Loading...
HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property Organization 7098 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA[ Builder GL0200B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 200E Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,189 $174 $333 $1,696 $662 $0 $2,358 Requirements C-M, Energy Solutions As Designed 5973 5149 5333 $1,455 5662 s0 $2,117 C4405.3 Performance-based compliance passes by 14.2% R402.4.12 Air Leakage Testing Air sealing is 5 -DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 11 -11 -Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 14.2%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 6113119 at 8:24 AM Ekotrope RATER - Version 3.1.0.2194 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 7498 CHERRY CREEK BLVD (CARMEL, IN 46033 Builder: li BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5ACH50 Window U-ValUe: 0.31, Sl 0.28 Building Features Duct Supply R-13.0, Return R-9.0 Duct Leakage to Outside 97.0 CFM @ 251 Total Duct Leakage 570.0 CFM @ 251 Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports. I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected. I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed. I certify that the address referenced above has been inspectetlrtested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC cr will be venfied as such by another party. Name Organization Michael Hill TSI Energy Solutions Signature: Date: 6113119 at 8:24 AM Ekotrope RATER -Version 3.1.0.2194 2009 l compliance results calculated using Ekotrope RATER's energy and code camptance algorithm_ Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability forthe information sh— on this report. Energy Code Inspection Checklist Property Organization 7098 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( GL0200B (AS DESIGNED) THE GROVE AT LEGACY 200B General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Builder PYATT BUILDERS, LLC 2,601 22,608 6,215 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,844 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (1,740 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III El Name: CONDIGAR (410 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Name: CONDIATTIC (7 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: III Name: CONDICOND (370 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: III Energy Code Inspection Checklist Property 7098 CHERRY CREEK BLVD CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGA[ GL0200B (AS DESIGNED) THE GROVE AT LEGACY 200E Rim Joist None Present Roof Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Name: MAIN (1,844 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (158 s.f.), U:0.310, SHGC: 0.28, Orientation: SOUTH El Name: BACK (47 s.f.), U:0.310, SHGC: 0.28, Orientation: NORTH El Name: SLIDER (64 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST El Name: RIGHT (119 s.f.), U:0.310, SHGC: 0.28, Orientation: EAST Skylight None Present Mechanical Ventilation None Present C-M, Energy Solutions Mechanical Equipment 2 Energy Code Inspection Checklist Property Organization inspection Status 7098 CHERRY CREEK BLVD TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( Builder GL0200B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 200B El Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER El Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 1,876 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC. Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 97.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 570.0 CFM @ 25Pa C", Energy Solutions 3 Energy Code Inspection Checklist Property Organization 7098 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGA( Builder GL0200B (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 200B Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 7098 CHERRY CREEK BLVD CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 200B GLG200B [AS DESIGNED] THE GROVE AT LEGACY 2008 Genera?Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 3 2 2;501 Yes 22;508 1 Duplex; single unit DURHAM THE GROVE AT LEGACY 200B 5A None Present None Present Masonry Area C-M, Energy Solutions n SLAB R-10, 1'down, 2' in 215 On Grade 1.23 0 1,844.0 sq. R. Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, 2' in Wood Frame /Other No 2 1 10 No 10.00 Framed Floor None Present 1 Building Summary Property Organization 7098 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGACY 200B Exposed Exterior G3 R-15 BATT, OSB Builder GL0200B [AS DESIGNED] PYATT BUILDERS, LLC THE GROVE AT LEGACY 200B Framed Floor Library List None Present Rim Joist Rim Joist Library List _ None Present Wall Inspection Status Results are projected C-M, Energy Solutions Name Library Type Surface Calor Surface Area Location CONDIAMB Exposed Exterior G3 R-15 BATT, OSB Medium 1,740.0 sq. ft. CONDIATTIC Attic G3 R-15 BATT, OSB Medium 7.0 sq. ft. CONDICOND Conditioned Space [Adiabatic] G3 R-22 Dbl Wall Medium 370.0 sq. ft. CONDIGAR Unconditioned, attached garage G3 R-15 Gar Walls Medium 410.0 sq. H. Wall Library List Name Effective R value G3 R-15 BATT, OSB 12293 G3 R-15 Gar Walls 10.683 G3 R-22 Dhl Wall 15.364 2 Building Summary Property Organization Inspection Status 7098 CHERRY CREEK BLVD TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGACY 200B Builder GL❑200B [AS DESIGNED] PYATT BUILDERS, LLC THE GROVE AT LEGACY 200B FGlazin Name Library Type WaIT Assignment Foundation Wall Overhang Depth Overhang Ft To Assignment Top Overhang Ft To Bottom C-MEnergy Solutions Orientation Surface Area BACK U-.31, SHGG28 CONDIAMB ❑ ❑ ❑ North 47.0 sq. ft FRONT U-.31, SHGG28 CONDIAMB ❑ ❑ ❑ South 158.0 sq. ft. RIGHT U-.31, SHGG28 CONDIAMB 0 ❑ ❑ East 119.0 sq. ft. SLIDER U-.31, SHGG28 CONDIAMB 0 ❑ ❑ East 64.0 sq. ft Glazing Library List Name Shg c U #actor U-.31, SHGC-28 028 0.31 ❑ Skylight None Present Skylight Library List None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Fiberglass Door CONDIAMB 0.9 0.75 Medium 20.0 sq_ R Exposed Exterior GARAGE Fiberglass Door CONDIGAR 09 075 Medium 18.0 sq_ ft Exposed Exterior Building Summary Property 7098 CHERRY CREEK BLVD CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 200B GLG200B [AS DESIGNED] THE GROVE AT LEGACY 200B FOpaque Door Library List Name Fiberglass Door Roof Insulation Name Library Typ ktAIN R-38 Blown. GRI Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Roof Insulation Library List Name Has Radiant Barrier R-38 Blown, GR1 No Whole House Infiltration Infiltration Measurement Type I5 ACH at 50 Pa Blower -door tested Mechanical Ventilation Lighting % Interior Fluorescent Lighting I 7s 0.182 Inspection Status Results are projected C-M, Energy Solutions rArea Clay or Concrete Roof Surface Color Surface Area Location Vt.] Tiles 7,844 No Medium 1,844.0 sq. ft Attic None Present 38268 Shelter Class 4 or Fluorescent i. extenor I_eo Ligntmg -7G ioarage Fluorescent Lighting Lighting 0 4 Building Summary Property Organization 7098 CHERRY CREEK BLVD TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: DURHAM Michael Hill Community: THE GROVE AT LEGACY 200B Builder GLD200B [AS DESIGNED] PYATT BUILDERS, LLC THE GROVE AT LEGACY 20OB nsite Generation None Present Onsite Generation Library List M None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipmenl Name Air conditioner Fuel4red air distribution Water Heating C-M Energy Solutions Inspection Status Results are projected g Percent Load Hot water CA13 NA042 D% 1 DD% 9125A48080917 100% 0% 0% 0% RE350" D% 0% 100% Equipment Type: 912SA48080S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 78 Use default EAE No EAE [kWh] 977 :j Building Summary Property 7098 CHERRY CREEK BLVD CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 200B GLG200B [AS DESIGNED] THE GROVE AT LEGACY 2008 ■ quipment Type: CA13NA042 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC s 7 Electric Forced Air PSC (Single Speed) 13 SEER 40 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property 7098 CHERRY CREEK BLVD CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 200B GL0200B [AS DESIGNED] THE GROVE AT LEGACY 2008 1bution System tion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area [sq. ft.] ]uct Area [sq. ft_] akage to Outdoors (CFM25) akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Ctm Per Watt Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Forced Air Fuel -fired air distribution Air conditioner 2501 2 13 9 675.27 250.1 97 570 Post -Construction Yes Conditioned Space 30 30 Attic (well vented; under insulation) 65 40 Attic (well vented) 5 30 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 7098 CHERRY CREEK BLVD CARMEL, IN 46033 Model: DURHAM Community: THE GROVE AT LEGACY 200B GLG200B [AS DESIGNED] THE GROVE AT LEGACY 200B ater Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? r es Dryer e zation Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmabie thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption FV I Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Standard No 60 No No 10 No Electric Timer Controls 704 kWh/Year 0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year Inspection Status Results are projected C-M, Energy Solutions ,�