Loading...
HomeMy WebLinkAboutM001.0IECC 2009 Performance Compliance Property Organization 7113 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SAUSALITO Michael Hill Community: THE GROVE AT LEGA( Builder GL188A(AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $888 $129 $263 $1,280 $635 $0 $1,915 Requirements C", Energy Solutions As Designed $817 $154 $263 $1,233 $628 $0 $1,861 Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3.6%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectecnested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 6117119 at 9:22 PM Ekotrope RATER - Version 3.1.0.2196 IECC 2009 Performance compliance results calculated using Ekotrope RATER's anergy and code compliance algorithm. Ekotrope RATER is a RESNr7T Aocred ited HERS Rating Tool. All resuis are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the in for m atio n s how n on this report. 405.3 Performance-based compliance passes by 3.6% R402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration 5HGC 402.5 Area -weighted average fenestration U -Factor 403.2.2 Duct Testing Q Mandatary Checklist Mandatory code requirements that are not checked by Ekotrope must be met. Q R405.2 Duct Insulation C", Energy Solutions As Designed $817 $154 $263 $1,233 $628 $0 $1,861 Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 3.6%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Cade based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectecnested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 6117119 at 9:22 PM Ekotrope RATER - Version 3.1.0.2196 IECC 2009 Performance compliance results calculated using Ekotrope RATER's anergy and code compliance algorithm. Ekotrope RATER is a RESNr7T Aocred ited HERS Rating Tool. All resuis are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the in for m atio n s how n on this report. 7113 Antiquity Dr CARMEL, IN 46033 Builder: PYATT BUILDERS, LLC Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U -Value: 0.31, SHGC: 0.32 Building Features Duct Supply R-25.0, Return R-25.0 Duct Leakage to Outside 96.0 CFM @ 25Pa Total Duct Leakage 128.0 CFM @ 25Pa Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter Q of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Organization: Michael Hill TSI Energy Solutions Signature: Date: 6117119 at 9:22 PM Ekotrope RATER - Version 3.1.0.2196 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETA—sdlted HERS Rating Tool. All results are based on data entered by Ekotrope users, Ekotrope disclaims all liability forthe information shown on this report. Energy Code Inspection Checklist Property Organization 7113 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SAUSALITO Michael Hill Community: THE GROVE AT LEGA( GL188A(AS DESIGNED) THE GROVE AT LEGACY 188A General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Builder PYATT BUILDERS, LLC 1,647 15,349 5,724 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (1,647 s.f.) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall Name: COND/AMB (1,566 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: COND/GAR (378 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: COND/COND (387 s.f.) R-0 continuous insulation, R-22 cavity insulation Insulation Grade: I Name: COND/ATTIC (99 s.f.) R-3 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property 7113 Antiquity Dr CARMEL, IN 46033 Model: SAUSALITO Community: THE GROVE AT LEGA( GL188A(AS DESIGNED) THE GROVE AT LEGACY 188A Rim Joist None Present Roof Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Name: MAIN (1,647 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (20 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (80 s.f.), U: 0.310, SHGC: 0.32, Orientation: NORTH El Name: BACK (59 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH El Name: SLIDER (128 s.f.), U:0.310, SHGC: 0.32, Orientation: SOUTH El Name: LEFT SIDE (141 s.f.), U:0.310, SHGC: 0.32, Orientation: WEST Name: RIGHT SIDE (83 s.f.), U:0.310, SHGC: 0.32, Orientation: EAST Skylight None Present Mechanical Ventilation C"IEnergySdutions 2 Energy Code Inspection Checklist Property Organization Inspection Status 7113 Antiquity Dr TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: SAUSALITO Michael Hill Community: THE GROVE AT LEGA( Builder G1_188A(AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrslday, 9 Watts. Mechanical Equipment L Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE 0 Air conditioner • Electric • 100% Cooling Load @ 13 SEER Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 1,279 CFM50 (5,00 ACH50) or less at final blower -door test, Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Tested Post -Construction Leakage to Outdoors is specified in Ekotrope at 96.0 CFM @ 25Pa Total Duct Leakage is specified in Ekotrope at 128.0 CFM 9 25Pa C", Energy Solutions Energy Code Inspection Checklist Property Organization 7113 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Model: SAUSALITO Michael Hill Community: THE GROVE AT LEGA( Builder GL188A(AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A Duct Leakage Code Requirements for IECC 9009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM95 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM95 1100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM95 1100 sq ft CFA. 9019 IECC and 9015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM95 1 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM95 1100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM95 1100 sq ft CFA. 9015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Pro perty 7113 Antiquity Dr CARMEL, IN 45033 Madel: SAUSALITO Community: THE GROVE AT LEGACY 188A GLI 88A (AS DESIGNED) THE GROVE AT LEGACY 186A General Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq. ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC 2 1 1,647 Yes 15,349 1 Duplex, single unit SAUSALITO THE GROVE AT LEGACY 188A 5A None Present Foundation Wall Library List None Present Inspection Status Results are projected CTMEnergy Solutions Slab Ew— 9 0 Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area SLAB R-10, 2'down,2' in 215 On Grade 1.23 0 1,647.0 sq. ft. Exposed Exterior Conditioned Space Slab Library L—is!A��� 9 Name Wall Construction Slab Completely Llndersiab Perimeter Perimeter Thermal Break Effective R -value Type Insulated. Insulation Width [ft] Insulation Depth (ft] Insulation R Value R-10, 2'down, 2' in Wood Frame f Other No 2 2 10 No 1D.00 Framed Floor rM None Present 1 Building Summary Property Organization 7113 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Madel: SAUSALITO Michael Hill Community: THE GROVE AT LEGACY 188A Surface Color Surface Area Builder GLI 88A (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A Framed Floor Library List E&M G1 R-15 BATT, OSB None Present Rim Joist 1,566.D sq. It. CONDIATTIC None Present Rim Joist Library List None Present CTMEnergy Solutions Inspection Status Results are projected Wall ■ Name Library Type Surface Color Surface Area Location CCNDIAMB Exposed Exterior G1 R-15 BATT, OSB Medium 1,566.D sq. It. CONDIATTIC Attic 01 R-15 BATT, R,3.0 Medium 99.D sq. It. CONDICOND Conditioned Space (Adiabatic) Gi R-22 Dbl Wall Medium 387.0 sq. ft. CONDIGAR Unconditioned, attached garage G1 R-15 Gar Walls Medium 378.0 sq. ft. Wall Library List Name Effective R -value G1 R-15 BATT, OSB 13.423 G1 R-15 BATT, R-3.0 16.138 G7 R-15 Gar Walls 11.972 07 R-22 Dbl Wall 18.407 2 Building Summary Property Organization Inspection Status CTMEnergy Solutions 7113 Antiquity Dr TSI Energy Solutions Results are projected CARMEL, IN 45033 317-846-4655 Madel: SAUSALITO Michael Hill Community: THE GROVE AT LEGACY 188A Builder GLI 88A (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A Glazing Name Library Type Wall Assignment Foundation Wall Overhang Assignment Depth Overhang Ft Top To Overhang Ft To Bottom Orientation Surface Area BACK U-.31, SHGC-.32 South 59.0 sq. ft. CONDIAMB ❑ 0 ❑ FRONT U-.31, SHGC-.32 North 80.0 sq. ft. CONDIAMB ❑ 0 ❑ LEFT SIDE U-.31, SHGC-.32 West 1D1.0sq. ft. CONDIAMB ❑ 0 ❑ RIGHT SIDE U-.31, SHGC-.32 East 83.0 sq. ft. CONDIAMB 0 0 ❑ SLIDER U-.31, SHGC-.32 South 128.0 sq. ft. CONDIAMB 0 0 0 Glazing Library List Name Shgc LI -factor U-.31, SHGC-.32 0.32 0.31D Skylight —Mw None Present Skylight Library List MEOW None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Abso rptan ce FRONT Steel Door CONDIAMB 0.9 D.75 Medium 2D.0 sq. ft. Exposed Exterior GARAGE Steal Door CONDIGAR 0.9 0.75 Medium 18.0 sq. ft. Exposed Exterior 3 Building Summary Property Organization 7113 Antiquity Dr TSI Energy Solutions CARMEL, IN 46033 317-846-4655 Madel: SAUSALITO Michael Hill Community: THE GROVE AT LEGACY 188A Builder GLI 88A (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A Opaque Door Library List Name Effective 1.1 -factor Steel Door 0.182 Roof Insulation Name MAIN R-38 Blown, GRI Inspection Status Results are projected CTMEnergy Solutions 1,647 No Medium 1,647.0 sq. ft. Attic Roof Insulation Library List Name Has Radiant Barrier Effective R -value R-38 Blown, GRI No 38.268 Whole House Infiltration Infiltration Measure me nt Type She I to r C lass 5 ACH at 50 Pa Blower -door tasted 4 I Mechanical Ventilation Ventilation Type Ventilation Rate [Cubic Feet Operational hours per day Fan Watts Runs once every three Energy Recovery percent /Mlnuta] hours Exhaust Only 20 24 9 Yes 0 Lighting % Interior Fluorescent Lighting 0 ❑ ❑ ❑ ❑ 0 4 Building Summary Pro perty 7113 Antiquity Dr CARMEL, IN 46033 Model: SAUSALITO Community: THE GROVE AT LEGACY 188A GLI 88A (AS DESIGNED) THE GROVE AT LEGACY 186A Onsite Generation Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC None Present Onsite Generation Library List None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Name Air conditioner Fuel -fired air distribution Water Heating CA13NA048 912SA4806DS17 ENT 50 100 Equipment Type: 912SA4806OS17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG [Single Speed] Heating Efficiency 92.1 AFUE Heating Capacity [kBtufh] 56 Use default EAE No EAE [kWh] 649 Inspection Status Results are projected 0% 100% 0% ng Percent wat 100% 0% 4% CTMEnergy Solutions 0°% VI6 100% .7 Building Summary Pro perty 7113 Antiquity Dr CARMEL, IN 45033 Model: SAUSALITO Community: THE GROVE AT LEGACY 188A GLI 88A (AS DESIGNED) THE GROVE AT LEGACY 186A Equipment Type: CA13NA048 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] q ' Equipment Type: ENT 50100 Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Electric Forced Air PSC (Single Speed) 13 SEER 45.5 Inspection Status Results are projected Fuel Type Electric Distribution Type Hydranic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtu/h] 15.4 Recovery Efficiency 0.98 CTMEnergy Solutions Building Summary Property Organization Inspection Status 7113 Antiquity Dr TSI Energy Solutions Results are projected CARMEL, IN 46033 317-846-4655 Model: SAUSALITO Michael Hill Community: THE GROVE AT LEGACY 188A 1 Supply Duct R Value Builder GLI 88A (AS DESIGNED) PYATT BUILDERS, LLC THE GROVE AT LEGACY 188A 444.69 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 1647 # Return Grilles 1 Supply Duct R Value 25 Return Duct R Value 25 Supply Duct Area [sq. ft.] 444.69 Retum Duet Area [sq. ft.] 82.35 Duct Leakage to Outdoors (CFIM 25) 96 Total Leakage 128 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 5 Percent Return Area 5 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area 95 Percent Return Area 95 Duct 3 Duct Location Attic (well vented) Percent Supply Area 6 Percent Return Area t? Duct 4 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Ceiling Fan Has Ceiling Fan No Cfm Per Watt 100 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Standard No 25 No No 10 No CTMEnergy Solutions VA Building Summary Pro perty 7113 Antiquity Dr CARMEL, IN 46033 Model: SAUSALITO Community: THE GROVE AT LEGACY 188A GLI 88A (AS DESIGNED) THE GROVE AT LEGACY 188A Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption NMS Organization TSI E nerg y S olution s 317-846-4655 Michael Hill Builder PYATT BUILDERS, LLC Electric 2.617 Timer Controls 704 kWhNear $0.08/kWh $23.00 $0.581Therm 2.874 0.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year Inspection Status Results are projected CTMEnergy Solutions