Ab sorpta nce
FRONT Fiberglass Door
CONDIAMB
0.9
0.75
Medium
20.0 sq_ R
Exposed Exterior
GARAGE Fiberglass Door
CONDIGAR
09
075
Medium
18.0 sq_ ft
Exposed Exterior
Building Summary
Property
7098 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: DURHAM
Community: THE GROVE AT LEGACY 200B
GLG200B [AS DESIGNED]
THE GROVE AT LEGACY 200B
FOpaque Door Library List
Name
Fiberglass Door
Roof Insulation
Name
Library Typ
ktAIN
R-38 Blown. GRI
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Roof Insulation Library List
Name Has Radiant Barrier
R-38 Blown, GR1 No
Whole House Infiltration
Infiltration Measurement Type
I5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
Lighting
% Interior Fluorescent
Lighting
I 7s
0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
rArea Clay or Concrete Roof Surface Color Surface Area Location
Vt.] Tiles
7,844 No Medium 1,844.0 sq. ft Attic
None Present
38268
Shelter Class
4
or Fluorescent i. extenor I_eo Ligntmg -7G ioarage Fluorescent
Lighting Lighting
0
4
Building Summary
Property Organization
7098 CHERRY CREEK BLVD TSI Energy Solutions
CARMEL, IN 46033 317-846-4655
Model: DURHAM Michael Hill
Community: THE GROVE AT LEGACY 200B
Builder
GLD200B [AS DESIGNED] PYATT BUILDERS, LLC
THE GROVE AT LEGACY 20OB
nsite Generation
None Present
Onsite Generation Library List M
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipmenl
Name
Air conditioner
Fuel4red air
distribution
Water Heating
C-M
Energy Solutions
Inspection Status
Results are projected
g Percent Load Hot water
CA13 NA042 D% 1 DD%
9125A48080917 100% 0%
0%
0%
RE350" D% 0% 100%
Equipment Type: 912SA48080S17
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 78
Use default EAE No
EAE [kWh] 977
:j
Building Summary
Property
7098 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: DURHAM
Community: THE GROVE AT LEGACY 200B
GLG200B [AS DESIGNED]
THE GROVE AT LEGACY 2008
■
quipment Type: CA13NA042
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: RE350*
Fuel Type
Distribution Type
Hot Water Efficiency
Tank Capacity (gal.)
Hot Water Capacity [kBtulh]
Recovery Efficiency
Organization Inspection Status
TSI Energy Solutions Results are projected
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
s 7
Electric
Forced Air
PSC (Single Speed)
13 SEER
40
Electric
Hydronic Delivery
0.93 Energy Factor
50
15.4
0.98
C-M,
Energy Solutions
Building Summary
Property
7098 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: DURHAM
Community: THE GROVE AT LEGACY 200B
GL0200B [AS DESIGNED]
THE GROVE AT LEGACY 2008
1bution System
tion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area [sq. ft.]
]uct Area [sq. ft_]
akage to Outdoors (CFM25)
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Ctm Per Watt
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Forced Air
Fuel -fired air distribution
Air conditioner
2501
2
13
9
675.27
250.1
97
570
Post -Construction
Yes
Conditioned Space
30
30
Attic (well vented; under insulation)
65
40
Attic (well vented)
5
30
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
7098 CHERRY CREEK BLVD
CARMEL, IN 46033
Model: DURHAM
Community: THE GROVE AT LEGACY 200B
GLG200B [AS DESIGNED]
THE GROVE AT LEGACY 200B
ater Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
r
es Dryer
e
zation
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmabie thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
FV I
Organization
TSI Energy Solutions
317-846-4655
Michael Hill
Builder
PYATT BUILDERS, LLC
Standard
No
60
No
No
10
No
Electric
Timer Controls
704 kWh/Year
0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh/Year
Inspection Status
Results are projected
C-M,
Energy Solutions
,�